髌骨骨折(英文版)课件

上传人:风*** 文档编号:242419151 上传时间:2024-08-23 格式:PPT 页数:31 大小:5.14MB
返回 下载 相关 举报
髌骨骨折(英文版)课件_第1页
第1页 / 共31页
髌骨骨折(英文版)课件_第2页
第2页 / 共31页
髌骨骨折(英文版)课件_第3页
第3页 / 共31页
点击查看更多>>
资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,髌骨骨折(英文版) PPT,髌骨骨折(英文版) PPT,1,It is important to fully evaluate patella fractures on the AP x-ray as well as,the lateral x-ray. The AP x-ray demonstrates the number of fragments and,vertical splits in the sagittal plane that are not visible on the lateral x-ray.,It is important to fully evalu,2,It is important to fully evaluate patella fractures on the AP x-ray as well as,the lateral x-ray. The AP x-ray demonstrates the number of fragments and,vertical splits in the sagittal plane that are not visible on the lateral x-ray.,It is important to fully evalu,3,Lateral radiograph demonstrating complete separation of,the patella with loss of extensor mechanism.,Lateral radiograph demonstrati,4,A vertical midline incision is performed over the patella.,A vertical midline incision is,5,After coming through subcutaneous tissue, the patella fracture is immediately evident. The clot and cancellous,bone edges are cleaned.,After coming through subcutane,6,大家学习辛苦了,还是要坚持,继续保持安静,大家学习辛苦了,还是要坚持继续保持安静,7,A lamina spreader demonstrates the fracture site.,A lamina spreader demonstrates,8,The articular surface of the patella and trochlear groove are,evident upon flexion of the knee.,PATELLA ARTICULAR,SURFACE,TROCHLEAR,GROOVE,PROXIMAL,DISTAL,The articular surface of the p,9,RETINACULAR TEAR,With displaced patella fractures there are concomitant,retinacular tears medially and laterally.,RETINACULAR TEARWith displaced,10,TROCHLEA,PATELLA ARTICULAR,SURFACE,After complete debridement and cleaning of the fractures, a,cannulated screw guidewire can be placed retrograde through,the fracture site, close and parallel to the articular surface.,TROCHLEAPATELLA ARTICULARAfter,11,The drill is then used also in a retrograde fashion.,The drill is then used also in,12,The saggital plane split is seen when the distal fragment is flexed.,This fracture is fixed with a transverse lag screw that will not interfere with the cannulated screws.,The saggital plane split is se,13,Using a clamp, the fracture is reduced.,Using a clamp, the fracture is,14,Using a clamp, the fracture is reduced.,FRACTURE,REDUCTION,Using a clamp, the fracture is,15,A second clamp is necessary in this,case to maintain the reduction.,A second clamp is necessary in,16,Closeup of the complete reduction,using several clamps.,Closeup of the complete reduct,17,After the reduction is complete, the K-wires are visualized in the,lateral and AP planes, which are used to evaluate not only the,guidewire placement but also the reduction.,After the reduction is complet,18,Lateral and AP views. Notice that the lag screw is placed,between the inferior lateral and inferior central fragment,but does not extend into the fragment on the medial side, as,this would interfere with the placement of the K-wire.,Lateral and AP views. Notice,19,The two cannulated screws are placed over the guidewires. These,screws must be large enough to enable the tension band to be placed,through them.,The two cannulated screws are,20,Each manufacturer is different; the surgeon must be confident that,the cannulation of the screw will accommodate the cable or wire system.,Each manufacturer is different,21,The screw should be placed such that it is short of the end of the,bone. This is to avoid the cable or wire system from being injured,by the sharp threaded end of the screw.,The screw should be placed suc,22,The cable system is introduced through one screw looped around,anteriorly, then placed in the same direction through the second,screw.,The cable system is introduced,23,The two ends are pulled through a connector and underneath,the clamp, which remains in place during the tightening.,The two ends are pulled throug,24,In this case the Dahl-Miles system is used and the tightener,is connected to the two free ends after a fastener is attached.,In this case the Dahl-Miles sy,25,Lateral X-Ray,Lateral X-Ray,26,AP x-ray demonstrating the tightening,of the cable grip system.,AP x-ray demonstrating the tig,27,After the wire is sufficiently tightened and crimped,in place, it is trimmed very close to the sleeve.,After the wire is sufficiently,28,The retinaculum is then carefully repaired on both the,medial and lateral sides to afford stability and additional,support to the reconstruction.,The retinaculum is then carefu,29,Closeup of the final reconstruction.,Closeup of the final reconstru,30,Lateral radiograph demonstrating the reduction. Notice that the,screw tips are shy of the cartilage on the patella. The cable grip,system wraps around the bone and is not making a sharp angle,at the tip of the screw.,Lateral radiograph demonstrati,31,
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 办公文档 > PPT模板库


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!