ACS1000变频器培训

上传人:沈*** 文档编号:231255543 上传时间:2023-08-31 格式:PPT 页数:46 大小:5.10MB
返回 下载 相关 举报
ACS1000变频器培训_第1页
第1页 / 共46页
ACS1000变频器培训_第2页
第2页 / 共46页
ACS1000变频器培训_第3页
第3页 / 共46页
点击查看更多>>
资源描述
ACS1000ACS1000变频器培训变频器培训900 mm2000 mm4200 mm for W1 frame size4700 mm for W2 and W3 frame sizeWater Cooled Range:水冷适用范围水冷适用范围2-6 MVA;2.3,3.3 and 4.16kV;Product Overview 产品介绍产品介绍ACS1000 Water CooledACS1000 Water Cooled 水冷型ACS1000432105100020003000400050006000aircooledwatercooled400 kVA2000 kVA6000 kVA6000 kVA3600 kVAPower kVAOutput VoltagekV4.16 kV3.3 kV2.3 kVPortfolio 适用范围对比图适用范围对比图Product Overview 产品介绍产品介绍ACS1000 Topology-12 pulseACS1000 Topology-12 pulse ACS1000 12脉波拓扑图Product Overview 产品介绍产品介绍隔离变压器隔离变压器整流桥整流桥直流输出直流输出逆变器逆变器滤波器滤波器电机电机Inverter Technology 逆变技术逆变技术ProductIGCT:Integrated Gate Commutated Thyristor IGCT:集成门极触发晶闸管集成门极触发晶闸管IGCT:The ideal switch for MV applications IGCT:理想的中压开关器件理想的中压开关器件We designed IGCT for the unique needs of the MV Drive Market.专为中压传动市场设计的专为中压传动市场设计的We deliver all the benefits of IGBTs and more,with the added robustness required for MV Drive applications.继承了继承了IGBT的所有优点的所有优点,同时增加了中同时增加了中压传动的特殊功能压传动的特殊功能Product Overview 产品介绍产品介绍IGCT ProductFast switching comparable to IGBTs 与与IGBT相媲美的快速开关性相媲美的快速开关性Low switching losses 低开关损耗低开关损耗Low on state losses 低导通损耗低导通损耗Homogeneous switching 均匀开关性均匀开关性Snubberless 无需缓冲电路无需缓冲电路Integrated free wheeling diode 集成续流二极管集成续流二极管Highly reliable 高可靠性高可靠性Advanced IGCT switching device combines the fast switching of IGBTs with the proven reliability of GTOs先进的先进的IGCT是结合是结合IGBT快速性和快速性和GTO高可靠性的开关器件高可靠性的开关器件 Instantaneous switching frequency:up to 20 kHz 瞬时开关频率高达瞬时开关频率高达20KHzSwitching time(turn off):1 s 开关时间(关断):开关时间(关断):1 sdi/dt:up to 4kA/s 电流变化率高达电流变化率高达4kA/s dv/dt:up to 10-20 kV/s 电压变化率高达电压变化率高达10-20 kV/sAC blocking voltage:up to 6kV 交流阻断电压高达交流阻断电压高达6kVDC blocking voltage:up to 3.9kV 直流阻断电压高达直流阻断电压高达3.9kVFeatures 特性特性Performance 性能性能Product Overview 产品介绍产品介绍Fuse-less Design 无熔断器设计无熔断器设计To protect the system against unnecessary damage,The fuse has to open before the DC link is discharged保护系统不必要的损坏,直流部分保护系统不必要的损坏,直流部分在放电之前必须断开熔断器在放电之前必须断开熔断器Fuses are known to be unreliable熔断器并不可靠熔断器并不可靠A protection IGCT is placed between the rectifier and the DC-link capacitors保护保护IGCT置于整流桥和直流电容置于整流桥和直流电容之间之间Protection IGCTNPNPNPRectifierDC-LinkInverterFilterMotorMCommonModeChokeCommonModeChokeProduct Overview 产品介绍产品介绍Sine Filter Sine Filter 正弦滤波器 No limit on motor cable length.电机电缆长度没有限制电机电缆长度没有限制 No Induced Torque Harmonics.无转距脉动无转距脉动 No Motor Derating.电机无需降容电机无需降容 Decreased motor noise.降低电机噪音降低电机噪音 No voltage reflections.无电压反射无电压反射Product Overview 产品介绍产品介绍Sine Filter Effectiveness Sine Filter Effectiveness 有效的正弦滤波器Product Overview 产品介绍产品介绍逆变器输出逆变器输出电压波形电压波形正弦滤波器输正弦滤波器输出电压波形出电压波形Output Voltage and CurrentOutput Voltage and Current 输出电压和电流波形Product Overview 产品介绍产品介绍输出电压波形输出电压波形输出电流波形输出电流波形Frequency Range Frequency Range 频率范围Nominal Frequency Range:45 82.5 Hz频率范围:45 82.5 HzField Weakening Range:max.1:1.3弱磁范围:max.1:1.3Both conditions are to be fulfilled!