资源描述
单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,*,*,通钢集团,单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,*,*,通钢集团,降低变电所照明电耗,双环圈,动力厂动力作业区,发表人:李丽娟,王祥东,圈 名,双环圈,主题编号,W566-001,完成主题,1件,圈 长,李怀富,辅导员,王 君,发 表 人,李丽娟,王祥东,圈 员,李怀富 李丽娟 李 雷 王祥东 石洪艳 吴 慧,刘晓慧 刘景光 刘旭超 李 刚 管 帅 范海艳,组 圈,时 间,2008320,活动时间,2008.3.202008.10.25,圈会时间,4次/月,1、活动圈成员组成,一、活动圈简介,1、主题选取评估,评估因素,主题,能力,数据,量化,效果,创意,总得分,降低供电线路功率损耗,38,20,22,42,36,158,降低变电所照明电耗,50,45,40,48,28,211,合理摆放备品备件,提 高 工 作 效率,43,20,18,37,32,150,备注:采用因素评分法:优-5分,良-4分,中-3分,可-2分,差-1分,由以上评估得分可知:本次活动主题为:,降低变电所照明电耗,二、主题选取,2、主题选取理由:,灯具布局不合理,照明时间过长 夜间长明灯,老型号灯具光照度差 能耗高,二、主题选取,3、活动方案书,月、周,项目,三月,四月,五月,六月,七月,工作分担,2,3,1,2,3,4,1,2,3,4,1,2,3,4,1,2,3,4,P,1、成立活动圈,李怀富,2、主题选定,李怀富,3、暂时登记,李丽娟,4、现状分析,王祥东,5、目标设定,刘晓慧,6、正式登记,李丽娟,D,7、拟定对策,刘晓慧,C,8、对策实施,王祥东,A,9、效果确认,王祥东,10、对策标准化,石洪艳,11、撰写成果报告书,李丽娟,12、成果发表,李丽娟,备注:1.方案用虚线代表“.实际用实线代表“2每月按四周进行方案,二、主题选取,主控室,仓库,水房,直流室,走廊,休息室,走廊,6.3KV高压室,室外场地,A、照明平面图老所,三、现状分析,主控室,仓库,水房,直流室,走廊,休息室,走廊,6.3KV高压室,室外场地,备注:图中 为夜间长明白炽灯;为不用状态;为夜间长明日光灯;为不用状态,1、变电所照明简介,由图可知:.3KV高压室 走廊 直流室 主控室 室外场地照明为夜间长明状态,B、照明平面图新所一楼,走廊,6.3KV高压室,仓库,水房,变压器室,变压器室,2#,1#,电容器室,电容器室,电容器室,仓库,更衣室,学习室,三、现状分析,备注:图中 为间断照明白炽灯;为夜间长明白炽灯;为不用状态;为夜间长明日光灯;为不用状态,由图可知:.3KV高压室 走廊 水房 更衣室照明为夜间长明状态 1#2#主变和电容器室为间断照明状态,主控室,走廊,66KV高压室,三、现状分析,2#,变压器室,1#,变压器室,备注:图中 为间断照明白炽灯;为夜间长明白炽灯;为夜间长明日光灯;,C、照明平面图新所二楼,由图可知:走廊 主控室为夜间长明状态 66KV高压室为间断照明状态,2、鱼骨图分析,降,低,变,电,所,照,明,电,耗,人为,设备,环境,方法,长明灯,老型号灯能耗高,灯具布局不合理,未制定开关灯制度,管理,责任心不强,老型号灯光照度差,灯具选型,光照度过大,开关灯不准时,无节电意识,监管力度不够,照明过度,季节变换,夏季开灯时间短,冬季开灯时间长,照明度差异大,照明时间长,三、现状分析,项目,地点,种类,数量,(只),功率,(W/只),总功率,(W),状态,(夜间),负责人,2008.04.16,主控室,日光灯,20,40,800,常亮,王祥东,2008.04.16,楼道及走廊,白炽灯,2,100,200,常亮,王祥东,2008.04.16,水房 更衣室,日光灯,4,40,160,常亮,王祥东,2008.04.16,6.3KV高压室,日光灯,14,40,560,常亮,王祥东,2008.04.16,(1.2.3)#电容室,白炽灯,16,25,400,间断,王祥东,2008.04.16,(1.2.3)#电容室,白炽灯,12,25,300,不用,王祥东,2008.04.16,(1.2)#变压器室,白炽灯,12,25,300,间断,王祥东,2008.04.16,(1.2)#变压器室,白炽灯,18,25,450,不用,王祥东,2008.04.16,66KV高压室,白炽灯,32,25,800,间断,王祥东,2008.04.16,仓库 学习室,日光灯,4,40,160,不用,王祥东,2008.04.16,6.3KV墙壁灯,白炽灯,14,25,350,不用,王祥东,2008.04.16,库房,日光灯,4,40,160,不用,王祥东,合 计,152,4640,收集时间,1、数据收集,新所照明状况统计表,四、要因验证,1、数据收集,老所照明状况统计表,项目,地点,种类,数量,(只),功率,(W/只),总功率,(W),状态,(夜间),负责人,2008.04.16,66KV开关场地,探照灯,2,450,900,常亮,李丽娟,2008.04.16,6.3KV高压室,白炽灯,5,200,1000,常亮,李丽娟,2008.04.16,走廊,白炽灯,1,100,100,常亮,李丽娟,2008.04.16,直流配电室,白炽灯,1,200,200,常亮,李丽娟,2008.04.16,主控室,日光灯,6,40,240,常亮,李丽娟,2008.04.16,主控室墙壁灯,白炽灯,6,25,150,不用,李丽娟,2008.04.16,水房,白炽灯,1,100,100,不用,李丽娟,2008.04.16,6.3KV墙壁灯,白炽灯,12,25,300,不用,李丽娟,2008.04.16,库房,日光灯,1,40,40,不用,李丽娟,合 