BeamTherapyEquipment射束治疗设备

上传人:e****s 文档编号:252476370 上传时间:2024-11-16 格式:PPT 页数:15 大小:392.50KB
返回 下载 相关 举报
BeamTherapyEquipment射束治疗设备_第1页
第1页 / 共15页
BeamTherapyEquipment射束治疗设备_第2页
第2页 / 共15页
BeamTherapyEquipment射束治疗设备_第3页
第3页 / 共15页
点击查看更多>>
资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,Beam Therapy Equipment,2 Linear Accelerator Head,Photon/Electron differences,Target,Flattening filter,Any jaw size,MLCs,Shaping blocks,Intensity modulation e.g.wedges,No target,Scattering foils,Jaw size dependent on energy and applicator,e,-,applicator,End-frame,No intensity modulation,Photon Head,Electron Head,Changes to accelerator when using electrons-automatic,Photon target is moved out of the way.,Carousel is moved to position scattering foil for particular electron energy in place of photon flattening filter.,Gun volts on electron gun are reduced to decrease the number of electrons passing through wave guide.,Frequency of rf adjusted to give optimum acceleration of electrons,Bending magnet voltages adjusted to finely tune electron energies leaving bending magnet,Changes to accelerator when using electrons manual,Jaws moved to pre-defined position dependent on applicator size and electron energy.Optimised for flat field(wide scattering),Electron applicator attached to head,Electron insert fitted into end of applicator defines final field size,Scattering foils,Scattering foils chosen for wide scattering angle(flat field),energy loss(none)and bremsstrahlung production(none),Usually made of copper,Not necessarily of uniform thickness,Higher electron energies may use two foils,Electron field shaping,Electrons are scattered by air between scattering foils and patient,therefore final shaping needs to be done as close to patient as possible,Shaping done by:,Secondary collimators coarse,Electron trimmers scrape scattered electrons,Electron insert fine field shape,Applicators,Applicator consists of progressively smaller scrapers,Electrons scattered by foil have a Gaussian distribution,electrons scattered by scrapers are used to flatten the beam,Scrapers should be made of low Z material(Aluminium)to limit X-ray production,Safety Devices,The scattering foil,secondary collimator settings,bending magnet voltages are checked for consistency with energy/applicator selected.,Presence of the applicator and correct insert may be interlocked.(Applicator interlock very common,insert interlock rare),Collision of applicator with patient,bed etc is also checked using sensors built into applicator.,Radiation symmetry,output and energy are monitored by the monitor chamber during treatment,Beam shaping,Beam can be modified in 3D shape and intensity,Collimators,Applicators,MLCs,Cast blocks,Wedges,Penumbra,MLC,Used to shape radiation field,Can interdigitate,Fields set automatically,52 160 leaves,Typically 60mm tall,2.5%leaf transmission;4%interleaf leakage,Tongue and groove offset,Focused in 1 direction,7mm penumbra,Blocks vs.MLCs,BLOCKs,Exact shape,Move small amounts,Easy to check on patient,Heavy,Facing right way,Individual possibility of using wrong block,MLCs,Stepped,Movement need re-plan,Difficult to check on patient,Auto set-up,Individual attached to field,Wedges to shape the radiation beam,Hard Usually lead,manually placed in accessory mount,range of angles available.Increase energy of primary and dose from scattered,Universal Single 60,Wedge in treatment head,mixed with open field to get intermediate angles.,Increase energy of primary and dose from scattered,Dynamic formed by sweeping one of the jaws across the radiation field,range of angles available.Primary same energy,Penumbra,Energy,Radiation,Source size,
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 商业管理 > 商业计划


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!