资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,*,Model STT350/STT35F,高性能,高精度、,4-20mA,DE,或 现场总线,Fieldbus,Model STT250,直接安装式的智能型变送器,4-20mA,HART,或,DE,协议,Model STT170,可编程、低成本,4-20mA,HART,或,现场总线,Foundation Fieldbus,温度传感器和套管,RTD&T/C,传感器和套管,具有,FM,CSA,和,ATEX,认证,温度变送器,温度变送器,高性能,传感器开路检测,T/C,冗余,硬件写保护,温差测量,通讯方式,:4-20 mA,DE,协议 和,现场总线,FOUNDATION Fieldbus,STT350,智能温度变送器,温度变送器,STT350,现场总线温度变送器,包含以前型号的所有性能,可接受各种工业标准温度信号,:,热电阻,热电偶,毫伏电压或欧姆等,.,1,或,2,个传感器,可选择冗余和温差,第一批注册可以软件下载的设备,第一批注册带有链路活动调动器的设备,第一批注册带有,PID,的变送器,温度变送器,STT350,智能温度变送器,ModelSTT35FSTT350,Protocol:FieldbusDig.DE/4-20mA,Configuration Tools:NI ConfiguratorSCT,SFC,Emerson 375MC Toolkit,Pt100 Accuracy0.01%0.01%,T/C Type J Accuracy0.04%0.04%,CJ Accuracy0.25,0,C0.25C,Advanced FeaturesDifferential TempDifferential Temp,Redundant T/C Redundant T/C,Housing SizeField,mount,Field,mount,Integral MetersFieldbus Digital meter Smart meter,通用输入,可双路输入,结构紧凑,可一体化安装,各种外壳形式及材料,可满足广泛的用途,具有一体化现场表头,可选,4-20mA,DE,或,HART,通讯方式,具有良好的性能,/,价格比,温度变送器,STT250,智能温度变送器,温度变送器,STT250,智能温度变送器,STT25M,4 to 20 mA,输出,STT25D,4 to 20 mA,输出 或,Honeywell Digital DE,通讯协议,STT25H,4 to 20 mA,输出 或,or HART,通讯协议,STT25T,双路输入,TC/TC,RTD/RTD.,Duplex RTD or TC sensors used with Auto Sensor Cross Checking to track and alarm if sensors drift.,双,RTD,或热电阻,具有传感器短路检测和飘移跟踪报警,另外一种故障的情况,温度变送器运行一定时间后,:,保护管内有金属屑、灰尘、接线柱间脏污,热电阻丝材料受腐蚀变质会使指示值比实际值低或示值不稳,此种情况不会引起温度变送器发出能引起切换的关键故障。,为此温度变送器中加入了更加保证安全的温差报警功能,温度差值,(PV1-PV2),一旦某一路的温度发生变化,,使,2,路温度产生温差并达到了预先组态好的温差值,,变送器就会发出报警信号。,温度变送器,STT250T,智能双输入温度变送器,壁式安装,2,寸短管安装,导轨安装,温度变送器,STT250,智能温度变送器,温度变送器,STT250,智能温度变送器,SIL 2/3,认证,温度变送器,STT250,智能温度变送器,SIL 2/3,认证,温度变送器,STT250,智能温度变送器,ModelSTT25HSTT25MSTT25D,Protocol:HART 5,4-20mA 4-20mADig.DE,4-20mA,Configuration Tools:MC Toolkit SCT,SFC,SCT,SFC,Emerson 275/375 MC ToolkitMC Toolkit,TPS TDC,TPS,Inputs:,Pt100 Accuracy0.025%0.025%0.025%,T/C Type J Accuracy0.04%0.04%0.04%,CJ Accuracy0.5,0,C0.5,0,C 0.5,0,C,Advanced Features:Failsafe Latching,Failsafe Latching Failsafe Latching,Fault detectionFault detectionFault detection,Housing SizeHead mountHead mount Head mount,Exp.ProofExp.ProofExp.Proof,温度变送器,STT250,智能温度变送器,STT25S&STT25T,ModelSTT25SSTT25T,Protocol:HART 