第二章 气相色谱分析

上传人:沈*** 文档编号:247334153 上传时间:2024-10-18 格式:PPT 页数:98 大小:2.50MB
返回 下载 相关 举报
第二章 气相色谱分析_第1页
第1页 / 共98页
第二章 气相色谱分析_第2页
第2页 / 共98页
第二章 气相色谱分析_第3页
第3页 / 共98页
点击查看更多>>
资源描述
单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,第二章 气相色谱分析,为什么用气相色谱,If you can do it by GC,You should do it by GC.,-,H.M.McNair,如果你能用气相色谱完成,你就应该用气相色谱完成。,气相色谱可分析的有机物占目前发现总有机物的,15,20,。,应用范围:挥发温度,500,热稳定性好,相对分子量,400,气相色谱系统,检测器,进样器,色谱柱,GAS,气源,柱温箱,数据处理,2-1,气相色谱法概述,色谱法,(chromatography),:以试样,组分在固定相和流动相间的,溶解、吸附、分配、离子交换或其他亲和作用的差异,为依据,而建立起来的各种,分离分析方法,称色谱法。,色谱柱:,进行色谱分离用的细长管。,固定相:,(,stationary phase,),管内保持固,定、起分离作用的填充物。,流动相:,(,mobile phase,),流经固定相的空隙,或表面的,冲洗剂,。,按固定相的几何形式分类:,1.,柱色谱法,,2.,纸色谱法,,3.,薄层色谱法,。,按两相所处的状态分类,:,气相色谱法,液相色谱法,气,-,固,色谱法,液,-,固,色谱法,气,-,液,色谱法,液,-,液,色谱法,色谱过程示意图,待分离组分 ,和,载气,A,B,C,D,气相色谱仪通常由五部分组成:,载气系统:气源、气体净化器、供气控,制阀门和仪表。,进样系统:进样器、汽化室。,分离系统:色谱柱、控温柱箱。,检测系统:检测器、检测室。,记录系统:放大器、记录仪、,色谱工作站。,图,1,、色谱过程 图,2,、色谱图,A,B,K,A,K,B,色谱图,(,chromatogram,),:,试样中各组分经色谱柱分离后,按先后次序经过检测器时,检测器就将流动相中,各组分浓度变化转变为相应的电信号,,,由记录仪所记录下的,信号,时间曲线,或,信号,流动相体积曲线,,称为,色谱流出曲线,.,色谱图界面,色谱流出曲线及有关术语,相关术语:,基线:,在操作条件下,仅有,纯流动相,进,入检测器时的流出曲线。,峰高与峰面积:,色谱峰顶点与峰底之间的,垂直距离称为峰高,(peak height),。,用,h,表示。,峰与峰底之间的面积称为峰面积,(peak area),,,用,A,表示。,峰的区域宽度:,a,、峰底宽,W,D,=4=1.70 W,h/2,b,、半高峰宽,W,h/2,=2.355,c,、标准偏差,峰宽,W,0.607h,=2,保留值,:,1),保留时间,:,从,进样至被测组分出现浓度最大值,时所需时间,t,R,。,2),保留体积:从,进样至被测组分出现最大浓度,时,流动相通,过的体积,,V,R,。,死时间:,不被固定相滞留的组分,从进样至出现浓度最大值时所需的时间称为死时间,(dead time),,,t,M,。,死体积,:,不被固定相滞留的组分,,从,进样至出现浓度最大值时流动相通,过的体积称为死体积,(dead volume),,,V,M,。,(,F,0,为柱尾载气体积流量),V,M,=,t,M,F,0,调整保留值,:,1),调整,保留时间:扣除死时间后的保留时间。,t,R,=t,R,t,M,2,),调整,保留体积:扣除死体积后的保留体积。,V,R,=V,R,V,M,或,V,R,=t,R,F,0,相对保留值(,relative retention,),在相同的操作条件下,待测组分与参比组分的调整保留值之比,用,r,i,,,s,表示,色谱分析的实验依据:,、根据色谱峰的位置(保留时间)可以进行定性分析。,2,、根据色谱峰的面积或峰高可以进行定量分析。,3,、根据色谱峰的展宽程度,可以对某物质在实验条件下的分离特性进行评价。