武汉理工大学毕业设计摘 要本设计为教学楼。设计依据为毕业设计任务书,以新规范为准进行设计。结构设计顺序为:结构布置、恒荷载、活荷载、风荷载及地震荷载作用内力计算,荷载组合效应,框架梁、柱的配筋,楼板计算,楼梯计算,基础配筋的计算。本设计中,板采用弹性理论的计算方法,框架选取典型的一榀,恒荷载作用下的内力计算采用力矩分配法,活荷载作用下的内力计算采用分层法,风荷载和地震荷载采用D值法。关键字:框架结构ABSTRACTThis design is about a building for school. It is according to Graduation design specifications and the latest norms. The order of the structural design is :The layout of the structure ,dead loads、living loads、wind loads and earthquake functions calculation, load effect of making up, reinforcing bars disposition for the frame beam and post, the floors calculation, the stairs calculation, the foundations calculation for reinforcing bars disposition. In this design, the board adopts the computing technology of elastic theory, choose a typical Pin in the frame ,to calculate internal force caused by vertical loads, divide one layer of laws is adopted; to calculate the wind loads and earthquake function, the law of D value is adopted.Key word: portal frame construction绪论毕业设计是学生学完全部课程后的一个重要实践性教学环节,也是一次将已学知识应用于工程实际的综合训练。通过毕业设计使学生了解一般民用建筑设计方法,掌握建筑构造的处理;掌握多层框架结构房屋的结构选型和布置,掌握多层框架及部分结构构件的计算;能绘制房屋施工图,熟悉房屋设计的全过程;掌握多层框架结构房屋单位工程施工组织设计的一般方法。通过毕业设计的训练,使学生初步具有处理工程问题的能力。进行毕业设计时要求我们能理论联系实际,注意培养独立思考、分析问题与解决问题的能力。通过三个多月的独立设计,我认识到毕业设计的目的:1)巩固、加深基础和专业知识。 通过毕业设计对于已经学过的基础知识如数学、结构力学、计算机等和专业知识如钢结构、混凝土结构设计原理、混凝土结构设计、建筑抗震、土木工程施工、房屋建筑学等专业知识进一步系统巩固、加深和拓展。2)提高综合运用基础和专业知识和基本技能的能力。 过去所学的数学、力学基础知识和结构设计等知识在毕业设计中要综合运用。毕业设计具有综合性,通过设计也就提高了综合运用这些知识的能力,并培养创新能力。在毕业设计所遇到的问题和需要解决的问题,是需要具有综合运用所学知识的能力,而不是过去所学单纯某一门课的知识所能解决,这样就锻炼了综合运用所学基础知识、专业知识的能力。 3)熟悉土木工程专业设计的程序和方法,了解我国有关土木工程建筑的方针和政策。通过设计了解一个设计任务从任务书到政府建设部门批文,到委托设计和进行施工的建设程序。熟悉如何使用专业的技术规范和规定,如建筑防火、抗震、钢结构、混凝土结构、地基基础、技术规范等。 4)针对要解决的问题,学习和熟悉如何搜集国内外资料,了解国内外的现状和水平。搜集国内外资料。 5)学习调查研究的方法,培养深入细致、联系实际,从经济,技术观点全面分析和解决问题,独立思考独立工作的能力。调查研究,可以深入到实际了解已有的设计存在的问题,在设计中克服这些缺点,改进设计。 6)了解工程中常用做法,增强工程意识提高工程实践能力。每人独立、系统完成一个工程设计以期掌握一个工程的全过程设计。 