毕业设计(论文)北京某小区某号楼高层住宅楼的建筑给水系统设计

上传人:1777****777 文档编号:39233981 上传时间:2021-11-10 格式:DOC 页数:26 大小:1.16MB
返回 下载 相关 举报
毕业设计(论文)北京某小区某号楼高层住宅楼的建筑给水系统设计_第1页
第1页 / 共26页
毕业设计(论文)北京某小区某号楼高层住宅楼的建筑给水系统设计_第2页
第2页 / 共26页
毕业设计(论文)北京某小区某号楼高层住宅楼的建筑给水系统设计_第3页
第3页 / 共26页
点击查看更多>>
资源描述
徐州工业职业技术学院 毕业设计(论文)题 目: 年级专业: 学生姓名: 学 号: 指导教师: 职 称: 导师单位: 摘要在综合对比分析的基础上,设计了北京某小区某号楼高层住宅楼的建筑给水系统、建筑排水系统、建筑消防系统设计。给水系统采用分区供水,低区一到三层,由市政给水管网直接供水;高区四到十二层,采用无负压变频供水。排水系统采用污、废水分流制,一层单独排放,排水立管设伸顶通气管,污水经化粪池处理后排向市政污水管网。消防系统为消防栓给水系统,采用水泵水箱联合供水。给水管采用PP-R管;排水管采用UPVC管;消防系统采用钢管。关键词:高层建筑;给水系统;排水系统;消防系统ABSTRACTBaised on the synthesis analysis, the water supply system, the drainage system, fire system and roof drainage system for the tenth high complex building of Lu Neng Jin Xiu Cheng are designed.The water supply system is applied by vertical division block. The floors from the first to the third are the low areas, water of which is supplied directly by the municipal pipe network. The floors from the 4th to the 19th are the high areas, water of which is supplied with the frequency conversion pump group. The drainage system is an interflow system of sewerage and waste water. Water of the first floor drains separately, the upright draining pipes are equipped with the ventilating pipes, and then the sewerage is disposed by the septic tanks and drains to the municipal waste pipe network. The fire system includes the fire hydrant system and automatic sprinkler system. The water supply pipes and drainage pipes are made of the PP- R pipes and the UPVC pipes respectively, and the material of the fire fighting system is made of steel pipes.Key Words: high building;water supply system;wastewater system;fire system工程概况方案比选及说明1 前 言本次设计的目的是充分利用所学的现有的知识,完成高层建筑给水排水工程的设计。此次设计基本上实现了我们从理论知识向实际工程设计的转变,充分的把理论知识应用到实际的工程当中,并对设计的方案、内容加以有针对性地、有说服力地论证,从而实现设计工程的可行性。本次设计在选题的过程中,考虑到地区性、建筑性质,选用高层建筑,建筑类别相对高级,进行建筑给水排水工程的设计,满足人们的生活需要,并且使人们得到舒适、便利生活环境。设计的大体内容是:建筑给水工程、排水工程和消防工程,设计的意义在于满足人们生活用水的同时,要满足室内的消防用水,保证人们居住的安全性。设计的依据为相关书籍和设计手册、规范。在设计中,大都按照常规方法,严格依据设计规范来进行,建筑给水排水系统及卫生设备要相对完善,在技术上要保持先进的水平,在计算的过程中,尽量使用符合经济流速的管径,以便降低成本,同时要考虑水的漏失、压力情况来选择管材和一些连接管件,以便在水从市政管网输送到建筑内用户的过程中,水的漏失量最少,节约水资源。