贝朗血透机维修手册自检

上传人:pia****nwu 文档编号:240730374 上传时间:2024-05-03 格式:PPT 页数:57 大小:4.44MB
返回 下载 相关 举报
贝朗血透机维修手册自检_第1页
第1页 / 共57页
贝朗血透机维修手册自检_第2页
第2页 / 共57页
贝朗血透机维修手册自检_第3页
第3页 / 共57页
点击查看更多>>
资源描述
1Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024Service Manual-Chapter 3维修手册第三章维修手册第三章 2Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024常规常规通常每次开机后进入治疗前都必须进行自检。所有关系到安全的功能都将被测试,确保治疗安全进行。治疗开始前不可跳过自检。仅在自检程序完全通过后开始治疗程序才是安全可靠的。3Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024安全第一安全第一 -自检程序步骤自检程序步骤1.开机后开机后软件和定标数据检查软件和定标数据检查 上次消毒记录检查上次消毒记录检查2.治疗前自检治疗前自检safety system安全报警系统安全报警系统internal hydraulic进水进水 blood leak漏血传感器漏血传感器 Heater加热器加热器Temperature温度传感器温度传感器Conductivity电导度传感器电导度传感器Ultrafiltration超滤部分超滤部分SAD空气传感器空气传感器pressure sensors血路压力血路压力4.消毒冲洗消毒冲洗消毒:温度、浓度达到要求消毒:温度、浓度达到要求+冲洗冲洗okpriming冲洗机器3.治疗 同时传感器不间断的监测并由独立的监测系统处理器计算报警临界值自动或 手动开机 4Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024开机初始化开机初始化开机信号发送到SMPSLLC初始化硬件装载程序装载定标数据LLS初始化硬件装载程序装载定标数据启动 Diabus通讯检查检测板开关K1位置 0-2-3启动与开关位置相应的程序 Therapy-TSM-Software Update报警信息:RAM/ROM Error 或 CRC calibration Error 如果自检失败 TLC主板BIOS程序启动从硬盘启动程序 5Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024治疗之前治疗之前冲洗水路 填充水箱,冲洗整个水路 6Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024自检自检所有测试步骤都由控制板控制完成监测板通过自己的传感器监测整个过程。监测板测试 D24V 和 B24V 电压继电器各 3 秒。打开 24V 继电器,给控制板进行下一步测试提供电压。任一自检步骤如失败将自动循环监测该步骤。维修界面有自检程序代码,显示自检程序进度。7Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024自检自检 维修界面维修界面 chapter 3 page 36-38自检代码 8Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024自检自检 自检代码总览自检代码总览Code Test Code00 xxxNo tests or rinsing 16xxx Sound and LED test(from SW 7.51)17xxxLLC DFS Test 18(analog voltage test from SW 7.51 and sup.version 3)11xxxBlood leak detector12xxxDFS leakage test15xxx HDF online 完整性测试(only for Dialog HDF online)20 xxx UF pump21xxx Conductivity22xxxTemperature TSD30 xxx SAD:level test31xxx SAD:counter test32xxx Pressure sensors blood side:equality test for blood side pressure sensors33xxx Pressure sensors blood side:blood side pressure test34xxx Substitution pump HDF bag(only for Dialog HDF bag)35xxx Flow detector HDF bag(only for Dialog HDF bag)36xxx Load cell HDF bag(only for Dialog HDF bag)37xxx Disinfection valve VD40 xxx Leakage test substitution line S online HDF online 9Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024自检状态自检状态 chapter 3 page 36 10Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024自检自检 显示状态显示状态 11Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024Sound and LED Test 报警声光测试报警声光测试可能测试到的配件:-LED/OSD Board defective-扬声器-触发器(主板或FPB板)-连线导电不良或接头松动-SMPS的维修跳线P101短路-SMPS 的继电器 VGB 或 VGDLLS 通过电流进行测试,两个OSD(Optical Status Display)板上的红色 LED灯 发光 同时 扬声器发出报警声(software version 7.5x)。