在接下来的设计中,我将会在老师的指导以及参阅各种资料、规范下,全面综合的解决设计过程中所遇到的问题。从而达到设计的完整和合理。1.结构选型1.1.结构形式本工程为六层教学楼,首层层高4.2m,其余各层层高为3.9m ,按设计要求,采用钢筋混凝土现浇框架体系.1.2.基础一层墙下设基础圈梁,截面尺寸为250mm400mm,基础圈梁下设条形基础,外柱下做独立基础,内柱做联合基础,基础底标高统一取为2.000m.1.3.墙体材料外墙采用250mm加气混凝土砌块,内墙采用200mm加气混凝土砌块.1.4.楼梯结构采用钢筋混凝土板式楼梯1.5.变形缝设置(1)伸缩缝该工程长边总长为50.4m,根据钢筋混凝土规范,对于框架承重结构,现浇式超过78m,整体式超过62m需要设置变形缝,故该工程不需要设缝.(2)沉降缝本综合办公楼采用的是框架结构,考虑到各种荷载组合后不会很大,基础承载力较好,故不必设置(3)抗震缝由于抗震等级小,结合建筑结构形式不需要设置.2.构件选型2.1.梁、板、柱截面尺寸确定2.1.1梁根据混凝土结构设计,根据梁截面高度可按跨度的1/14-1/8估算,宽高比一般为1/3-1/2,主梁高度不小于200mm,梁截面高度与宽度的比值不宜大于4,以保证平面外的稳定.2.1.2板根据混凝土结构设计A.双向板:一般不做刚度验算时板的最小高度为h=(1/50-1/40)L(L为双向板的短向跨度),且应满足h80mmB.单向板:一般不做感度验算时板的最小高度为h=( 1/40-1/30)L(L为单向板的标志跨度),且应满足h60mm2.1.3柱框架柱的截面边长不宜小于250mm,圆柱的截面直径不宜小于350mm,剪跨比不宜小于2,截面的高度与宽度比不宜大于3。为了减少构件的类型,以简化施工,多层房屋中柱子截面沿房屋高度不宜改变。2.2.结构布置及计算简图取6 轴上的一榀框架计算。框架柱固于基础顶面,框架梁与柱刚接,由于各层柱的截面尺寸不变,故梁的跨度等于柱截面型心轴线之间的距离,底层柱高以基础顶面算至二层楼面,基础顶标高根据地质条件,室内外高差,定为-0.60m,二层楼面标高为4.200m,故底层柱高为4.800m,其余各层柱高从楼面算至上一层楼面(即层高),均为3.900m,由此可以给出框架的计算简图.2.3.框架梁柱的线刚度计算2.3.1梁对于中框架梁取I=2I0,选用C25混凝土, E=2.80107KN/m2 2.3.2柱 令其余各层柱 i=1.0 ,则其余各杆件的相对线刚度为框架梁柱的相对线刚度如图所示,作为计算各节点杆端弯矩分配系数的依据.框架计算简图3.荷载计算3.1 恒荷载标准值计算3.1.1屋面防水层(刚性)30厚C20细石混凝土防水 1.0防水层(柔性)三毡四油铺小石子 0.420厚水泥砂浆找平层 0.0220=0.40120厚焦渣找坡层 0.1214=1.68100厚现浇砼板 0.125=2.520厚石灰抹底 0.0217=0.34合计 6.323.1.2楼面110厚水磨石地面: 20厚1:3水泥砂浆找平 0.6510厚混和砂浆天棚抹灰 0.0117=0.17100厚板自重 0.125=2.5合计 3.323.1.3 卫生间楼面10厚水磨石地面三毡四油放水层20厚1:3水泥砂浆找平 1.05100厚现浇钢筋砼板自重 0.1025=2.510厚混和砂浆天棚抹灰 0.0117=0.17合计 3.723.1.4 梁自重 bh=300600梁自重 250.3m(0.60-0.10)=3.7510厚混和砂浆抹灰层 0.01(0.60-0.10+0.30)217=0.27合计 3.72基础梁bh=250400梁自重 250.250.40=2.503.1.5 柱自重bh=400500柱自重 250.400.50=5.00抹灰层:10厚混合砂浆 0.010.50417=0.34合计 5.343.1.6 外纵墙自重 2-6层无窗处 纵墙 180.253.9=17.55水刷石外墙面 3.9m0.5=1.95 水泥粉刷内墙面 3.90.36=1.40合计 20.92-6层C-1,C-3窗处纵墙 180.250.9=6.65塑钢窗 0.352.40=0.84外墙面做法 (3.9-2.4)0.5=0.75内墙面做法 (3.9-2.4)0.36=0.54 合计 6.18底层有门处纵墙 180.25(4.8-2.1-0.6-0.4)=7.65塑钢门 0.352.10=0.74水刷石外墙面 (4.2-2.1)0.5=1.05水泥粉刷内墙面 (4.2-2.1)0.36=0.76 合计 10.20底层C-1,C-3窗处纵墙 180.25(4.8-2.4-0.6-0.4)=12.5塑钢窗 0.352.40=0.84 水刷石外墙面 (4.2m-2.4m)0.5=0.90 水泥粉刷内墙面 (4.2m-2.4m)0.36=0.65合计 8.693.1.7 内墙自重2-6层无门处内墙 180.203.9=14.04水泥粉刷内墙面 23.90.36 =2.80 合计 16.84 2-6层有门处内墙 180.20(3.9m-2.1)=6.48塑钢门 0.352.10=0.74水泥粉刷内墙面 2(3.9-2.1m)0.36 =1.30 合计 8.52底层无门处内墙 180.20(4.8-0.4-0.6)=13.68水泥粉刷内墙面 2(4.8-0.6m-0.4m)0.36 =2.74 合计 16.42底层有门处内墙 180.20(4.8-0.4-0.6-2.1)=6.12塑钢门 0.352.10=0.74水泥粉刷内墙面 2(4.8-0.6m-0.4m-2.1m)0.36 =1.22 合计 8.083.1.8 女儿墙自重女儿墙自重 250.251.2=7.5外墙面 200.021.2=0.4420厚M5混和砂浆内墙面 170.021.2=0.37合计 8.393.2 活荷载标准值计算3.2.1 屋面和楼面活荷载标准值计算根据荷载规范查得:上人屋面: 2.0 不上人屋面: 0.5 楼面:教室 2.0 走廊 2.5 3.2.2 雪荷载Sk=0.4 3.3 竖向荷载下框架受荷总图3.3.1 A-C轴框架梁屋面板传荷载:荷载传递示意图见上恒载:活载:楼面板传荷载:恒载:活载:梁自重:4.02A-C轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.02 +45.93=49.95 活载=板传荷载=7.83楼面梁:恒载=梁自重+板传荷载和墙自重=4.02 +11.55=15.57 活载=板传荷载=6.963.3.2 C-D轴间框架梁屋面板传荷载恒载:6.32 1.52=11.85 活载:2.01.52=3.75 楼面板传荷载恒载:3.321.52=6.23 活载:2.5 1.52=4.69梁自重:4.02C-D轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.02+11.85=15.87 活载=板传荷载=3.75 KN/m楼面梁:恒载=梁自重+板传荷载和墙自重 =4.02+6.23=10.25活载=板传荷载=4.69 KN/m3.3.3 D-E轴间的框架梁屋面板传荷载恒载:活载:楼面板传荷载:恒载:活载:梁自重:4.02D-E轴间框架梁均布荷载为:屋面梁:恒载=梁自重+板传荷载 =4.02+21.98=26 活载=板传荷载=6.96KN/m楼面梁:恒载=梁自重+板传荷载和墙自重 =4.02+11.55 =15.57 活载=板传荷载=6.963.3.4 A轴柱纵向集中荷载的计算顶层柱恒载=8.394.2+4.02(4.2-0.4)+2.1m6.324.25/8=85.35顶层柱活载=板传活载 =2.02.14.2 5/8 =11.03标准层柱恒载=墙自重+梁自重+板传荷载 =6.18(4.2m-0.4m)+4.02(4.2m-0.4m) +3.322.1m4.2m5/8=57.06标准层柱活载=板传活载=2.05/84.2m2.1 =11.03基础顶面恒载=底层外纵墙自重+基础梁自重 =8.69(4.2-0.4m)+2.5(4.2-0.4m) =42.523.3.5 C轴柱纵向集中荷载的计算顶层柱恒载=梁自重+板传荷载=4.02KN/m(4.2m-0.4m)+6.32KN/m22.1m4.2m5/8+6.32KN/m2(1-20.32m2+0.32m3)1.5m4.2m=83.11KN顶层柱活载=板传活载=2.0KN/m22.1m5/84.2m+2.0KN/m2(1-20.322+0.323)1.5m4.2m=21.47KN标准层柱恒载=内墙自重+梁自重+板传荷载=4.02 KN/m(4.2m-0.4m)+3.32 KN/m22.1m5/84.2m+3.32 KN/m2(1-20.322+0.323)1.5m4.2m+16.84 