1.1国内外高层建筑给水排水工程设计研究的状况和主要内容高层建筑给水排水工程与一般多层建筑和低层建筑给水排水工程相比,基本理论和计算方法在某些方面是相同的,但因高层建筑层数多、建筑高度大、建筑功能广、建筑结构复杂,以及所受外界条件的限制等,高层建筑给水排水工程无论是在技术深度上,还是广度上,都超过了低层建筑物的给水排水工程的范畴,并且有以下一些特点高层建筑给水排水设备的使用人数多,瞬时的给水量和排水流量靠的水源,以及经济合理的给水排水系统形式,并妥善处理排水管道的通气问题,以保证供水安全可靠、排水通畅和维护管理方便。下面就高层建筑给水排水工程的主要特点介绍如下:。高层建筑的功能复杂,失火可能性大,失火后蔓延迅速,人员疏散及扑救困难。为此,必须设置安全可靠的室内消防给水系统,满足各类消防的要求,而且消防给水的设计应“立足自救”,方可保证及时扑灭火灾,防止重大事故发生。高层建筑对防噪声、防震等要求较高,但室内管道及设备种类繁多、管线长、噪声源和震源多,必须考虑管道的防震、防沉降、防噪声、防水锤、防管道伸缩变位、防压力过高等措施。以保证管道不漏水,不损坏建筑结构及装饰,不影响周围环境,使系统安全运行。1.2国内外高层建筑给水排水工程设计研究的状况和主要内容1.2.1高层建筑给水排水工程设计方法近年来,随着高层建筑业的快速发展,建筑给水排水工程设计方法也有了不少的改进和更新。高层建筑生活给水首先,对适用于高层建筑的生活给水设计秒流量计算方法的研究,一直不断地在进行。经验法,概率法,平方根法等计算方法不断地被修正和改进。用科学的概率法取代现在仍在使用的平方根法,研究人员在此方面进行了不少尝试。其次,变频恒压调速供水技术日益成熟,加上减压阀的使用,改善了原来高层建筑“水箱一水泵联合供水”和“水箱减压”方法中出现的“水质二次污染”和“水箱占用大量建筑面积”的状况,同时也达到了节能效果。再次,在贮水方面,合建水箱的设计方式己越来越少的被采用,取而代之的是生活水池与消防水池分建的设计方式,其中,生活水池也大多倾向于采用不锈钢板等组合式水箱。高层建筑消防给水首先,因为高层建筑的消防特点是“立足于自救”。新的规范对设置场所危险等级、设计基本参数、管道水力计算等方面都作出了一些调整。这些调整都是注入了广大设计人员近年来工作研究实践得出的宝贵经验,以及借签了国外工程设计经验的结果。消火栓给水系统也在变频分级供水方面进行的有益的尝试和应用。另外,为保障高层建筑火灾初期消防水压及水量而设计的稳高压系统,先从上海地区得到应用,然后逐步在各地推广开来,其计算及设计手段逐渐成熟,乃至有人建议将稳高压消防给水系统单独列入高层民用建筑设计防火规范以区别原有的常高压消防给水系统和临时高压消防给水系统。高层建筑排水排水的输送已不限于重力流和压力流,虹吸流出现在压力(虹吸)式屋面雨水排水系统。排水塑料管的噪声防治问题上,或采用改变水流状态的方法、或采用改变管道结构型式、或兼用两种方式,都有一定效果。1.2.2高层建筑给水排水设计的主要内容建筑也迅猛发展,各项工程设计内容丰富。高层建筑给水排水设计的主要内容有:给水工程设计的主要内容高层建筑给水工程设计的主要内容有:用水量计算,给水方式的确定,管道设备的布置,管道的水力计算及室内所需水压的计算,水池、水箱的容积确定和构造尺寸确定,水泵的流量、扬程及型号的确定,管道设备的材料及型号的选用,施工图的绘制和施工要求。室内消防设计的主要内容高层建筑室内消防设计的主要内容有:消火栓系统,自动喷水灭火系统,二氧化碳灭火系统,干粉灭火系统,卤代烷灭火系统(现已不让采用),蒸汽灭火系统,烟雾灭火系统等。以水作为灭火剂的主要有消火栓系统和自动喷水灭火系统。消火栓给水系统设计包括消防用水量的确定:消防给水方式确定:消防栓的位置、消防栓的个数和型号确定;消防水池、水箱的容积确定;消防管道的水力计算及消防水压的计算;消防水泵的流量、扬程、型号和稳压系统的确定;消防控制系统的确定:消火栓给水系统的施工图绘制及施工要求。 排水工程设计的主要内容高层建筑排水工程设计内容包括:排水体制的确定,排水方案的确定,排水管道系统的布置,排水管道的水力计算及排水通气系统的计算,卫生设备的选型及布置,局部污水处理,构筑物的选型,屋面雨水排水系统的确定,排水管材的定型,排水系统施工图的绘制和施工要求。2 工程概况及设计任务2.1 工程概况2.2设计资料2.2.1 建筑设计资料 建筑物一层平面图、首层平面图、二层平面图、标准层平面图、十一层平面图、屋顶平面图2.2.2 城市给水排水设计资料1:该楼位于济南市区,该地区工程地质条件良好,室外地面标高38.00m。2:市政给水管网提供的最小、最大工作压力分别是280kp、500kp。3:室外给水管西、北各一条,管径均为300mm,管中心距地面均为1.0m。