资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,Page,*,Severn Trent Services,美国水环纯,STS,水务集团,CSD(Beijing)Water Works Operation Management Co.,Ltd,中持(北京)水务运营有限公司,Tetra Denite,反硝化深床滤池,1,Severn Trent Services美国水环纯STS,反硝化深床滤池,提标改造的利器,反硝化深床滤池,Tetra/Denite,一池多用,具有脱氮、除磷、去除悬浮物等多种功能,N0,3,-N 1.0 mg/L,(,TN 3.0 mg/L,),TP 0.3 mg/L,SS 5 mg/L,浊度,2 NTU,每去除,1mg/l N0,3,-N,甲醇耗量,3 mg/l,灵活转换运行模式,,STS/Tetra,滤池被,废水工程 处理及回用,引用经典案例,,中文版,P695,.,2,反硝化深床滤池提标改造的利器反硝化深床滤池Tetra/De,反硝化深床滤池,提标改造的利器,3,反硝化深床滤池提标改造的利器3,项目,Item,COD,cr,BOD,5,SS,TN,NH,4,-N,TP,备注,Infl.,进水水质,60,20,40,25,5,(,8,),2,Effl.,出水水质,50,10,10,15,5,(,8,),0.5,反硝化深床滤池的工艺流程,4,项目 ItemCODcrBOD5SSTNNH4-NTP备注I,5,世界反硝化深床滤池的发明者及领导者,5世界反硝化深床滤池的发明者及领导者,反硝化深床滤池结构,6,反硝化深床滤池结构 6,滤 料,高比重滤料 最小2.6,高等级硅砂,6 X 9,目,直径范围,2.0 3.0 mm,均匀系数小于 1.35,球形度 0.80,莫氏硬度 6-7,最小为 6.0,7,滤 料 高比,8,304SS,布气主管,气水分布系统,304SS,布气支管,T Block,滤砖,布水廊道盖板,8,8304SS布气主管气水分布系统304SS布气支管T Blo,气水分布系统,9,气水分布系统9,10,气水分布系统,10 气水分布系统,窄长型的廊道结构,,使滤池进水更为均匀,滤池进水,11,窄长型的廊道结构,滤池进水,滤池进水,12,滤池进水 12,气水反冲洗,特殊的滤砖结构,,使滤池,反洗,(,气洗和水洗,),效果良好,13,气水反冲洗 特殊的滤砖结构,使滤池,驱除氮气,反硝化过程中产生氮气,使得过滤产生气阻,通过驱除氮气,确保滤池运行效果,14,驱除氮气 反硝化过程中产生,滤池的工作过程,正常进水,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,项目,单位,进水水质,出水水质,TN,mg/L,20,15,TP,mg/L,2,0.5,SS,mg/L,20,10,PAC,、甲醇、乙酸、乙酸钠,15,滤池的工作过程正常进水2.空气反洗3.气水反洗4.单,滤池的工作过程,正常进水,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,反硝化作用,16,滤池的工作过程正常进水2.空气反洗3.气水反洗4.单,滤池的工作过程,正常进水,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,反硝化作用,17,滤池的工作过程正常进水2.空气反洗3.气水反洗4.单,滤池的工作过程,反洗,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,18,滤池的工作过程反洗2.空气反洗3.气水反洗4.单独水,滤池的工作过程,反洗,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,19,滤池的工作过程反洗2.空气反洗3.气水反洗4.单独水,滤池的工作过程,反洗,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,20,滤池的工作过程反洗2.空气反洗3.气水反洗4.单独水,滤池的工作过程,反洗,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,21,滤池的工作过程反洗2.空气反洗3.气水反洗4.单独水,滤池的工作过程,水 洗,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,22,滤池的工作过程水 洗2.空气反洗3.气水反洗4.单独,滤池的工作过程,驱氮,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,23,滤池的工作过程驱氮2.空气反洗3.气水反洗4.单独水,滤池的工作过程,正常进水,2.,空气反洗,3.,气水反洗,4.,单独水洗,1.,正常进水,5.,驱除氮气,24,滤池的工作过程正常进水2.空气反洗3.气水反洗4.