KN/m(2.1m-0.2m)=82.91KN标准层柱活载=板传荷载 =2.02.15/84.2 +2.0(1-20.32m2+0.32m3)4.21.5 =21.47基础顶面恒载=底层内墙无门处自重+基础梁自重=16.42(2.1m-0.2m)+2.5(2.1-0.2)=35.953.3.6 D轴柱纵向荷载计算顶层柱恒载=梁自重+板传荷载=4.02KN/m(4.2m-0.4m)+6.32KN/m22.1m4.2m5/8+6.32KN/m2(1-20.32m2+0.32m3)1.5m4.2m=83.11KN顶层柱活载=板传活载=2.0KN/m22.1m5/84.2m+2.0KN/m2(1-20.322+0.323)1.5m4.2m=21.47KN标准层柱恒载=内墙自重+梁自重+板传荷载=4.02 KN/m(4.2m-0.4m)+3.32 KN/m22.1m5/84.2m+3.32 KN/m2(1-20.322+0.323)1.5m4.2m+16.84 KN/m(4.2m-0.4m)=114.90KN标准层柱活载=板传荷载 =2.02.15/84.2 +2.0(1-20.32m2+0.32m3)4.21.5 =21.47基础顶面恒载=底层内墙无门处自重+基础梁自重=16.42(2.1m-0.2m)+2.5(4.2-0.4)=71.903.3.7 E轴柱纵向荷载计算同A轴竖向荷载见图3.4 风荷载3.4.1 风荷载标准值计算作用在屋面梁和楼面梁节点处的集中风荷载标准值:式中:基本风压 :风压高度系数,地面粗糙度为B :风荷载体型系数,根据建筑物的体型查得 =1.3 :风振系数,建筑高度30。=1.0 :下层柱高 :上层柱高,对顶层为女儿墙高度的2倍 :迎风面宽度,从安全考虑,取B迎=B背=4.2计算过程见表01表01.集中风荷载标准值离地高度Z/m24.150.911.00 1.30 0.353.90 2.40 5.4820.250.841.00 1.30 0.353.90 3.90 6.2616.350.771.00 1.30 0.353.90 3.90 5.7412.450.741.00 1.30 0.353.90 3.90 5.528.550.741.00 1.30 0.353.90 3.90 5.524.650.741.00 1.30 0.354.65 3.90 6.05框架在风荷载作用下受荷图如图09所示(图中数值为标准值)3.4.2 风荷载作用下的位移计算3.4.2.1 侧移刚度见下表横向2-6层D值的计算杆件名称A轴柱0.2789848C轴柱0.55110519D轴柱0.55119519E轴柱0.2789848横向底层D值的计算杆件名称A轴柱0.4929353C轴柱0.70113326D轴柱0.70113326E轴柱0.49293533.4.2.2 风荷载作用下框架侧移计算 水平荷载作用下框架的层间位移计算式中: 第 层的总剪力 第层所有柱的抗侧刚度之和 第层的层间位移第一层的层间位移值求得以后,就可以计算各楼板标高处的侧移值的顶点侧移值,各层楼板的标高处的侧移值是该层以下各层层间侧移之和,顶点侧移是所有各层层间位移之和。层侧移 顶层位移 框架在风荷载作用下侧移的计算见表04风荷载作用下框架侧移计算层次65.485.48587340.00013.91/3900056.2611.74587340.00023.91/1950045.7417.48587340.00033.91/1300035.5223587340.00043.91/975025.5228.52587340.00053.91/780016.0534.57453580.00084.651/6000 侧移验算: 层间侧移最大值 1/60001/550(满足)3.5 地震荷载计算 分层荷载计算 (57.062+82.91+114.90)+20.834+15.576.6+10.253+15.576.6+0.511.032+21.472+(6.966.6+8.71 3+6.96 6.6)=311.93KN+83.32KN+236.27KN+32.5KN+59KN=723.02311.93KN+25.63KN/m4+236.27KN+32.5KN+59=742.22KN恒向框架自振周期需考虑顶部附加地震作用420.24+723.024+742.22=4054.540.854054.54=3446.36结构水平总地震作用标准值,各层横向地震作用及楼层地震剪力见表框架在地震作用下受荷图如图所示图中数值均为标准值地震何荷载作用下位移的计算(1) 