计,35,3030,收集时间,四、要因验证,日期,间断照明时间(h),间断照明总功率(KW),间断照明用电量(KW.h),长明灯照明时间(h),长明灯总功率(KW),长明灯用电量(KW.h),日用电量(KW.h),1,0.833,1.5,1.2495,10.97,4.16,45.6352,46.8847,2,0.833,1.5,1.2495,10.94,4.16,45.5104,46.7599,3,0.833,1.5,1.2495,10.89,4.16,45.3024,46.5519,4,0.833,1.5,1.2495,10.84,4.16,45.0944,46.3439,5,0.833,1.5,1.2495,10.79,4.16,44.8864,46.1359,6,0.75,1.5,1.125,10.71,4.16,44.5536,45.6786,7,0.833,1.5,1.2495,10.7,4.16,44.512,45.7615,8,0.833,1.5,1.2495,10.56,4.16,43.9296,45.1791,9,0.833,1.5,1.2495,10.53,4.16,43.8048,45.0543,10,0.833,1.5,1.2495,10.5,4.16,43.68,44.9295,11,0.833,1.5,1.2495,10.43,4.16,43.3888,44.6383,12,0.833,1.5,1.2495,10.79,4.16,44.8864,46.1359,13,0.833,1.5,1.2495,10.31,4.16,42.8896,44.1391,14,0.833,1.5,1.2495,10.43,4.16,43.3888,44.6383,15,0.833,1.5,1.2495,10.39,4.16,43.2224,44.4719,1、数据收集,四月份照明用电量统计表,四、要因验证,日期,间断照明时间(h),间断照明总功率(KW),间断照明用电量(KW.h),长明灯照明时间(h),长明灯总功率(KW),长明灯用电量(KW.h),日用电量(KW.h),16,0.833,1.5,1.2495,10.3,4.16,42.848,44.0975,17,0.833,1.5,1.2495,10.09,4.16,41.9744,43.2239,18,0.833,1.5,1.2495,10.14,4.16,42.1824,43.4319,19,0.833,1.5,1.2495,9.66,4.16,40.1856,41.4351,20,0.75,1.5,1.2495,10.04,4.16,41.7664,43.0159,21,0.75,1.5,1.125,10.4,4.16,43.264,44.389,22,0.75,1.5,1.125,9.96,4.16,41.4336,42.5586,23,0.75,1.5,1.125,9.9,4.16,41.184,42.309,24,0.75,1.5,1.125,10.37,4.16,43.1392,44.2642,25,0.75,1.5,1.125,10.41,4.16,43.3056,44.4306,26,0.75,1.5,1.125,9.9,4.16,41.184,42.309,27,0.75,1.5,1.125,9.88,4.16,41.1008,42.2258,28,0.75,1.5,1.125,9.91,4.16,41.2256,42.3506,29,0.75,1.5,1.125,9.84,4.16,40.9344,42.0594,30,0.75,1.5,1.125,9.75,4.16,40.56,41.685,合计,1327,1、数据收集,四月份照明用电量统计表,四、要因验证,日期,间断照明时间(h),间断照明总功率(KW),间断照明用电量(KW.h),长明灯照明时间(h),长明灯总功率(KW),长明灯用电量(KW.h),日用电量(KW.h),1,0.75,1.5,1.125,9.74,4.16,40.5184,41.6434,2,0.75,1.5,1.125,9.56,4.16,39.7696,40.8946,3,0.75,1.5,1.125,9.48,4.16,39.4368,40.5618,4,0.75,1.5,1.125,9.49,4.16,39.4784,40.6034,5,0.75,1.5,1.125,9.49,4.16,39.4784,40.6034,6,0.75,1.5,1.125,9.46,4.16,39.3536,40.4786,7,0.75,1.5,1.125,9.38,4.16,39.0208,40.1458,8,0.75,1.5,1.125,9.42,4.16,39.1872,40.3122,9,0.75,1.5,1.125,9.38,4.16,39.0208,40.1458,10,0.75,1.5,1.125,9.35,4.16,38.896,40.021,11,0.75,1.5,1.125,9.3,4.16,38.688,39.813,12,0.75,1.5,1.125,9.23,4.16,38.3968,39.5218,13,0.75,1.5,1.125,9.21,4.16,38.3136,39.4386,14,0.75,1.5,1.125,9.15,4.16,38.064,39.189,15,0.75,1.5,1.125,9.11,4.16,37.8976,39.0226,16,0.75,1.5,1.125,9.15,4.16,38.064,39.189,1、数据收集,五月份照明用电量统计表,四、要因验证,日期00,间断照明时间(h),间断照明总功率(KW),间断照明用电量(KW.h),长明灯照明时间(h),长明灯总功率(KW),长明灯用电量(KW.h),日用电量(KW.h),17,0.75,1.5,1.125,9.14,4.16,38.0224,39.1474,18,0.75,1.5,1.125,9.03,4.16,3
展开阅读全文