两个条件均能实现E.g.:if Fnom=50HzThen Fmax=50*1.3Hz=65HzF Hz45HzPower(and Voltage)TorqueFmaxRequirement:FWP=100%130%and30m transformer cables without CM Choke can result in:当使用超过30m的电缆而不安装共模抑制器会产生以下后果:EMC problems with ACS1000 control(e.g.Link Loss between ADCVI and INT board)电磁兼容问题(ADCVI与INT板之间的连接失败)Medium(or even short)term damage of the transformer insulation 变压器绝缘介质损坏Stress on transformer cables(also EMC problems to ambient due to higher emission)由于加在变压器电缆上的共模电压产生高辐射,致使对周围环境产生电磁兼容问题Risk for Ground Fault tripping 接地故障跳闸的危险Drive Options 传动选配件传动选配件Location in the Water Cooling Unit位于水冷却单元Note:Retrofitting of this option is not possible!注意:这种选择无法升级改造注意:这种选择无法升级改造Drive Options 传动选配件传动选配件3-Way Raw Water Control Valve 3-Way Raw Water Control Valve 三通冷却水控制阀RAMRAM ACS1000风冷变频器的使用寿命风冷变频器的使用寿命 Useful life figures for air cooled converters ACS 1000 逆变器逆变器 Converters:15 years 元器件元器件 Components for which useful life may be less than 15 years:v电池电池 Batteries 2.10 yearsdepending onambient temperaturev电容电容 Inter.Circuit Capacitors 7 yearsdepending on ambient temperature and loadv控制板控制板 Control boards:15 yearsat amb.temp.40Cv电源和驱动板电源和驱动板 7 yearsdepending on ambient Power supplies,Gate units temperaturev风机风机 Fans 4 years系统方案系统方案 System issues主变压器主变压器主变压器主变压器 Main Power TransformerMain Power Transformerv主变压器二次侧两个绕组一个采用星形接法一个采用三角形接法,并存在30 相位移,形成12脉波输入 vThe secondary of the main power trans-former has one wye secondary and one delta secondary.This creates a 30 phase shift between the two 3-phase windings and facilitates 12-pulse input bridge operation.输入整流桥输入整流桥输入整流桥输入整流桥 Input Rectifier BridgesInput Rectifier Bridgesv输入整流桥给直流回路提供直流电压和直流电流。采用串联方式增加直流电压。由于采用串联连接,所有直流电流都流过两组桥。vThe input rectifier bridges provide DC voltage and current to the DC link.They are wired in series such that their voltages are additive.All DC bus current flows through both bridges due to the series connection.IGCTIGCT的预充电和保护开关功能的预充电和保护开关功能的预充电和保护开关功能的预充电和保护开关功能IGCT Precharge and Protection SwitchesIGCT Precharge and Protection Switchesv开始时IGCT处于开路,所以上电后通过预充电电阻向直流回路充电。一旦直流回路电压达到79%的额定电压,IGCT导通。一旦检测到故障,IGCT关断以保护整流桥。vInitially these IGCT devices are open so that when power is applied the DC link charges through the precharge resistors.Once the DC link voltage reaches 79%voltage these switches close and provide the main connection between the input rectifier bridges and the DC link.In the event that a fault is sensed,they open to prevent the rectifier bridge from feeding into the fault.NPVDC+VDC-预充电电阻预充电电阻预充电电阻预充电电阻 Precharge ResistorsPrecharge Resistors预充电电阻限制上电时流入直流电容的电流。一旦IGCT导通,尽管预充电电阻保留在电路中但不提供任何作用。The precharge resistors limit the current that flows into the main DC link capacitors when power is initially applied.Once the precharge and protection switches are closed,although the precharge resistors remain in the circuit,they dont provide any further function.NPVDC+VDC-直流共模抑制器直流共模抑制器直流共模抑制器直流共模抑制器 DC Link Common Mode ChokeDC Link Common Mode Choke直流共模抑制器的功能如同变压器,与共模抑制电阻一起对由主变压器和进线电缆引入的共模电压和电流产生抑制作用。共模抑制器在共模电压回路中有效地串进了并联的电阻和电抗。