Biopotential-Electrodes:生物电的电极资料课件

上传人:文**** 文档编号:240744595 上传时间:2024-05-04 格式:PPT 页数:47 大小:5.25MB
返回 下载 相关 举报
Biopotential-Electrodes:生物电的电极资料课件_第1页
第1页 / 共47页
Biopotential-Electrodes:生物电的电极资料课件_第2页
第2页 / 共47页
Biopotential-Electrodes:生物电的电极资料课件_第3页
第3页 / 共47页
点击查看更多>>
资源描述
Electrode Electrolyte Interface Electrode Electrolyte(neutral charge)C+,A-in solutionCCCA-A-C+C+e-e-Current flowC+:CationA-:Anione-:electron Fairly common electrode materials:Pt,Carbon,Au,Ag,Electrode metal is use in conjunction with salt,e.g.Ag-AgCl,Pt-Pt black,or polymer coats(e.g.Nafion,to improve selectivity)Electrode Electrolyte InterfaceGeneral Ionic Equationsa)If electrode has same material as cation,then this material gets oxidized and enters the electrolyte as a cation and electrons remain at the electrode and flow in the external circuit.b)If anion can be oxidized at the electrode to form a neutral atom,one or two electrons are given to the electrode.a)b)Current flow from electrode to electrolyte:Oxidation(Loss of e-)Current flow from electrolyte to electrode:Reduction(Gain of e-)The dominating reaction can be inferred from the following:Half Cell PotentialA characteristic potential difference established by the electrode and its surrounding electrolyte which depends on the metal,concentration of ions in solution and temperature(and some second order factors).Half cell potential cannot be measured without a second electrode.The half cell potential of the standard hydrogen electrode has been arbitrarily set to zero.Other half cell potentials are expressed as a potential difference with this electrode.Reason for Half Cell Potential:Charge Separation at InterfaceOxidation or reduction reactions at the electrode-electrolyte interface lead to a double-charge layer,similar to that which exists along electrically active biological cell membranes.Measuring Half Cell PotentialNote:Electrode material is metal+salt or polymer selective membraneSome half cell potentialsStandard Hydrogen electrodeNote:Ag-AgCl has low junction potential&it is also very stable-hence used in ECG electrodes!PolarizationIf there is a current between the electrode and electrolyte,the observed half cell potential is often altered due to polarization.OverpotentialDifference between observed and zero-current half cell potentialsResistanceCurrent changes resistance of electrolyte and thus,a voltage drop results.ConcentrationChanges in distributionof ions at the electrode-electrolyte interfaceActivationThe activation energy barrier depends on the direction of current and determines kineticsNote:Polarization and impedance of the electrode are two of the most important electrode properties to consider.Nernst EquationWhen two aqueous ionic solutions of different concentration are separated by an ion-selective semi-permeable membrane,an electric potential exists across the membrane.For the general oxidation-reduction reactionThe Nernst equation for half cell potential is where E0:Standard Half Cell Potential E:Half Cell Potential a :Ionic Activity(generally same as concentration)n :Number of valence electrons involvedNote:interested in ionic activity at the electrode(but note temp dependencePolarizable and Non-Polarizable ElectrodesPerfectly Polarizable ElectrodesThese are electrodes in which no actual charge crosses the electrode-electrolyte interface when a current is applied.The current across the interface is a displacement current and the electrode behaves like a capacitor.Example:Ag/AgCl ElectrodePerfectly Non-Polarizable ElectrodeThese are electrodes where current passes freely across the electrode-electrolyte interface,requiring no energy to make the transition.These electrodes see no overpotentials.Example:Platinum electrodeExample:Ag-AgCl is used in recording while Pt is use in stimulation Use for recordingUse for stimulationAg/AgCl ElectrodeAg+Cl-Cl2Relevant ionic equationsGoverning Nernst EquationSolubility product of AgClFabrication of Ag/AgCl electrodes1.Electrolytic deposition of AgCl2.Sintering process forming pellet electrodesEquivalent CircuitCd :capacitance of electrode-eletrolyte interfaceRd :resistance of electrode-eletrolyte interfaceRs :resistance of electrode lead wireEcell :cell potential for electrodeFrequency