流量65L/S2.3 工程设计任务在本次设计中,要求设计的该建筑的给水排水工程的内容如下:(1)建筑给水工程设计 (2)建筑消防工程设计 消火栓系统工程设计(3)建筑排水工程设计(4)雨水排水工程设计3 建筑给水系统3.1 给水方式的选择本建筑属于高层建筑,市政给水管网水压只能满足建筑5层以下的供水需求,为了有效利用室外管网的水压,该建筑采用分区给水方式,系统竖向分为两区。低区采用由市政管网供水的直接给水方式,高区采用水泵的直接给水方式。高层建筑竖向分区给水方式有以下几种:3.1.1、并列给水方式在各分区独立设水箱和水泵,水泵集中设置在建筑底层或地下室,分别向各区供水。优点:各区是独立的给水系统,互不影响,当某区发生事故时,不影响全局,供水安全可靠;水泵集中,管理维护方便;运行动力费用低。缺点:水泵台数多,压力高,管线长,设备费用增加;分区水箱占用楼层空间,给建筑房间布置带来不便,使经济效益下降。3.1.2、串联给水方式即分区串联给水方式,水泵分散设置在各区的楼层或技术层中,低区的水箱兼作上一区的水池。优点:无高压水泵和高压管道;运行动力费用低。缺点:水泵分散设置,连同水箱所占楼层空间较大;水泵设在楼层,对防振隔音要求高,水泵分散,管理维护不方便;若下区发生事故,则其上部数区供水受影响,供水可靠性降低。3.1.3、减压水箱给水方式整个高层建筑的用水量全部由设置在底层的水泵提升至屋顶总水箱,然后再分送至各区水箱,分区水箱起减压作用。优点:水泵数量最少,设备费用低,管理维护简单;水泵房面积小,各分区减压水箱调节容积小。缺点:水泵运行动力费用高;屋顶总水箱容积大,对建筑的结构和抗震不利;建筑物高度较大、分区较多时,下区减压水箱中阀门承压过大,导致关不严或经常维修;供水可靠性差。3.1.4、减压阀给水方式工作原理与减压水箱给水方式相同,其不同之处在于以减压阀来代替减压水箱。减压阀的最大优点是占用楼层空间较小,使建筑面积发挥最大的经济效益,简化了给水系统。其缺点是水泵运行动力费用较高。饿根据提供的建筑条件,通过方案比较,采用第4种方案,即,此方案可以充分利用条件,减少投资。3.2给水系统方案的确定该建筑为高层建筑,市政给水管网工作压力为250kPa, 若只采用一个给水系统供水,建筑低层的配水点所受的静水压力很大,易产生水锤,损坏管道及附件,流速过大产生水流噪音;低层压力过大,开启水龙头时,水流喷溅严重;使用不便,根据建筑给水排水设计规范,卫生器具的最大静水压力不宜超过0.35MPa。由于其层数多,竖向高度大,为避免低层配水点静水压力过大,进行竖向分区。据设计资料以及规范中的要求并结合该楼的功能分区,将该建筑在竖向上分为2个供水区,低区为13层;高区为412层。低区利用市政给水管网供水压力直接供水;高区采用变频水泵加压供水。本设计采用高区每层均设减压阀的供水方式,采用Y型减压稳压阀。阀后压力在0.2MPa左右,使供水达到最大舒适度。变频调速水泵给水是目前高层建筑中普遍采用的一种给水方式,可以实现水泵流量供水时保持高效运行,使运行更可靠、更合理、更加节能。变频调速水泵具有以下优点:设备时刻监测供水量,使机组处于高效节能的运行状态。水泵软启动,启动电流小,能耗少。设备占地面积小,不设高位水箱,减少了建筑负荷,节省水箱占地面积,又可有效的避免水质的二次污染,给水系统也随之相应简化。水泵软启动,减少了水泵机组的机械冲击和磨损,因而延长了设备的使用寿命。管理简便、运行可靠。无负压设备可以充分利用市政管网的压力,并且不会使市政管网产生负压。无负压供水设备不需设水池,避免二次污染。前已述及,该建筑给水系统竖向分两个供水区,13为低区,利用市政管网供水压力直接供水。412层为高区。采用变频调速水泵供水。 给水管网的水力计算给水工程设计说明:进行给水管网最不利管段的水力计算,目的是算出各管段的设计秒流量,各管段的长度,计算出每个管段的当量数,进而根据水力计算表查出各管段的管径,每米管长沿程水头损失,计算管段沿程水头损失,最后算出管段水头损失之和,进而根据水头损失算出所需压力。本设计是一座十二单元式住宅楼,根据设计资料,采用给水设计方案4。建筑给水系统组成包括:引入管、水表节点、室内给水管网、给水附件、配水设施、给水设施。此十二层单元式住宅的卫生器具设置有:大便器、洗脸盆、洗涤盆、洗衣机、沐浴设备。根据设计规范,住宅区为普通住宅,最高日生活用水定额取250L/(人d),小时变化系数取=2.5,每户4人,使用时数T=24。设计秒流量当前我国使用的住宅生活给水管道设计秒流量公式是: 式中 计算管段的设计秒流量,L/s; 计算管段的卫生器具给水当量同时出水概率,%; 计算管段的卫生器具的给水当量总数;0.2 以一个卫生器具给水当量的额定流量的数值,其单位为L/s。设计秒流量是根据建筑物配置的卫生器具给水当量和管段的卫生器具给水当量同时出流概率来确定的,而卫生器具的给水当量同时出流的概率与卫生器具的给水当量数和其平均出流概率有关。根据数理统计结果得卫生器具给水当量的同时出流概率计算公式为: 式中 对于不同的卫生器具的给水当量平均出流概率的系数 卫生器具的给水当量平均出流而计算管段最大用水时概率计算公式为: 式中 生活给水管道最大用水时卫生器具的给水当量平均出流概率,%; 最高日用水定额,L/(人d); m 用水人数,人; 小时变化系数;T 用水时间。