侧移刚度见表(2) 地震荷载作用下框架侧移计算见表各层横向地震作用及楼层地震剪力层数63.924.3420.2410211.8328.1628.1653.920.4723.0214749.6140.6668.8243.916.5723.0211929.8332.89101.7133.912.6723.029110.0525.12126.8323.98.7723.026290.2717.34144.1714.654.65742.223451.329.53153.704054.5455742.91地震荷载作用下框架侧移计算层数628.16587340.00053.91/7800568.82587340.00113.91/35454101.71587340.00173.91/22943126.83587340.00223.91/17732144.17587340.00253.91/15601153.70453580.00344.651/13684.荷载作用下框架内力计算4.1恒载作用下框架内力计算4.1.1恒荷载作用下框架的弯矩计算由刚度比求得节点各杆端的弯矩分配系数各节点分配两次即可,传递系数C=1/24.1.2恒荷载作用下框架的剪力计算 4.1.3恒荷载作用下轴力计算已知某节点上柱传来的轴力Nu和左右梁传来的剪力Vl、Vr时,其下柱的轴力恒载作用下的M图、V图、N图如图所示。4.2活荷载做用下框架的内力计算活荷载作用下框架受荷简图如图所示,由于内力计算采用分层法,因而除底层柱外,其他各层柱的线刚度(或相对线刚度)均乘以0.9,并取相应的传递系数1/3(底层的传递系数仍为1/2),分配系数和固端弯矩的计算方法同前,此处省略。4.2.1顶层计算单元(h3.9m)因屋面活荷载较小,不考虑活荷载的最不利组合,将活荷载满跨布置,计算简图如所示4.2.2. 25层计算单元(h3.9m)活荷载满跨布置4.2.3底层计算单元底层满跨布置活荷载时计算结果如图所示:第 72 页 共 72 页上柱下柱左梁右梁上柱下柱左梁右梁上柱下柱左梁右梁下柱上柱0.57 0.44 0.22 0.29 0.49 0.49 0.29 0.22 0.44 0.57 8.54 -217.20 216.38 -8.31 -11.90 11.90 8.31 -94.38 94.38 -8.54 -208.66 -208.66 -208.66 196.17 196.17 196.17 196.17 -74.17 -74.17 -74.17 85.84 85.84 117.89 90.77 -43.75 -56.89 -95.53 36.12 21.51 16.54 -37.34 -48.50 15.65 -21.87 45.38 -8.50 18.06 -47.77 4.20 -18.67 8.27 -9.17 -6.23 -6.23 54.94 54.94 54.94 54.94 -62.24 -62.24 -62.24 -62.24 -0.90 -0.90 3.52 2.71 -12.25 -15.93 -26.76 30.31 18.05 13.88 0.39 0.51 137.06 -145.60 205.77 -81.33 -116.13 30.56 43.76 -82.63 65.70 -57.16 0.36 0.36 0.28 0.17 0.23 0.23 0.38 0.38 0.23 0.23 0.17 0.28 0.36 0.36 5.71 -92.40 91.58 -8.30 -7.69 7.69 11.49 -56.52 56.52 -5.71 -86.69 -86.69 -86.69 75.59 75.59 75.59 75.59 -37.34 -37.34 -37.34 -37.34 50.81 50.81 50.81 31.30 31.30 24.10 -13.08 -17.01 -17.01 -28.57 14.11 8.40 8.40 6.46 -14.13 -18.34 -18.34 58.95 15.65 -6.54 12.05 -28.44 -8.50 7.06 -14.29 10.75 4.20 -7.06 3.23 -9.17 -24.25 