,由此可知:相对保留值应该与柱长、柱径、填充情况、流动相流速等条件无关,而仅与温度、固定相种类有关。当,r,i,,,s,=1,时两个组分不能分离。,思考题:请简述气相色谱仪的主要构成部分有哪些?,组分在固定相中的浓度,组分在流动相中的浓度,2-2,气相色谱分析理论基础,一、分配平衡的几个参数:,1,、分配系数,组分一定时,,K,主要取决于固定相性质,组分及固定相一定时,温度增加,K,减小,试样中的各组分具有不同的,K,值是分离的基础,选择适宜的固定相可改善分离效果,影响,K,的因素,固定相,温度,2,分配比,(,容量因子,),k,组分在固定相中的质量,组分在流动相中的质量,c,s,、,c,m,分别为组分在固定相和流动相的浓度,(g/ml),;,V,m,为色谱柱中流动相的体积,近似等于死体积,,V,s,为色谱柱中固定相的体积,3,、分配系数,和分配比之间的关系,分配系数,K,与柱中固定相和流动相的体积无关,而取决于组分及两相的性质,并随柱温、柱压变化而变化。,容量因子,k,决定于组分及固定相的热力学性质,随柱温、柱压的变化而变化,还与流动相及固定相的体积有关。,K,与,k,都是与组分及固定相的热力学性质有关的常数。,K,与,k,都是衡量色谱柱对组分保留能力的参数,数值越大,该组分的保留时间越长。,k,可直接从色谱图上获得。,理论上可以推导出:,Phase ratio(,相比,,b,):,V,M,/V,S,反映各种色谱柱柱型及其结构特征,填充柱(,Packing column,),:635,毛细管柱(,Capillary column,),:501500,色谱柱类型,柱长(米),内径(毫米),.5-10,2-4,5-100,.530,5-100,.1-.25,填充柱,530,系列柱,细孔径柱,填充柱,开管柱(毛细管柱),壁涂,开管柱,GCTECH 2-05,Analytical Training Center,二、色谱分离的基本理论,1,、塔板理论(,Martin and Synge 1941,),塔板理论认为,一根柱子可以分为,n,段,在每段内组分在两相间很快达到平衡,把每一段称为一块理论塔板。设柱长为,L,,,理论塔板高度为,H,,,则,H=,L/n,式中,n,为理论塔板数。,理论塔板数(,n,)可根据色谱图上所测得的保留时间(,t,R,),和峰底宽(,w,),或半峰宽(,w,h/2,),按下式,推算,:,或,1,塔板理论柱分离效能指标,*k,=1,塔板号,载气塔板体积数,0,1,2,3,4,柱出口,0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,1,0.5,0.25,0.125,0.063,0.032,0.016,0.008,0.004,0.002,0.001,0,0,0,0,0,0,0,0.5,0.5,0.375,0.25,0.157,0.095,0.056,0.032,0.018,0.010,0.005,0.002,0.001,0,0,0,0,0,0.25,0.375,0.375,0.313,0.235,0.165,0.111,0.072,0.045,0.028,0.016,0.010,0.005,0.002,0.001,0.,0,0,0.125,0.25,0.313,0.313,0.274,0.22,0.166,0.094,0.070,0.049,0.033,0.022,0.014,0.008,0,0,0,0,0.063,0.157,0.235,0.274,0.274,0.247,0.207,0.151,0.110,0.08,0.057,0.040,0.027,0,0,0,0,0,0.032,0.079,0.118,0.138,0.138,0.124,0.104,0.076,0.056,0.040,0.028,0.020,理论塔板数,理,论,塔,板,高,度,色谱柱长度,柱效能指标,当色谱柱长度一定时,塔板数,n,越大,(,塔板高度,H,越小,),,被测组分在柱内被分配的次数越多,柱效能越高,所得色谱峰越窄。,不同物质在同一色谱柱上的分配系数不同,用有效塔板数和有效塔板高度作为衡量柱效能的指标时,应指明测定物质。