发电机系统6512--Generator-systems课件

上传人:无*** 文档编号:241966943 上传时间:2024-08-08 格式:PPT 页数:39 大小:9.81MB
返回 下载 相关 举报
发电机系统6512--Generator-systems课件_第1页
第1页 / 共39页
发电机系统6512--Generator-systems课件_第2页
第2页 / 共39页
发电机系统6512--Generator-systems课件_第3页
第3页 / 共39页
点击查看更多>>
资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,ET8612,单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,*,Generator systems,Service Training,Approval:PNO,Generator design,Generator systems,Rotor and stator,Rotor,U1,U2,V1,V2,W1,W2,Stator,Generator design,3 phase asynchronous induction generator,ABB,Generator design,Standard generator,3 phase asynchronous induction generator-VRCC,ABB,Generator design,VRCC,3 phase asynchronous induction generator-VCS,Generator design,VCS,Generator systems,Generator systems,Vestas generator systems,Opti tip/Fast Active Stall,VCS(Opti speed),V90/3.0 MW,V80-2.0 MW,V90-3.0 MW,V39/500 kW,V82-1.65 MW,V47-660 KW,V66-1.65 MW,V80-1.8 MW,1-2%slip,Stator,Rotor,400-690 V,50 HZ,1-10%slip=1650 RPM.,IGBT,690V,50/60 HZ,Capacitor battery,Stator,Rotor,690/1000 V,50 HZ,AC from grid(400/480 V),50 Hz,10%of total power,900 to 1900 RPM,VCS DC =800/700 V,dc,dc,ac,dc,ac,dc,Stator,Rotor,480 V,60 Hz,1000 to 1800 RPM,dc,dc,1000 V,60 HZ,ac,dc,ac,dc,Stator,Rotor,Rectifier,1758 rpm=stator 3.08 MW,RCC/VRCC(Opti slip),VCRS(Opti speed),Generator systems,Phase compensation,Generator systems,Phase compensation,Phase compensation,R,XL,C,U,I,C,U,I,XL,U,R,I,Phase compensation,Phase compensation,XL,The generator consists of several coils,Capacitors must be added to the system to correct the power factor.,Function,Phase compensation,U,I,L1,L2,L3,1,2,3,4,ON,ON,ON,ON,Generator,ON,Capacitor test,Phase compensation,11.16:Capacitor test Current,No.1.2.3.4.-L1-51 A,IN OUT OUT OUT -L2-50 A,Sec.0 0 0 0 -L2-52 A,The capacitors can be tested by using the test menu 11.16,Troubleshooting,Phase compensation,Safety,Phase compensation,Thyristors,Generator systems,Thyristors,Thyristors are used for reducing the current when connecting and disconnecting,Thyristors,Cut-in,WEIER,L1,L2,L3,Main Contacter,RPM,Power,1500,2000,1000,500,0,600,700,500,400,300,200,100,KW,Thyristor 1,Thyristor 2,Thyristor 3,Thyristors,3,2,1,G1,0,L3,L2,L1,Troubleshooting,Thyristors,11.17:Thyristor 0:Gen1 1:Gen2,-L1-25 A,Generator state:,Connecting,-L2-23 A,Thyristor angle:45,-L2-24 A,The thyristors can be tested by using the test menu 11.16,Generator systems,VRCC,VRCC=Vestas Rotor Current Control,VRCC V80 1.8 MW,VRCC V47 660 kW,VRCC,What is VRCC,480 V,IGBT driver,CT309,Control unit,L1,L2,L3,12,10,8,6,4,2,0,20,18,16,14,12,10,8,6,4,2,0,22,20,18,16,0,%,KW,Power,Slip,RPMx100,Generator,Wind Speed,m/s,Pitch angle,Degrees,25,5,15,20,10,-5,90,45,DATA,On,Off,IGBT,IGBT,R732,R725A-C,K700A,K700B,K700C,Generator 1,VRCC function V80/1.8 MW(60 Hz),VRCC,Generator systems,VCS,VCS=Vestas Converter System,VCS,What is VCS,Frequency converter function,VCS,AC,AC,DC,+,-,480 V 50 Hz,+400 V,-400 V,CT297,R560,K537,K536 A,K536C,K502,K501,L552,L551,K500,Rotor Inverter,Grid Inverter,480 V,690 V,EMC Filter,10,12,14,16,18,20,RPM,8,Generator,690,700,680,710,670,Grid,Voltage,Stator,Voltage,710,700,680,690,670,DC Link,Power,800,600,400,200,100,16,14,12,10,4,6,8,18,KW x 100,V,20,Current flow,Converter,+,-,0,Data,VCP,C620,C562,OVP,CT297,R560,K537,K536 A,K536C,K501,L552,L551,K500,Rotor Inverter,Grid Inverter,480 V,690 V,10,12,14,16,18,20,RPM,8,Generator,690,700,680,710,670,Grid,Voltage,Stator,Voltage,710,700,680,690,670,DC Link,Power,800,600,400,200,100,16,14,12,10,4,6,8,18,KW x 100,V,20,Current flow,Converter,+,-,0,Data,VCP,C620,OVP,EMC Filter,C562,DC Link,Generator systems,Troubleshooting,Troubleshooting,4 P,50 HZ,690 V AC,Generator,U1,U2,V1,V2,W1,W2,Troubleshooting,Stator,Troubleshooting,U1,U2,V1,V2,W1,W2,L1,L3,L2,Delta connection,Stator,U1,U2,V1,V2,W1,W2,L1,L3,L2,Star connection,Troubleshooting,Rotor,Troubleshooting,Standard rotor,Rotor,Troubleshooting,VRCC/VCS Rotor,Sliprings,Rotor,VRCC/VCS,U1,U2,V1,V2,W1,W2,Motor tester,Megger,Troubleshooting stator,VRCC/VCS Rotor,Slip rings,Motor tester,Megger,Troubleshooting rotor,Troubleshooting,VRCC/VCS,Winding with shorted coil,Winding grounded at edge of slot,Winding shorted phase to phase,Troubleshooting,Generator windings,写在最后,成功的基础在于好的学习习惯,The foundation of success lies in good habits,38,谢谢大家,荣幸这一路,与你同行,ItS An Honor To Walk With You All The Way,讲师:,XXXXXX,XX,年,XX,月,XX,日,
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 管理文书 > 施工组织


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!