住宅区=6.25 =25042.5/(0.26.25243600)=2.3,取=2.5.根据规定,各卫生器具的给水当量如下:浴盆=1.0,淋浴器=0.75,洗脸盆=0.75,坐便=0.5,洗涤盆=1.0,洗衣机=1.0。生活给水管道的水流速度如下:DN15DN20,v0.61.0m/s;DN25DN40,v0.81.2m/s;DN50DN70,v1.5m/s;DN80及以上的管径,v1.8m/s。高区给水管网水力计算一单元高区水力计算用图见图3.1,计算结果见表3.1图 3.1 一单元高区给水水力计算用图表3.1 一单元高区给水系统水力计算表本设计住宅按“普通住宅2型”计算,U0取2.5, 取0.01512计算管段编号卫生器具名称当量总数N同时出流概率U设计秒流量qg(L/s)管径DN(mm)流速v(m/s)每米管长沿程水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)管段沿程水头损失累计(kPa)数量大便器N=0.5洗脸盆N=0.75淋浴器N=0.75洗衣机N=1.0洗涤盆N=1.0浴 盆N=1.01-21000000.51.40.14 150.750.5642.661.500 1.500 2-31000011.50.830.25 200.660.3142.140.672 2.172 3-71100012.250.680.31 250.450.1132.40.271 2.443 4-50010000.751.10.17 150.750.5641.10.620 0.620 5-61010001.250.90.23 200.610.2711.10.298 0.918 6-711100020.720.29 250.440.1083.950.427 1.345 7-92210014.250.50.42 250.640.2044.180.853 4.641 8-9000100110.20 150.990.945.284.963 4.963 9-112211015.250.450.47 250.710.2453.390.831 10.434 10-11000010110.20 150.990.947.97.426 7.726 11-322211116.250.410.52 250.790.33.71.110 19.270 12-130100000.750.90.14 150.750.5641.740.981 0.981 13-141100001.250.90.23 200.610.2710.680.184 1.165 14-2211100020.720.29 250.440.1086.880.743 1.908 15-19000100110.20 150.990.946.065.696 5.696 16-171000000.51.40.14 150.750.5640.840.474 0.474 17-181000011.50.830.25 200.660.3143.541.112 1.586 18-191100012.250.680.31 250.450.1132.350.266 1.851 19-211101013.250.570.37 250.560.1660.340.056 7.604 20-21000010110.20 150.990.945.044.738 4.738 21-221101114.250.50.42 250.640.2044.830.985 13.327 22-32221116.250.410.52 250.790.30.780.234 15.469 23-31000100110.20 150.990.998.368.276 8.276 24-250100000.751.10.17 150.750.5641.941.094 1.094 25-260100011.750.770.27 200.710.3572.70.964 2.058 26-271100012.250.680.31 250.450.1134.490.507 2.565 27-2812000130.590.35 250.530.151.10.165 2.730 28-292200013.50.550.38 250.570.171.10.187 2.917 29-302210014.250.50.42 250.640.2046.741.375 4.292 30-312210115.250.450.47 250.710.2518.222.063 6.355 31-322211116.250.410.52 250.790.35.381.614 16.245 32-3366333318.750.250.92 320.90.29430.882 51.867 33-341212666637.50.181.33 