ResponseCorner frequencyRd+RsRsElectrode Skin InterfaceSweat glandsand ductsElectrodeEpidermisDermis andsubcutaneous layerRuEheRsRdCdGelReEseEPRPCPCeStratum CorneumSkin impedance for 1cm2 patch:200k 1Hz200 1MHzAlter skin transport(or deliver drugs)by:Pores produced by laser,ultrasound or by iontophoresis100 m100 mNerve endingsCapillaryMotion ArtifactWhyWhen the electrode moves with respect to the electrolyte,the distribution of the double layer of charge on polarizable electrode interface changes.This changes the half cell potential temporarily.WhatIf a pair of electrodes is in an electrolyte and one moves with respect to the other,a potential difference appears across the electrodes known as the motion artifact.This is a source of noise and interference in biopotential measurementsMotion artifact is minimal for non-polarizable electrodesBody Surface Recording Electrodes1.Metal Plate Electrodes(historic)2.Suction Electrodes1.(historic interest)3.Floating Electrodes4.Flexible ElectrodesElectrode metalElectrolyteThink of the construction of electrosurgical electrodeAnd,how does electro-surgery work?Commonly Used Biopotential ElectrodesMetal plate electrodesLarge surface:Ancient,therefore still used,ECGMetal disk with stainless steel;platinum or gold coated EMG,EEG smaller diametersmotion artifactsDisposable foam-pad:Cheap!(a)Metal-plate electrode used for application to limbs.(b)Metal-disk electrode applied with surgical tape.(c)Disposable foam-pad electrodes,often used with ECGCommonly Used Biopotential ElectrodesSuction electrodes-No straps or adhesives required-precordial(chest)ECG-can only be used for short periods Floating electrodes-metal disk is recessed-swimming in the electrolyte gel-not in contact with the skin-reduces motion artifactSuction ElectrodeDouble-sidedAdhesive-taperingInsulatingpackageMetal diskElectrolyte gelin recess(a)(b)(c)Snap coated with Ag-AgClExternal snapPlastic cupTackPlastic diskFoam padCapillary loopsDead cellular materialGerminating layerGel-coated spongeCommonly Used Biopotential ElectrodesFloating ElectrodesReusableDisposable(a)Carbon-filled silicone rubber electrode.(b)Flexible thin-film neonatal electrode.(c)Cross-sectional view of the thin-film electrode in(b).Commonly Used Biopotential ElectrodesFlexible electrodes-Body contours are often irregular-Regularly shaped rigid electrodes may not always work.-Special case:infants-Material:-Polymer or nylon with silver -Carbon filled silicon rubber (Mylar film)Internal ElectrodesNeedle and wire electrodes for percutaneous measurement of biopotentials(a)Insulated needle electrode.(b)Coaxial needle electrode.(c)Bipolar coaxial electrode.(d)Fine-wire electrode connected to hypodermic needle,before being inserted.(e)Cross-sectional view of skin and muscle,showing coiled fine-wire electrode in place.The latest:BION implanted electrode for muscle recording/stimulationAlfred E.Mann FoundationFetal ECG ElectrodesElectrodes for detecting fetal electrocardiogram during labor,by means of intracutaneous needles(a)Suction electrode.(b)Cross-sectional view of suction electrode in place,showing penetration of probe through epidermis.(c)Helical electrode,which is attached to fetal skin by corkscrew type action.Electrode ArraysExamples of microfabricated electrode arrays.(a)One-dimensional plunge electrode array,(b)Two-dimensional array,and(c)Three-dimensional arrayContactsInsulated leads(b)BaseAg/AgCl electrodesAg/AgCl electrodesBaseInsulated leads(a)Contacts(c)TinesBaseExposed tipMicroelectrodesWhy Measure potential difference across cell membraneRequirementsSmall enough to be placed into cellStrong enough to penetrate cell membraneTypical tip diameter:0.05 10 micronsTypesSolid metal-Tungsten microelectrodesSupported metal(metal contained within/outside glass needle)Glass micropipette-with Ag-AgCl electrode metalIntracellularExtracellularMetal MicroelectrodesExtracellular recording typically in brain where you are interested in recording the firing of neurons(spikes).Use metal electrode+insulation-goes to high impedance amplifiernegative capacitance amplifier!Microns!RCMetal Supported Microelectrodes(a)Metal inside glass(b)Glass inside metalGlass MicropipetteA glass micropipet electrode filled with an electrolytic solution(a)Section of fine-bore glass capillary.