6HART 5,Configuration Tools:MC Toolkit MC Toolkit,Emerson 375 Emerson 275/375,Inputs:,Pt100 Accuracy0.025%0.025%,T/C Type J Accuracy0.04%0.04%,CJ Accuracy0.5,0,C0.5,0,C,Advanced Features:TUV SIL2/3Redundant,Tag lineMultiple sensors,Housing SizeHead mount Head mount,Exp.ProofExp.Proof,Integral MetersEU meter EU meter,模拟量通讯,HART,协议通讯,FF,现场总线通讯,STT171,STT173,STT17H,STT17F,RTD,输入,STT17C,组态,Analog 4-20mA,输出,错误信息:,NAMUR NE43,RTD+T/C,输入,STT17C,组态,Analog 4-20mA,输出,错误信息,NAMUR NE43,输入,/,输出间带光电隔离,RTD+T/C,输入,STT17C or HART,组态,HART/4-20mA,输出,HART Multi-drop capable,错误信息,NAMUR NE43,输入,/,输出间带光电隔离,RTD+T/C,输入,FOUNDATION fieldbus protocol,现场总线,Function blocks:2 analogue,1 PID,FISCO certified,认证,Basic or LAS capability,输入,/,输出间带光电隔离,温度变送器,STT170,温度变送器系列概况,温度变送器,STT170,温度变送器,STT171,STT173 and STT17H,订购以上型号时,可以在工厂预组态,或用,STT17C,组态工具及,MCT,组态工具组态。,组态参数:,Tag number,位号,Sensor type,传感器类型,URV,LRV,量程上、下限,Response time,响应时间,Output Limits,输出极限,Sensor error action,传感器失效动作,STT17F,组态此型号时,需要通过,Fieldbus DCS,或,Rosemount 375,通讯器。,温度变送器,STT170,温度变送器,ModelSTT171STT173STT17H STT17F,Protocol:4-20mA 4-20mAHART 5 Fieldbus,Configuration Tools:STT17CSTT17CSTT17C Emerson375,MC Toolkit,Inputs:RTD 2&3 wire2,3&4 wire2,3&4 wire2,3&4 wire,TC/mVTC/mVTC/mV,Pt100 Accuracy0.1%0.1%0.1%0.1%,T/C Type J Accuracy0.1%0.1%0.1%0.1%,Galvanic Isolation:NoYesYesYes,Approvals:FM,CSA,FM,CSA,FM,CSA,FM,CSA,ATEXATEX ATEXATEX,Integral MetersEU MeterEU MeterEU Meter,温度变送器,防雷保护,通常在,15,到,600,微秒到达峰值,800,伏,在,40,到,3000,微秒后衰减到峰值的一半,装置现场比较典型的浪涌电压,霍尼韦尔温度变送器的防雷保护有,2,种结构形式,原理和功能相同,1.,内置式,2.,外置式,本安型,本安型,坚固型(防震型),ATEX Zone 1,FM Class I,Div 1,ATEX Zone 2,FM Class I,Div 2,Complete exclusion of access:,防尘和防水,温度变送器,多用途通讯器,温度变送器,多用途通讯器,对任何,Honeywell DE,设备组态,:,包括,ST3000,变送器和,STT3000,温度变送器,.,对任何,HART,设备组态,:,包括所有公布了的,HART DD,文件的 设备,而不限于其生产厂家。,可以很容易地通过,PC,机连接,支持下载供货商的新的,DD,文件。,可以通过用户界面上的导航键,很容易地对设备进行组态。,提供三种形式,可以满足环境要求:,坚固型(防震型),-,恶劣环境但没有防爆要求。,Zone 2 approvals:,本安认证,包括,with FM Class I,Div 2 and ATEX Zone 2 approvals.,Zone 1 approvals:,本安认证,包括,FM Class I,Div 1 and ATEX Zone 1 approvals.,完全支持所有,HART 5.X,指令 和,HART 6.X,通用指令,以及利用,DD-IDE/SDC 625,技术的所有“开放”的技术标准。,谢 谢,温度变送器,
展开阅读全文