Code LLC 1610 x-1699x/SUP 16001-16028 12Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024 检测检测+/-12 V 避免电压过高或过低避免电压过高或过低控制板控制板 水路水路12V电压测试电压测试Code LLC 1710 x 1799x/SUP 17001-12036 仅适用于使用仅适用于使用3型检测板并型检测板并 的机器的机器 13Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024漏血测试:1.测试 绿光“信号2.测试 红光“信号 3.比较红绿信号自动定标:自动定标,补偿漂移 LED电路开关和 红绿光信号放大电路 okokLED 发光管 red/green接收管 LED额外的接收管LED,提供自动定标参数透析液漏血传感器漏血传感器 2型型Code LLC 1102x-1199x/SUP 11000-11012 14Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024DFS 透析液通路压力测试DFS 测试程序中,以下部件将被测试是否漏气:平衡腔包括所有阀门和平衡腔膜片冲洗桥整体:-漏血传感器-VDE,VDA-消毒阀门和透析器接头空气分离室,UF pump自FPE 到 RVDA的所有软管,接头,管夹等。对于HDF Online机器:可测试出是否破裂或接口漏气。Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 15Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024备注简化图例只显示两个腔体中的一个平衡腔体正压由 FPE正压泵提供,压力的测量和监测由PDA压力传感器负责要漏气测试成功必须首先冲洗整个水路并保持水路无空气可能的故障:1)UF pump超滤泵漏气或故障2)任何微小泻漏,水路不通可尝试动作:增加RVFPE高压保护阀的压力至1.5 bar 可能通过DFS 测试Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 16Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024RVFPEDDEVLAVLARVFPARVFPABLVDMDialog+DFS 透析液通路漏气测试透析液通路漏气测试 阀门关闭阀门打开为简化图例,没有显示出如下与DFS压力测试关系不密切的部件:-空气分离室-冲洗桥-消毒阀-漏血传感器-RVFPA,DDE 17Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024RVFPEDialog+DFS 透析液通路漏气测试透析液通路漏气测试 阀门关闭阀门打开 18Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024Pressure build-up at VDABKCode LLC 1220 x/SUP 12002 预计PDA 425 mmHgPDA压力达不到预计值则可能:FPE/RVFPE故障,,VDABK1/2漏气,膜片漏气RVFPE?s 16000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 19Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024UF pump testCode LLC 1225x/SUP 12002-12016 RVFPE 16000 s此时LLS 必需检测到超滤泵转动5圈否则可能是超滤泵传感器故障或超滤泵卡死Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 20Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024压力不能降低则可能:超滤泵故障或RVDA阀门需调整,排水管打折或 VDEBK1/2 漏气Pressure decrease at VDABK by UFPCode LLC 1230 x/SUP 12021 PDA 425 mmHg 16000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 阀门关闭阀门打开 24Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024 Pressure decrease by UFPCode LLC 1250 x/SUP 12101 PDA 380 mmHg380mmHg如果PDA压力60秒内不能如预计减低到380mmHg以下则可能 VDEBK1 或 VDEBK2漏气超滤泵故障 16000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 25Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024Diaphragm testCode LLC 1255x/SUP 12101-12148 如压力升高则可能:一个或两个膜片漏气如压力过低则可能:VABK1 或 VABK2 漏气PDA 425 mmHg 16000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 阀门关闭阀门打开 27Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024液体按膜片移动的方向进入平衡腔Code LLC 1265x/SUP 12151 32000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 28Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024利用UFP超滤泵降低 VABK阀门处的压力Code LLC 1270 x/SUP 12151PDA 380 mmHg 32000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 29Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024VEBK testCode LLC 1275x/SUP 12151-121881,3bar1,3bar300-340 mmHg若 PDA压力过高则说明:VEBK1 或 VEBK2 漏气若PDA压力过低则说明:VABK1 或 VABK2 漏气 32000 sPDA 300-450 mmHgDialog+DFS 透析液通路漏气测试透析液通路漏气测试 30Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024完成完成DFS测试测试压力释放Code LLC 1280 x/SUP 12000打开所有阀门并控制泵使PDA 压力调节在-200和+200 mmHg之间 32000 sDialog+DFS 透析液通路漏气测试透析液通路漏气测试 31Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024HDF Online DialogDF FilterDF FilterHDF FilterHDF FilterFPEFPEFPAFPAUFUFHFBHFBVDEVDEVDAVDAVBPVBPVSAAVSAAVSAEVSAEVDFFVDFFVLAVLAVSBVSBDDEDDERVDARVDARVFPERVFPERVFPARVFPAVBEVBEPDABL对于HDF Online机器,DFS压力测试后,还有一些部件是可能漏气的:如超净滤器,或阀门 VBE、VSAE、VSAA等所以还有HDF Online 测试VDMDialog+DFS 透析液通路漏气测试透析液通路漏气测试 32Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024平衡腔概要可能故障:DFS-测试失败软管/管路连接处漏气阀门漏气(需逐个判断)膜片漏气水路内空气过多初始化错误 报警提示“膜移动”(membrane movement)膜位移传感器板或线圈故障(应总是对称运动)FPE/FPA老化,或故障某个阀门不能打开软管打折,水路堵塞水路内空气过多Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 33Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024检查破片时需使用维修程序 TSM,1,3 barRVDAUF1,3 barFBK10,4 bar打开阀门 VEBK1,VEBK2,VABK1,VABK2关闭阀门 VDEBK1,VDEBK2,VDABK1,VDABK2取下连接到过滤网 FBK1 并用三通连接注射器和压力表和过滤网(如图所示)用注射器向管路内加压力至,然后用夹子夹住注射器侧软管如果任一膜片破裂漏气则压力快速降低(需同时更换两块膜片)平衡腔膜片(如何判断膜片破裂漏气)Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 34Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024检查外部漏气进水路的方法,进入维修程序 TSM,关闭阀门 VVB 和 VBICP取下连接过滤网 FBK1 的软管并通过三通连接注射器和压力表(如图所示)用注射器向 DF透析液模块(水槽)方向打水加压,观察哪里漏水出来。FBK1Manometer1,3 bar平衡腔(由于漏气而大量气泡进入水路时)Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 35Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024冲洗桥可能故障:DFS-测试失败消毒阀漏气透析器接头膜片/密封圈漏气VDE,PDA 或 BLD 等部件可能漏气机器吸消毒液量不足,电导度过低等吸管端口没有完全沉入消毒液吸管端口滤网堵塞消毒液桶空了消毒阀等部件漏气(检查更换弹簧密封圈等)Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 36Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024DFS 测试失败用软管旁路透析器接头软管(如图连接),从而避免冲洗桥内部件(消毒阀、透析器接头、软管)对DFS测试的影响。如果再次测试DFS通过说明消毒阀或透析器接头漏气。消毒阀和透析器接头及软管Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 37Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024关注 位移传感器MSBK1、MSBK2 和 除气泵EP,正压泵FPE及负压泵FPAFPA泵速过快内部水路不通畅或水路漏气FPA泵头老化FPE泵速过快伴有电导度、温度报警水路不通场或排水管打折突然缺水,内部漏水/漏气等(停止加热并泵停转)FPE泵头老化EP 转速达 3000 rpm泵头或RVE除气比例阀老化,或除气压力PE故障水路漏气位移传感器线圈 MSBK1、MSBK2或信号放大板故障工作范围 15000 至 30000 s之间(总是对称变化)平衡腔(膜移动)Dialog+DFS 透析液通路漏气测试透析液通路漏气测试 38Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024DFS 漏气测试漏气测试 HDF OnlineCode LLC-1502x-1599x Online超净滤器的破裂相关的安全测试,机内置换液系统的漏气测试,附加阀门 VBE/VSAE/VSAA的漏气测试.