(b)Capillary narrowed through heating and stretching.(c)Final structure of glass-pipet microelectrode.Intracellular recording typically for recording from cells,such as cardiac myocyteNeed high impedance amplifiernegative capacitance amplifier!heatpullFill with intracellular fluid or 3M KClAg-AgCl wire+3M KCl has very low junction potential and hence very accurate for dc measurements(e.g.action potential)Electrical Properties of MicroelectrodesMetal microelectrode with tip placed within cellEquivalent circuitsMetal MicroelectrodeUse metal electrode+insulation-goes to high impedance amplifiernegative capacitance amplifier!Electrical Properties of Glass Intracellular MicroelectrodesGlass Micropipette MicroelectrodeStimulating Electrodes Cannot be modeled as a series resistance and capacitance (there is no single useful model)The body/electrode has a highly nonlinear response to stimulation Large currents can cause Cavitation Cell damage HeatingTypes of stimulating electrodes1.Pacing2.Ablation3.DefibrillationFeaturesPlatinum electrodes:Applications:neural stimulationModern day Pt-Ir and other exotic metal combinations to reduce polarization,improve conductance and long life/biocompatibilitySteel electrodes for pacemakers and defibrillatorsIntraocular Stimulation ElectrodesReference:Lutz Hesse,Thomas Schanze,Marcus Wilms and Marcus Eger,“Implantation of retina stimulation electrodes and recording of electrical stimulation responses in the visual cortex of the cat”,Graefes Arch Clin Exp Ophthalmol(2000)238:840845In vivo neural microsystems(FIBE):challengeIn vivo neural microsystems(FIBE):biocompatibility-variantIn vivo neural microsystems(FIBE):state of the artNeural microelectrodesMEMS-MicrosystemsInstrumentation for neurophysiologyNeural MicrosystemsIntroduction:neural microsystemsExternal electrodesSubdural electrodesMicro-electrodesMicrosensorsHuman levelAnimal levelTissue slice levelCellular levelIntroduction:types of neural microsystems applicationsIn vivo applicationsIn vitro applicationsMicroelectronic technologyfor MicroelectrodesBonding padsSi substrateExposed tipsLead viaChannelsElectrodeSilicon probeSilicon chipMiniatureinsulatingchamberContactmetal filmHoleSiO2 insulatedAu probesSilicon probeExposedelectrodesInsulatedlead vias(b)(d)(a)(c)Different types of microelectrodes fabricated using microfabrication/MEMS technologyBeam-lead multiple electrode.Multielectrode silicon probeMultiple-chamber electrodePeripheral-nerve electrodeMichigan Probes for Neural RecordingsNeural Recording MicroelectrodesReference:acreo.se/acreo-rd/IMAGES/PUBLICATIONS/PROCEEDINGS/ABSTRACT-KINDLUNDH.PDFIn vivo neural microsystems:3 examplesUniversity of MichiganSmart comb-shape microelectrode arrays for brain stimulation and recordingUniversity of Illinois at Urbana-ChampaignHigh-density comb-shape metal microelectrode arrays for recordingFraunhofer Institute of Biomedical(FIBE)EngineeringRetina implantMulti-electrode Neural RecordingReference:nottingham.ac.uk/neuronal-networks/mmep.htmReference:cyberkineticsinc/technology.htmWPIs Nitric Oxide NanosensorNitric Oxide Sensor Developed at Dr.Thakors Lab,BME,JHU Electrochemical detection of NOLeft:Schematic of the 16-electrode sensor array.Right:Close-up of a single site.The underlying metal is Au and appears reddish under the photoresist.The dark layer is C(300m-x-300m)Cartoon of the fabrication sequence for the NO sensor array A)Bare 4”Si wafer B)5m of photoresist was spin-coated on to the surface,followed by a pre-bake for 1min at 90C.C)The samples were then exposed through a mask for 16s using UV light at 365nm and an intensity of 15mW/cm2.D)Patterned photoresist after development.E)20nm of Ti,150nm of Au and 50nm of C were evaporated on.F)The metal on the unexposed areas was removed by incubation in an acetone bath.G)A 2nd layer of photoresist,which serves as the insulation layer,was spun on and patterned.H)The windows in the second layer also defined the microelectrode sites.ABCDHGFENO Sensor CalibrationNO Sensor CalibrationMultichannel NO Recordings谢谢你的阅读v知识就是财富v丰富你的人生
展开阅读全文
相关资源
相关搜索

最新文档


当前位置:首页 > 办公文档 > 教学培训


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!