资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,25,8732 电磁流量计,Managing The Process Better.,MEASUREMENT,Technical,FARADAYS 原理,E=kBDV,导电过程介质,衬里,线圈,感应电极,不锈钢管,法兰,磁场,“,B,”,(恒定强度),“,E,”,“,E,”,流量(英尺每秒),“,D,”,D,“,V,”,Faraday,s Law,感应电极,线圈,密封电极腔,8705 Flowtube,8705 流量管设计,Installation,变送器位置,电极,流量,Installation,流量管安装,流量管安装,这些设备造成,不精确,从出口处,2 倍管道内径,Installation,需限制的设备,从入口处,5倍管道内径,缩管,Installation,外壳旋转,导电及无内涂层管道,不导电,或,有涂层管道,Installation,接地,LOCAL OPERATOR INTERFACE,在这个部分您会学习怎样用本地操作界面来组态 8732C.,完成此部分后, 您将能够 :,1.描述LOI按键的功能.,2. 用LOI对8732E进行组态.,LOI,上,下,退回/输入,选择,LOI,本地操作界面,本地操作菜单,459.00 GAL/MIN,66.42 % SPAN,Display Set,Basic Set,LOI,本地操作菜单,Display Setup(显示设置),Basic Setup(基本设置),Detailed Setup(细节设置),XMTR Test(变送器测试),XMTR Trim(变送器修正),Device Info(设备信息),Display Set,Basic Set,LOI,DISPLAYSETUP(显示设置),BASIC SETUP(基本设置),DETAILED SETUP(细节设置),TRANSMITTER TEST(变送器测试),TRANSMITTER TRIM(变送器修正),DEVICE INFO(设备信息),LOI 菜单树,Lock (锁定显示),Flow rate Display(流量显示),Totalize Display(总量显示),Units(单位),Tube size(管径),Tube Cal No.(标定系数),URV, LRV(上限, 下限),Damping(阻尼),Xmtr Test(变送器测试),Loop Test(回路测试),Pulse Test(脉冲测试),4-20 Trim(4-20修正),Auto Zero(自动调零),Gain Trim(增益修正),Lo Flow C/O(小流量切除),Dig O/P Conf(数字组态),Special Units(特殊单位),Coil Freq(线圈频率),Signal Processing(信号处理),LOI,单位,特殊单位:,1.体积单位,2. 基本体积单位,3. 转换系数,4. 时间单位,5. 流量单位,例:,体积单位 = Barl (Barrels),基本体积单位 = Gallons*,转换系数 = 31,(31Gal = 1 Barrel),时间单位 = Hour*,流量单位 = Bph,*可选,Units,Tube Size,Units: Ft/Sec,Max 30.00 fps,LOI,管径,0.15,0.30,0.5,1,1.5,2,3,4,6,8,10,12,Units,Tube Size,Tube Size: 4in,Max 4507L/M,LOI,流量管标定系数,Display Set,Basic Set,Tube Cal No:,0920406609166011,Tube Size,Tube Cal No.,LOI,标定系数解析,流量管标定系数,10028,0,52,10003,001,6 Hz时的流量管增益.,流量管类型,0,= 8711 or 8701 6,1,= 8714A 模拟器,2,= 8701 4,3,= 抗干扰,4-9,= 未用,在驱动频率下的流量管零点偏移,30Hz时的流量管增益,.,标定系统,000,= 流量管与8712A一起标定,001,= 8701 流量管与8712C一起标定,011,= 8711 流量管与8712C一起标定,Cal Number Breakdown,模拟输出,必须先设置管径!,Tube Cal No.,URV,LRV,URV Configure,LRV Configure,Upper Range,20ma= 227800L/M,LOI,数字输出选择,数字输出选择,Dig Out Select,Pulse Output,Dig Out Select,Select: Pulse Out,LOI,脉冲输出定标,8732 最大频率限制= 1000 Hz,例:,给定流量为200 gal/min (3.33 gal/sec),一个脉冲= 0.01 gal, 决定变送器输出的频率 :.,频率 =,最大流量(gal/sec),脉冲定标(gal/pulse),频率=,3.33 gal/sec,0.01 gal/pulse,= 333 pulses/sec,1 Pulse =,0.0250 L,Pulse Scaling,Pulse Width,LOI,显示控制,流量 - % 量程,495.0 GAL/MIN,66.42% SPAN,流量 - 总量,495.0 GAL/MIN,0.00 GAL,% 量程 - 总量,66.42% SPAN,0.00 GAL,LOI,总量,设置显示,Display Set,Basic Set,正向 - 反向,FWD: 0.00 GAL,REV: 0.00 GAL,纯 - 毛重,NET: 0.00 GAL,GROSS: 0.00 GAL,LOI,不精确,不精确因素,变送器组态,管径,标定系数,6 Hz - 30 Hz,自动调零,流量管方向,湿气,电极覆盖,-,通常产生干扰,需限制的设备,(,缩管、扩管、阀门,.),Inaccuracy,分体时中间电缆的接线图,存放安装注意事项小结,存放,流量计两端夹持衬里的两块木板不能提前拆除,一定要等到安装时再拆下,以防衬里变形,流量计需要拆下存放一段时间时应该用木板夹持住流量计两端,安装,保证液体满管,保证接地良好,特别注意不要受现场电器设备干扰,上下游直管段至少保证前,5D,后,2D,流向与表体标注的一致,注意垫片材质及内径,法兰螺栓必须用扭矩扳手按顺序上紧,Inaccuracy,
展开阅读全文