400.790.1830.540 52.407 34-351818999956.250.151.66 400.960.26330.789 53.196 35-36242412121212750.131.95 500.740.11430.342 53.538 36-3730301515151593.750.122.21 500.840.28630.858 54.396 37-38363618181818112.50.112.44 500.930.46931.407 55.803 38-39424221212121131.250.12.67 700.650.08130.243 56.046 39-404848242424241500.12.88 700.750.09330.279 56.325 40-41545427272727168.750.093.08 700.780.110.11.010 57.335 41-42545427272727168.750.093.08 700.780.1151.500 58.835 计算局部水头损失:计算管段的水头损失为:3.3.3低区给水管网水力计算一单元低区水力计算用图见图3.2,计算结果见表3.2图 3.2 一单元低区给水水力计算用图表3.2 一单元低区给水系统水力计算表本设计住宅按“普通住宅2型”计算,U0取2.5, 取0.01512计算管段编号卫生器具名称当量总数N同时出流概率U设计秒流量qg(L/s)管径DN(mm)流速v(m/s)每米管长沿程水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)管段沿程水头损失累计(kPa)数量大便器N=0.5洗脸盆N=0.75淋浴器N=0.75洗衣机N=1.0洗涤盆N=1.0浴 盆N=1.01-21000000.51.40.14150.750.5642.661.5001.5002-31000011.50.830.25200.660.3142.140.6722.1723-71100012.250.680.31250.450.1132.40.2712.4434-50010000.751.10.17150.750.5641.10.6200.6205-61010001.250.90.23200.610.2711.10.2980.9186-711100020.720.29250.440.1083.950.4271.3457-92210014.250.50.42250.640.2044.180.8534.6418-9000100110.20150.990.945.284.9634.9639-112211015.250.450.47250.710.2453.390.83110.43410-11000010110.20150.990.947.97.4267.72611-322211116.250.410.52250.790.33.71.11019.27012-130100000.750.90.14150.750.5641.740.9810.98113-141100001.250.90.23200.610.2710.680.1841.16514-2211100020.720.29250.440.1086.880.7431.90815-19000100110.20150.990.946.065.6965.69616-171000000.51.40.14150.750.5640.840.4740.47417-181000011.50.830.25200.660.3143.541.1121.58618-191100012.250.680.31250.450.1132.350.2661.85119-211101013.250.570.37250.560.1660.340.0567.60420-21000010110.20150.990.945.044.7384.73821-221101114.250.50.42250.640.2044.830.98513.32722-322211116.250.410.52250.790.30.780.23415.46923-31000100110.20150.990.998.368.2768.27624-250100000.751.10.17150.750.5641.941.0941.09425-260100011.750.770.27200.710.3572.70.9642.05826-271100012.250.680.31250.450.1134.490.5072.56527-2812000130.590.35250.530.151.10.1652.73028-292200013.50.550.38250.570.171.10.1872.91729-302210014.250.50.42250.640.2046.741.3754.29230-312210115.250.450.47250.710.2518.222.0636.35531-322211116.250.410.52250.790.35.381.61416.24532-3366333318.750.250.92320.90.29430.88251.86733-341212666637.50.181.33400.790.1830.54052.40734-351818999956.250.151.66400.960.2631.60.42152.82835-361818999956.250.151.66400.960.263143.68256.510三单元高区水力计算用图见图3.3,计算结果见表3.3图 