Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,*,*,Gas Chromatography,Mobile phase:,Inert gas such as N2 or He.,Stationary phase:,May be,solid(GSC)or,Non volatile liquid at operating temperature over inert support(GLC).,Mixture:,Mixture,components,must be:,1,-,Volatile:Volatile material usually have molecular weight not exceed 400 500 Dalton.,2,-,Thermo stable.,Instruments:,1-Gas Tank.,2-Flow meter.,3-Injector system for sample application.,4-Column and oven.,5-Detector.,6-Amplifier and Recorder.,stationary phase:,GSC:,1-Silica gel.,2-Charcoal(Activated).,3-Molecular sieves(synthetic inorganic materials).,GLC:,Liquid or low melting solid coating an inert support.,e.g.of supports:,1,-,Chromosorb.,2,-,Celite.,3,-,Glass beeds,.,4,-,Teflon,e.g.of liquids or low-melting solids:,Each liquid have a,maximum operating Temperature.,Silicon gum rubber(higher than 250 C).,Paraffin oil(250 C).,Polyethylene glycol(up to 250 C).,Column:,1-Packed Columns:,2-6 mm id and 1-3 meters in length.,2-Capillary Column:,0.2 0.5 mm id and 10-100 meters in length.Some columns may reach up to 300 meters.,Types of capillary columns:,1-,Wall Coated Open tubular(WCOT):,Used in GLC,the stationary liquid coats the column wall.,2-Support Coated Open tubular(SCOT):,The inert support is fused to the column wall by special machine then the stationary liquid coat the support.It is used in GLC.,3-Porous layer Open tubular(PLOT):,The stationary solid is bonded to the wall of the column.,Not commercially produced.,4-Micro-Packed Columns:,The columns are coiled and packed with the desired support with stationary liquid or solid stationary phase under pressure and vibrations.,Capillary Columns give mush better resolution but their sample capacity is much lower than the packed columns(about 1/10 or less).,Operating Temperature:,Operating Temperature can be looked at as the polarity of mobile phase in case of adsorption chromatography.,Very low temp:Tailing of peaks.,Very high temp:No separation of peaks.,Temperature programming:,Allows starting the process at low temperature and gradually increasing the temperature till reach the maximum required temperature.,Column bleeding:,Elution of the liquid stationary phase itself if very high temperature is used(exceed maximum operating temperature).,Conditioning of Columns:,Means heating the column before use at a temperature 25-50 0C above the normal working temperature.However,that must not exceed the maximum operating temperature.The mobile phase is allowed to flow during the conditioning but the column outlet must be disconnected from the detector.Conditioning aims to clean the column from any impurities.,Detectors:,They are used to indicate the presence and measure the amount of the components in the column effluent.,Examples of the commonly used detectors are:,1,-,Thermal Conductivity Detector(TCD).,2,-,Flame Ionization Detector(FID).,3,-,Electron Capture Detector(ECD).,Sample Introduction,Sample introduction will affect the separation,accuracy and precision of the results.The method of sample application will depends mainly on the nature of the sample.,Gaseous samples:,They are introduced using special valves.,Liquid Samples:,Include liquids,liquids or solids in suitable solvents.They are introduced by injection via septum seal.,Capillary column have low capacity so we have to apply very small amount of samples.This can be achieved by:,1-Dilution of sample with solvent:,This will lead to problem due to large amount of solvents that may affect separation and quantitation.,2-Injection of very small amount of more concentrated solution:,That leads to increase the error in measurements.,3-Using modified injectors that allow splitting of samples:,Only part of the injected sample go to the column and the rest of the sample go to vent.The split ratio to give good results is usually 1:100.,Head Space Sampling:,The sample is contained in sealed vial and maintained at constant temperature for about 20 min.so equilibrium will be achieved between gas and liquid states.The vapour phase is then allowed to enter the column.,Derivatization of non volatile samples:,Non volatile samples containing acidic hydrogen can be converted into more volatile more thermally stable derivatives as:,1-Silylation:,This is the most widely used method.Alkylsilyl group will replace the acidic hydrogen.,pyridine,R-OH,+,Cl-SiMe,3,R-O-SiMe,3,+,HCl,(TMS),Trimethylchlorosilane,2-Acylation:,COCF,3,R-OH+O R-O-COCF,3,COCF,3,(TFAA),Trifluoroaceticanhydride,3-Alkylation:,RCOOH+BF,3,/MeOH RCOOMe,Boron trifluoride,Peak symmetry:,Good system must result in a symmetric peaks with narrow base.Asymmetry ratio(As)can be calculated:,b,As=-,a,Where a and b should by measured at10%height of the peak.,As for good peak will be 0.9-1.1.,The peak shape also can be predicted by calculation of the Tailing factor(T):,W,T=-,2F,Where W and F must be measured at 5%height of the peak.,Ideal peak wi
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 商业管理 > 商业计划


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!