The DC link common mode choke functions like a transformer and works in conjunction with the common mode damping resistor to provide voltage damping and current limitation of the common mode voltages and currents experienced by the main power transformer and input cabling.The common mode choke effectively inserts a paralleled resistance and reactance in series with the common mode voltage source.NPVDC+VDC-LCLC滤波器滤波器滤波器滤波器 LC FilterLC FilterLC滤波器负责对逆变器输出进行滤波。大大地降低加到电机上电压的谐波成分,因此允许应用于标准电机。同时消除了高dv/dt 的影响,以至于电压反射和电机绝缘的问题得到根本解决。The LC filter is responsible for filtering the inverter output.It greatly reduces the harmonic content of the waveform applied to the motor and thus allows a standard motor to be applied.It also eliminates all high dv/dt effects such that voltage reflection and motor insulation stress problems are totally eliminated.CDP312控制盘控制盘 Control Panel CDP 312安装在变频器门板上安装在变频器门板上 Mounted on converter door本地操作传动设备本地操作传动设备 Local operation of drive监控实际值和给定值监控实际值和给定值 Monitoring actual and reference values宏和参数设置宏和参数设置 Macros and parameter settings故障记忆监控故障记忆监控 Fault memory monitoring参数上载与下载参数上载与下载 Parameter up/down load通过通过RS485与与AMC3板连接(板连接(Modbus协议)协议)RS485 connection with AMC3 board (Modbus link)1 L 1242 rmp ISPEED 1242 rmpCURRENT 76 APOWER 55%ACTPARFUNCDRIVEENTERLOCREMRESETREFI08月2日变频器故障现场检修所有柜门为铰接并配门锁。所有柜门为铰接并配门锁。功率单元的柜门与接地开关还有主电路断路器连锁,从而保证功率单元的柜门与接地开关还有主电路断路器连锁,从而保证只有在断开只有在断开主电源,直流电容放电结束并且接地开关接地后,功率单元的主电源,直流电容放电结束并且接地开关接地后,功率单元的柜门才能打柜门才能打开。同样,在关好柜门之前变频器功率单元无法上电。开。同样,在关好柜门之前变频器功率单元无法上电。控制单元和冷却单元(水冷型)的柜门没有和电气连锁,可以控制单元和冷却单元(水冷型)的柜门没有和电气连锁,可以随时打开。随时打开。高压母排安装在控制单元后面,有防护隔离门隔离,防止触电。高压母排安装在控制单元后面,有防护隔离门隔离,防止触电。所有其它附加单元柜体的柜门锁均单独安装,不包括在机电连所有其它附加单元柜体的柜门锁均单独安装,不包括在机电连锁中,这些锁中,这些门锁开关被连锁到跳闸回路中,一旦在变频器运转中打开柜门,门锁开关被连锁到跳闸回路中,一旦在变频器运转中打开柜门,主回路断主回路断路器会立刻跳闸。路器会立刻跳闸。本地控制如果变频器处于本地控制模式,可以通过变频器正面门板上的按钮和CDP 312 控制盘进行本地操作。在本地控制模式,不接受任何远程控制命令。远程控制如果选择远程控制模式,不接受变频器正面门板上的按钮和CDP 312 控制盘发出的命令。取而代之的是接受来自远程控制台的数字输入信号,包括主回路断路器的闭合/断开命令和传动的起动/停止命令等。速度给定由模拟输入信号提供。所有的远程控制信号可以通过可选的总线接口与变频器进行交换。通过设置数字输入“DISABLE LOCAL”可以禁止本地与远程控制模式的切换。ACS1000操作规程一、中控停车后必须立即通知电气到电力室,根据循环水温度在10分钟内逐步关掉外循环水,达到既能将运行热量逐步带走又严禁关闭过快设备出现急冷现象,防止温差大出现结露。每次未及时通知电气考核操作员30-50元,电气值班员接到停车命令后必须按规程关闭外部循环水,完成后在值班记录上写清操作人,操作时间等事项,出现一次未关闭考核当班班长30-50元,记录不全一次考核记录人10元。造成事故者根据事故大小另行考核。二、停车后无电气通知整流变不得分闸,以利用直流系统工作热量提高柜内温度,消除结露现象。出现一次分闸考核操作员30-50元。电气维护通知分闸除外,但操作员要做好记录,记录写明分闸时间、电气人员姓名、维护完成时间、合闸时间等事项。三、长期停车后开车前当班电气值班员必须完成如下操作:1、变频器整流变分闸。变频器面板安全放电指示灯亮起后将变频器接地刀闸打至接地位置。2、用专用钥匙打开变频器柜门,详细检查内部电抗器、直流和逆变模块等器件有无结露现象,内循环水系统有无漏水现象,各高压瓷 瓶有无放电闪络现象,水泵风机工作是否正常,各控制板工作显示是否正常等,详细检查结果登记在电气科变频器检查表上,填写后上交电气科备档。3、检查全部正常后关闭变频器柜门,接地刀闸打至分断位置,详细检查变频器面板报警及故障信息,必须保证当日信息全部检查完毕,确认正常后联系中控远程合闸送电。4、变频器初次开启后值班员必须严密监视运行温度,保证处于30-35度的范围工作。待运行温升稳定后方可离开。以上每项检查项漏检一项考核责任人10元。未检查即上电每次考核责任人50元,出现事故另行考核。四、平时运行中操作员要严密监视运行温度,低于30度、高于36度要立即联系电气调整水温。使运行温度时刻保持在30-35度的合理范围内工作。五、在平时操作中应遵循缓加速、慢减速原则进行,防止高温风机给定转速大幅低于尾排风机转速的情况出现,防止出现过速引起的过电压故障。六、电气科负责安装温湿度自动控制系统,同时温湿度异常信号接点进入中控显示。确保柜内温湿度时刻控制在合理范围内。结束结束
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 办公文档 > 工作计划


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!