3.3 三单元高区给水水力计算用图表3.3三单元高区给水系统水力计算表本设计住宅按“普通住宅2型”计算,U0取2.5, 取0.01512计算管段编号卫生器具名称当量总数N同时出流概率U设计秒流量qg(L/s)管径DN(mm)流速v(m/s)每米管长沿程水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)管段沿程水头损失累计(kPa)数量大便器N=0.5洗脸盆N=0.75淋浴器N=0.75洗衣机N=1.0洗涤盆N=1.0浴 盆N=1.01-20100000.751.10.17 150.750.56410.564 0.564 2-31100001.250.90.23 200.610.27410.274 0.838 3-41100012.250.680.31 250.450.11310.113 0.951 4-511100130.590.35 250.530.150.70.105 1.056 5-62110013.50.550.38 250.570.171.880.320 1.376 6-82210014.250.50.42 250.640.2046.221.269 2.644 7-8000100110.20 150.990.944.764.474 4.474 8-102211015.250.450.47 250.710.2453.760.921 8.040 9-10000010110.20 150.990.948.387.877 7.877 10-322211116.250.410.52 250.790.35.991.797 17.714 11-120100000.751.10.17 150.750.56410.564 0.564 12-130100011.750.770.27 200.710.3572.881.028 1.592 13-151100012.250.680.31 250.450.1131.420.160 1.753 14-15000010110.20 250.440.1083.940.426 0.426 15-211100113.250.570.37 250.560.1665.060.840 3.019 16-171000000.51.40.14 150.750.5640.70.395 0.395 17-181010001.250.90.23 200.610.2741.680.460 0.855 18-2011100020.720.29 250.440.1083.50.378 1.233 19-20000100110.20 150.990.944.924.625 4.625 20-2111110030.590.35 150.990.941.411.325 7.184 21-322211116.250.410.52 250.640.2042.590.528 10.731 22-230100000.751.10.17 150.790.310.300 0.300 23-241100001.250.90.23 150.990.9910.990 1.290 24-251100012.251.10.50 150.750.56410.564 1.854 25-2611100130.590.35 250.530.150.70.105 1.959 26-272110013.50.550.38 250.570.171.880.320 2.279 27-292210014.250.50.42 250.640.2046.221.269 3.547 28-29000100110.20 150.990.944.854.559 4.559 29-312211015.250.450.47 250.710.2453.390.831 8.937 30-31000010110.20 150.990.948.387.877 7.877 31-322211116.250.410.52 250.790.31.920.576 17.390 32-3366333318.750.250.92 320.90.29430.882 46.716 33-341212666637.50.181.33 400.790.1830.540 