完整性测试:在负压低于-500 mmHg时 空气不能通过超净滤器内的半透膜.检测 HDF 滤器是否破膜:滤器内一侧充满空气;另一侧调节压力到 5 mS/cm可能故障:定标电导度是零点定标错误。Code LLC-2110 x-2199x 47Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024温度传感器测试温度传感器测试透析液应可加热到 +41 C监测板可识别到高温度点。可能故障:温度传感器定标错误或传感器故障Code LLC-2202x-2299x 48Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/20240102030405060判断接收信号KS临界值报警水平SAD 测试测试测试水平=KS+5每1.2 秒发出一次测试脉冲.LED会指示信号发出LED 不亮:SAD 故障LED 常亮:监测到空气Code LLC-3002x-3199x 49Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024SAD 测试测试Code LLC-3002x-3099x SAD 测试分为两个步骤1.SAD 水平测试 测量测试水平与定标水平进行比较。重启动机器或重新定标SAD。如果已经放入血路管,不会影响该测试。监测板测试步骤 30000-30009 水平测试2.计数测试检查测试脉冲的长短。测试脉冲是由控制板发出的测试信号,监测板同时监测接收计数。计数失败则说明LLC,LLS 或 SAD硬件故障 50Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024血路压力传感器测试血路压力传感器测试PA 和 PV的值进行比较PA和PV的差别不应高于 40 mmHgPA 和 PV 的值将通过内部电阻变化提高到 180 mmHg(仅适用于 且使用3型监测板的机器)再次比较可能故障:压力传感器定标错误或传感器故障没有连接测量或保护罩堵塞,管路故障Code LLC-3202x-3299x 51Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024血泵测试血泵测试血泵转速 200 ml/min 监测信号通过光电二极管识别正确的血泵转速可能故障:泵没有转动定标错误 监测信号识别故障Code LLC-3302x-3320 x 52Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024血路部分压力测试血路部分压力测试可能故障:来自控自制板或监测板的SAKV控制信号故障SAKV 装配故障(如间隙过大)血泵头故障,泵管漏气传感器或管路部分漏气监测板发出信号关闭静脉安全夹(SAKV),同时血泵转动产生高于 400 mmHg的压力血泵停转,控制板发信号控制 SAKV监测板发出信号释放 SAKV,控制板信号保持SAKV关闭。PV压力应保持高于 150 mmHg,PV压降速率 270 mmHg 的压力 PA压力值在10秒内降低不可大于20 mmHgCode LLC-4002x-4099x 可能的故障:BPV 泵头/泵管漏气管路或保护罩漏气DF 或 HDF 滤器漏气DDE 功能故障 或旁路微孔故障(0.7 mm)FPE 和FPA 间驱动力差别过大 54Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024消毒阀门消毒阀门 VD测试测试阀门动作和传感器的测试LLC 打开和关闭阀门,LLS 必需探测到传感器反馈信号的变化。Code LLC-3710 x-3799x 55Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024挂袋式挂袋式HDF机器机器(仅仅HDF选项被选中的机器适用选项被选中的机器适用)置换液泵 BPV转动(min.1.5 转)监测板必须能够通过光电二极管正确检测到泵转动Code LLC-3402x-3599x 通过测试电阻测试秤的误差监测板检测出的误差需小于 4%转动提供流速(80 ml/min 和 10 ml/min)监测板必需能够通过流量计正确检测到水流控制信号禁止超滤(UF超滤泵停转)监测板必需能够通过流量计正确检测到此时无水流 56Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024该测试是为了避免对病人感染的风险,保证所有水路都被充分消毒和冲洗而检测VVB和VBICP阀门的。消毒结束后,如果测试失败,可在消毒历史记录中查看。VVB valvesVBICP valvesLAB 2 chamber消毒程序中的消毒程序中的VBICP自检自检 57Authors:Guenter NissenHeiko RiemenschneiderTraining document,no update service.This document may not be copied,partly or whole,or made be accessible to third parties without our permission and remains the property of B.Braun Medizintechnologie GmbH with all rights.03/05/2024该自检分为两步:1.VVB 和和 VBICP的漏气测试的漏气测试2.VBICP打开的通透性测试打开的通透性测试消毒程序中的消毒程序中的VBICP自检自检可能故障可能故障:VBICP 或 VVB 漏气,或 VBICP 不能打开或堵塞FPA 驱动力高于 FPE太多(如FPE老化或堵塞)VBKO 不能打开没有水流从除气通路进入干粉筒支架水路(水路故障,DBK)HDF online 滤器充满空气
展开阅读全文
相关资源
相关搜索

最新文档


当前位置:首页 > 图纸专区 > 课件教案


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!