单,项目,Item,COD,cr,BOD,5,SS,TN,NH,4,-N,TP,备注,Infl.,进水水质,60,20,40,25,5,(,8,),2,Effl.,出水水质,50,10,10,15,5,(,8,),0.5,滤池的工艺流程,25,项目 ItemCODcrBOD5SSTNNH4-NTP备注I,Denite,Filters,反硝化滤池,FE,Controller,(MMI),控制器,Nitrate,Analyzer,硝酸盐分析仪,Influent,Sampler,进水取样器,Effluent,Sampler,出水取样器,Effluent,出水,Influent,进水,Flow Meter,流量计,Methanol,Feed Pump,加药泵,Denite,反硝化深床滤池碳源控制流程图,26,DeniteFEControllerNitrateInfl,Scituate,MA,2.4 MGD,Water Temperature 6-7Celsius,水温,6-7,摄氏度,冬季低温的应用,27,Scituate,MA 冬季低温的应用 27,Scituate,MA,2.4 MGD,Water Temperature 6-7Celsius,水温,6-7,摄氏度,冬季低温的应用,28,Scituate,MA 冬季低温的应用 28,反硝化滤池的运行成本,当污水,BOD5/TN,35,时,认为反硝化碳源充足。当废水中缺少有机物质时,为了给反硝化反应提供足够的电子供体,需要外加碳源。以甲醇、乙醇、乙酸、乙酸钠、葡萄糖为例,比较碳源投加量及费用。各种碳源反硝化化学计量关系式:,5CH,3,OH+6NO,3,-,3N,2,+5CO,2,+7H,2,O+6OH,-,5C2H,5,OH+12NO,3,-,6N,2,+10CO,2,+9H,2,O+12OH,-,5CH,3,COOH+8NO,3,-,4N,2,+10CO,2,+6H,2,O+8OH,-,5CH,3,COONa+8NO,3,-,4N,2,+10CO,2,+6H,2,O+8ONa,-,5C,6,H,12,O,6,+24NO,3,-,12N,2,+30CO,2,+18H,2,O+24OH,-,29,反硝化滤池的运行成本 当污水BOD5/TN3,常用碳源投加量及投加费用一览表,碳源,理论投加量(碳源,g/TNg,),实际投加量 (碳源,g/TNg,),单价 (元,/kg,),吨水消耗(,g/m,),吨水折合成本(元),若仅冬季投加吨水折合成本(元),甲醇,1.9,2.9,3.1,14.5,0.045,0.011,乙醇,1.37,乙酸,2.68,4.5,3.3,22.5,0.074,0.018,乙酸钠,3.66,5.0,2.6,25.0,0.065,0.016,葡萄糖,2.68,注:上表按总氮去除为,5mg/L,计算。,反硝化滤池的运行成本,30,常用碳源投加量及投加费用一览表碳源理论投加量(碳源g/TN,常用碳源比较一览表,中文名:,甲醇,乙酸,乙酸钠,外文名:,methyl alcohol,acetic acid,sodium acetate,别名:,木酒精,醋酸,醋酸钠,结构简式:,CH3OH,CH3COOH,C2H3NaO2,相对分子质量:,32.04,60.05,82.03,化学品类别:,有机物,-,醇,有机物,-,酸,有机物,-,管制类型:,不管制,不管制,不管制,储存:,密封保存,密封保存,密封保存,熔点,(),:,-97.8,16.6,324,沸点,(),:,64.8,117.9,相对密度:,0.79,1.0492,1.528,闪点,(),:,11,39,爆炸上限,%(V/V),:,44,17,爆炸下限,%(V/V),:,5.5,4,溶解性:,溶于水,可混溶于醇、醚等多数有机溶剂。,易溶于水和乙醇,其水溶液呈弱酸性,溶于水和乙醚,微溶于乙醇。,反硝化滤池的运行成本,31,常用碳源比较一览表中文名:甲醇乙酸乙酸钠外文名:methyl,反硝化深床滤池运行费用一览表,吨水消耗,消耗品单价,吨水费用,备注,一、电费,0.047348KWh,0.7,元,/KWh,0.033,元,/m,二、药剂,1,、,PAC,0.004113kg/m,2.5,元,/kg,0.010,元,/m,2,、碳源,0.015kg/m,2.6,元,/kg,0.065,元,/m,以乙酸钠计,全年投加,三、费用合计,0.108,元,/m,全年投加碳源,0.016,0.059,元,/m,仅冬季投加碳源,注:上表按总氮去除为,5mg/L,,总磷为,0.5mg/L,计算。,反硝化滤池的运行成本,32,反硝化深床滤池运行费用一览表吨水消耗消耗品单价吨水费用备注一,10 Ft Deep Clear Well,3,米深的清水池清澈见底,出水效果,33,10 Ft Deep Clear Well,出水效果,34,出水效果 34,Turbidity of the Effluent,滤池出水浊度,出水效果,35,Turbidity of the Effluent滤池出水,美国,Tampa,地区,78,年开始采用,STS/Tetra,反硝化滤池,(38,万吨,/d),经,10,年时间,Tampa,海湾生态得到恢复,典型案例,36,美国Tampa地区78年开始采用STS/Tetra反硝化滤池,Tampa,海湾,37,Tampa海湾37,38,38,1,、河北廊坊香河县三强污水厂,(中持环保公司设计、施工),(一级,B,提标至一级,A,标准,,2,万吨,/,天),2,、山西潞城污水处理再生水利用工程,(太原市政院设计),(,5-5-3-1,的标准,即,BOD5mg/l;SS5mg/l;TN3mg/l;TP1mg/l.,),3,、浙江嘉善,污水处理厂,(一级,A,,西北市政院设计),4,、无锡芦村污水处理厂四期,(一级,A,,华北市政院设计,,5,万吨,/,天),5,、无锡惠山污水处理厂三期,(一级,A,,无锡市政院设计,,2.5,万吨,/,天),6,、济宁金乡污水处理厂,(一级,A,,济南市政院设计,,3,万吨,/,天),7,、天津张贵庄污水处理厂一期工程,(一级,A,,天津市政院,,20,万吨,/,天),8,、天津泰达,-,威立雅污水处理厂(,一级,A,,天津市政院设计,,10,万吨,/,天),国内应用业绩,39,1、河北廊坊香河县三强污水厂(中持环保公司设计、施工),河北香河县三强污水厂,设计规模:,2,万吨,/,
展开阅读全文