47.256 34-351818999956.250.151.66 400.960.26330.789 48.045 35-36242412121212750.131.95 500.740.11430.342 48.387 36-3730301515151593.750.122.21 500.840.28630.858 49.245 37-38363618181818112.50.112.44 500.930.46931.407 50.652 38-39424221212121131.250.12.67 700.650.08130.243 50.895 39-404848242424241500.12.88 700.750.09330.279 51.174 40-41545427272727168.750.093.08 700.780.110.11.010 52.184 41-42545427272727168.750.093.08 700.780.1151.500 53.684 三单元低区水力计算用图见图3.2,计算结果见表3.2表3.3三单元低区给水系统水力计算表本设计住宅按“普通住宅2型”计算,U0取2.5, 取0.01512计算管段编号卫生器具名称当量总数N同时出流概率U设计秒流量qg(L/s)管径DN(mm)流速v(m/s)每米管长沿程水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)管段沿程水头损失累计(kPa)数量大便器N=0.5洗脸盆N=0.75淋浴器N=0.75洗衣机N=1.0洗涤盆N=1.0浴 盆N=1.01-20100000.751.10.17 150.750.56410.564 0.564 2-31100001.250.90.23 200.610.27410.274 0.838 3-41100012.250.680.31 250.450.11310.113 0.951 4-511100130.590.35 250.530.150.70.105 1.056 5-62110013.50.550.38 250.570.171.880.320 1.376 6-82210014.250.50.42 250.640.2046.221.269 2.644 7-8000100110.20 150.990.944.764.474 4.474 8-102211015.250.450.47 250.710.2453.760.921 8.040 9-10000010110.20 150.990.948.387.877 7.877 10-322211116.250.410.52 250.790.35.991.797 17.714 11-120100000.751.10.17 150.750.56410.564 0.564 12-130100011.750.770.27 200.710.3572.881.028 1.592 13-151100012.250.680.31 250.450.1131.420.160 1.753 14-15000010110.20 250.440.1083.940.426 0.426 15-211100113.250.570.37 250.560.1665.060.840 3.019 16-171000000.51.40.14 150.750.5640.70.395 0.395 17-181010001.250.90.23 200.610.2741.680.460 0.855 18-2011100020.720.29 250.440.1083.50.378 1.233 19-20000100110.20 150.990.944.924.625 4.625 20-2111110030.590.35 150.990.941.411.325 7.184 21-322211116.250.410.52 250.640.2042.590.528 10.731 22-230100000.751.10.17 150.790.310.300 0.300 23-241100001.250.90.23 150.990.9910.990 1.290 24-251100012.251.10.50 150.750.56410.564 1.854 25-2611100130.590.35 250.530.150.70.105 1.959 26-272110013.50.550.38 250.570.171.880.320 2.279 27-292210014.250.50.42 250.640.2046.221.269 3.547 28-2900010
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 图纸设计 > 任务书类


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!