,有效塔板数,有效板高,通常,用有效塔板数(,n,eff,),来评价柱的效能比较符合实际。,n,eff,越大或,H,eff,越小,则色谱柱的柱效越高。,n,=,1+k,k,2,n,eff,2,速率理论影响柱效的因素,速率理论认为,(,J.J.Van,Deemter,1956),,,单个组分粒子,在色谱柱内固定相和流动相间要发生,千万次转移,,加上分子扩散和运动途径等因素,它在柱内的运动是高度不规则的,是,随机的,,在柱中随流动相前进的速度是不均一的。,流动相,线速度,范弟姆特方程,A,项为,涡流扩散项,;,B/u,项,为分子扩散项,;,Cu,为,传质项,,,u,为载气线速度,单位为,cm/s,。,1),涡流扩散项,A,固定相颗粒越小,填充的越均匀,A,越小,,H,越小,柱效越高,色谱峰越窄。,2),分子扩散项,B,/,u,(,纵向扩散项,),流动相,柱内谱带构型,相应的响应信号,产生原因:,浓度梯度,影响因素:,流动相流速;,气体扩散系数,3),传质阻力项,Cu,气相传质阻力,固定相颗粒越小,载气分子量越小,气相传质阻力越小,液相传质阻力,固定液粘度及液膜厚度越小,液相传质阻力越小,4),流动相线速度对板高的影响,2-3,色谱分离条件的选择,一、分离度(,resolution,),相邻两色谱峰保留值之差与两组分色谱峰底宽度平均值之比,用,R,表示。,分离度可以用来作为衡量色谱峰分离效能的指标。,R,越大,表明两组分分离效果越好,保留值之差取决于固定液的热力学性质,色谱峰宽窄反映色谱过程动力学因素,及柱效能高低,对于峰形对称且满足正态分布的色谱峰:,R=1,分离程度为,98%,;,R=1.5,,分离程度可达,99.7%,。,所以,R=1.5,时可认为色谱峰已完全分开。,二、色谱分离关系式,设两相邻峰的峰宽相等,即,w,1,=w,2,,,则,又知,另,称为柱效项;,称为柱选择项;,容量因子项。,相对保留因子,与柱效的关系(柱效因子),与容量因子的关系,R n,1/2,增加柱长,减小塔板高度,限制:,L,过长,保留时间延长,分析时间延长,色谱峰扩展。,使用性能优良的色谱柱,并选择最佳分离条件,k,值增大,有利于分离,但,k,10,时,对,R,的增加不明显,也会显著增加分析时间,k,的最佳范围:,1 10,与柱选择性的关系,分离度、柱效、柱选择性的关系,r,2,1,越大,柱选择性越好,分离效果越好。如果两个相邻峰的选择因子足够大,则即使色谱柱的理论塔板数较小,也可以实现分离。,L=,16R,2,H,有效,a,a,-1,2,=n,有效,H,有效,例题:,设有一对物质,其,r,2,1,=,=1.15,要求在,H,eff,=0.1cm,的某填充柱上得到完全分离,试计算至少需要多长的色谱柱?,解:要实现完全分离,,R1.5,故所需有效理论塔板数为:,使用普通色谱柱,有效塔板高度为,0.1cm,故所需柱长应为:,分离度与,k,、,n,及,的关系,k,从,1,增加到,3,,,R,增加到原来的,1.5,倍,(,k,:2-7),n,增加到原来的,3,倍,,,R,增加到原来的,1.7,倍,从,1.01,增加到,1.1,,,增加约,9,,,R,增,加到原来的,9,倍,结论,选择合适的固定相,(,流动相,),以增加,是改善分离度最有效的方法,1),各组分的分配系数必须不同。这一条件通过选择合适的固定相来实现。,2),区域扩宽的速度应小于区域分离的速度,即色谱柱的柱效要高。,3),在保证快速分离的前提条件下,色谱柱应足够长。,使试样中的不同组分分离需要满足的条件,例,1,:,有一根,l m,长的柱子,分离组分,1,和,2,得到如下色谱图。图中横坐标,l,为,记录笔走纸距离。若欲得到,R=1.2,的分离度,有效塔板数应为多少?色谱柱要加到多长?,解法,1,R,=1.2,1),2),解法,2,1),同解法,1,2),三、色谱条件的选择,1,、载气流速的选择(与分析时间、柱效有关),实际工作中,为了缩短分析时
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 管理文书 > 施工组织


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!