单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,三相异步电动机的,降压启动控制线路,全压启动:启动时加在电动机定子绕组上的电压为电动机的额定电压。,降压启动:利用启动设备将电压适当降低后,加到电动机的定子绕组上进行启动,待电动机启动运转后,再使其电压恢复到额定电压正常运转。,电动机的直接启动条件:,三相异步电动机的全压启动:启动时加在电动机定子绕组上的电压为,1,电动机启动时,把电动机的定子绕组接成,星形,电动机定子绕组电压低于电源电压起,动,启动即将完毕时再恢复成三角形,电动机,便在额定电压下正常运行。,Y,降压启动控制线路,电动机启动时,把电动机的定子绕组接成Y降压启动控制线,2,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,电路组成分析,KM,Y,KT,M,3,KH,KH,时间继电器自动控制,Y,降压启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,3,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,合上电源开关,QS,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,4,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,降压启动,:,按下,SB1,KT,线圈得电,KM,Y,线圈得电,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,Y-降压,启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,5,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,KM,Y,主触头闭合,KM,Y,动合辅助触头闭合,KM,Y,动断辅助触头断开,KM,自锁触头闭合,KM,主触头闭合,电动机降压启动,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,6,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,松开,SB1,电动机继续,降压启动,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,7,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,KT,延时断开的动断触头延时分断,KM,Y,线圈失电,KM,Y,主触头断开,KM,Y,动合辅助触头断开,KM,Y,动断辅助触头闭合,KM,主触头闭合,KM,动断辅助触头断开,KT,线圈失电,电动机全压运行,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,8,L1L2L3,FU1,FU2,KM,KM,SB1,SB2,KM,U,V,W,QS,KM,Y,KM,KM,Y,KM,KM,Y,KT,KM,停,:,按下,SB2,KM,Y,KT,M,3,KH,KH,2.,时间继电器自动控制,Y,降压启动控制线路,Y-降压,启动控制线路,L1L2L3FU1FU2KMKMSB1SB2KMUVWQS,9,启动时,把定子三相绕组的一部分联接成三,角形,另一部分联接成星形,每相绕组上所承受,的电压,比三角形联接时的相电压要低,比星形,联接时的相电压要高,电动机延边三角形降压,启动,,,待电动机启动运转后,再将绕组联接三角,形,全压运行。,四、延边,降压启动控制线路,启动时,把定子三相绕组的一部分联接成三四、延边降压启,10,延边三角形降压启动电动机定子绕组的联接方式,原始状态,U1,U2,U3,W3,W1,W2,V2,V3,V1,延边三角形降压启动电动机定子绕组的联接方式原始状态U1U2U,11,延边三角形降压启动电动机定子绕组的联接方式,启动时,U1,U2,U3,W3,W1,W2,V2,V3,V1,延边三角形降压启动电动机定子绕组的联接方式启动时U1U2U3,12,延边三角形降压启动电动机定子绕组的联接方式,正常运转时,U1,U2,U3,W3,W1,W2,V2,V3,V1,延边三角形降压启动电动机定子绕组的联接方式正常运转时U1U2,13,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,延边三角形降压启动控制原理,L1L2L3,FU1,FU2,KH,KM1,KM,2,U1,V1,W1,QS,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,电路组成分析,M,3,KTKM2SB2KM3KM1KTSB1KM2延边三角形降压启,14,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,FU1,FU2,KH,KM1,KM,2,U1,V1,W1,QS,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,合上电源开关,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3FU,15,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,按,SB2 KM3,线圈得电,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,16,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,KM3,联锁触头分断,对,KM2,联锁,KM3,主触头闭合 联结成延边三角形,KM,动合辅助触头闭合,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,17,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,KM1,线圈得电,KM1,自锁触头闭合,自锁,松开,SB2 KM1,主触头闭合,电动机延边三角形降压启动,KT,线圈得电,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,18,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KT,线圈得电,KT,延时断开的动断触头延时分断, KM3,线圈失电,KT,延时闭合的动合触头延时闭合,,KM2,线圈得电,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,19,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,线圈失电,KM3,动合触头分断,,KM3,主触头分断,电动机失电惯性运行,KM2,线圈得电,KM2,自锁触头闭合,自锁,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,20,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,KH,KM1,KM,2,U1,V1,W1,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM2,主触头闭合,电动机全电运行,KM2,联锁触头断开,,KT,线圈失电,KT,触头复位,KM3,FU1,FU2,QS,延边三角形降压启动控制原理,M,3,KTKM2SB2KM3KM1KTSB1KM2L1L2L3KH,21,KT,KM2,SB2,KM3,KM1,KT,SB1,KM2,L1L2L3,FU1,FU2,KH,KM1,KM,2,U1,V1,W1,QS,KM1,KM2,W3,U3,V3,KH,3,W2,U2,V2,KM3,KT,KM3,KM3,停,:,按下,SB1,延边三角形降压启动控制原理,M,3,以上控制线路和教材中图,246,所示延边三角形降压启动控制线路有哪些相同点和不同点?,KTKM2SB2KM3KM1KTSB1KM2L1L2L3FU,22,1.,主要特点:,全数字自动控制;,启动电流小,启动转矩大、平稳;,启动参数可根据负载类型任意调整;,可连续、频繁启动;可分别启动多台电机;,具有完善、可靠的保护功能。,五、固态启动器,1.主要特点:五、固态启动器,23,2.,工作特性,斜坡恒流启动 脉冲阶跃启动,2.工作特性斜坡恒流启动,24,
展开阅读全文