68.06 68.06 68.06 -17.84 -17.84 -17.84 -17.84 -6.39 -6.39 -6.39 -6.39 -30.19 -30.19 -30.19 -24.57 -24.57 -18.92 3.09 4.01 4.01 6.74 2.42 1.44 1.44 1.11 8.39 10.90 10.90 65.67 22.37 -93.76 93.64 -41.44 -21.50 -22.46 9.93 20.59 14.04 -56.02 54.02 -16.61 -31.69 0.36 0.36 0.28 0.17 0.23 0.23 0.38 0.38 0.23 0.23 0.17 0.28 0.36 0.36 5.71 -92.40 91.58 -8.30 -7.69 7.69 11.49 -56.52 56.52 -5.71 -86.69 -86.69 -86.69 75.59 75.59 75.59 75.59 -37.34 -37.34 -37.34 -37.34 50.81 50.81 50.81 31.30 31.30 24.10 -13.08 -17.01 -17.01 -28.57 14.11 8.40 8.40 6.46 -14.13 -18.34 -18.34 15.65 15.65 -6.54 12.05 -8.50 -8.50 7.06 -14.29 4.20 4.20 -7.06 3.23 -9.17 -9.17 24.76 24.76 24.76 2.10 2.10 2.10 2.10 -12.95 -12.95 -12.95 -12.95 -15.11 -15.11 -15.11 -8.94 -8.94 -6.88 -0.36 -0.47 -0.47 -0.79 4.89 2.91 2.91 2.24 4.20 5.46 5.46 38.01 38.01 -81.72 90.19 -25.98 -25.98 -30.00 12.41 15.52 15.52 -54.88 49.83 -22.06 -22.06 0.36 0.36 0.28 0.17 0.23 0.23 0.38 0.38 0.23 0.23 0.17 0.28 0.36 0.36 5.71 -92.40 91.58 -8.30 -7.69 7.69 11.49 -56.52 56.52 -5.71 -86.69 -86.69 -86.69 75.59 75.59 75.59 75.59 -37.34 -37.34 -37.34 -37.34 50.81 50.81 50.81 31.30 31.30 24.10 -13.08 -17.01 -17.01 -28.57 14.11 8.40 8.40 6.46 -14.13 -18.34 -18.34 15.65 15.65 -6.54 12.05 -8.50 -8.50 7.06 -14.29 4.20 4.20 -7.06 3.23 -9.17 -9.17 24.76 24.76 24.76 2.10 2.10 2.10 2.10 -12.95 -12.95 -12.95 -12.95 -15.11 -15.11 -15.11 -8.94 -8.94 -6.88 -0.36 -0.47 -0.47 -0.79 0.00 4.89 2.91 2.91 2.24 0.00 4.20 5.46 5.46 38.01 38.01 -81.72 90.19 -25.98 -25.98 -30.00 12.41 15.52 15.52 -54.88 49.83 -22.06 -22.06 0.36 0.36 0.28 0.17 0.23 0.23 0.38 0.38 0.23 0.23 0.17 0.28 0.36 0.36 5.71 -92.40 91.58 -8.30 -7.69 7.69 11.49 -56.52 56.52 -5.71 -86.69 -86.69 -86.69 75.59 75.59 75.59 75.59 -37.34 -37.34 -37.34 -37.34 50.81 50.81 50.81 31.30 31.30 24.10 -13.08 -17.01 -17.01 -28.57 14.11 8.40 8.40 6.46 -14.13 -18.34 -18.34 15.65 16.82 -6.54 12.05 -8.50 -8.88 7.06 -14.29 4.20 3.55 -7.06 3.23 -7.95 -9.17 25.93 25.93 25.93 1.72 1.72 1.72 1.72 -13.60 -13.60 -13.60 -13.60 -13.89 -13.89 -13.89 -9.36 -9.36 -7.21 -0.30 -0.39 -0.39 -0.65 5.14 3.06 3.06 2.35 3.86 5.02 5.02 37.58 38.75 -82.05 90.26 -25.90 -26.28 -29.86 12.66 15.66 15.01 -54.77 49.49 -21.28 -22.50 0.39 0.31 0.30 0.18 0.24 0.19 0.39 0.39 0.19 0.24 0.18 0.30 0.31 0.39 5.71 -92.40 91.58 -8.30 -7.69 7.69 11.49 -56.52 56.52 -5.71 -86.69 -86.69 -86.69 75.59 75.59 75.59 75.59 -37.34 -37.34 -37.34 -37.34 50.81 50.81 50.81 33.64 27.13 25.83 -13.68 -17.76 -14.36 -29.78 14.71 7.09 8.77 6.76 -15.14 -15.90 -19.71 15.65 -6.84 12.92 -8.50 7.36 -14.89 4.20 -7.57 3.38 -9.17 8.81 8.81 11.77 11.77 11.77 11.77 -18.26 -18.26 -18.26 -18.26 -5.79 -5.78 -3.42 -2.62 -2.13 -2.77 -2.24 -4.64 7.19 3.47 4.29 3.31 1.73 2.24 45.87 27.13 -76.03 88.68 -29.03 -16.60 -34.75 11.34 14.76 13.07 -54.03 46.48 -15.90 -26.64 下柱左梁右梁下柱左梁右梁下柱左梁右梁下柱0.54 0.46 0.23 0.27 0.50 0.50 0.27 0.23 0.46 0.54 -28.42 28.42 -2.812.81 -25.26 25.26 15.35 13.07 -5.89 -6.91 -12.81 11.23 6.06 5.16 -11.62 -13.64 -2.95 6.54 5.62 -6.41 -5.81 2.58 1.59 1.36 -2.80 -3.28 -6.08 6.11 3.30 2.81 -1.19 -1.39 16.94 -16.94 26.27 -10.19 -16.08 13.74 9.36 -23.10 14.03 -14.03 5.65 -3.40 3.12 -4.68 上柱下柱左梁右梁上柱下柱左梁右梁上柱下柱左梁右梁上柱下柱0.35 0.35 0.30 0.18 0.21 0.21 0.40 0.40 0.21 0.21 0.18 0.30 0.35 0.35 -25.26 25.26 -3.52 3.52 -25.26 25.26 8.84 8.84 7.58 -3.91 -4.57 -4.57 -8.70 8.70 4.57 4.57 3.91 -7.58 -8.84 -8.84 -1.96 3.79 4.35 -4.35 -3.79 -1.96 0.69 0.69 0.59 -1.47 -1.71 -1.71 -3.26 3.26 1.71 1.71 1.47 -0.59 -0.69 -0.69 9.53 9.53 -19.05 23.67 -6.28 -6.28 -11.13 11.13 6.28 6.28 -23.67 19.05 -9.53 -9.53 3.18 -2.09 2.09 -3.18 上柱下柱左梁右梁上柱下柱左梁右梁上柱下柱左梁右梁上柱下柱0.34 0.37 0.29 0.18 0.21 0.23 0.38 0.38 0.21 0.23 0.18 0.29 0.34 0.37 -25.26 25.26 -3.52 3.52 -25.26 25.26 8.59 9.53 7.33 -3.91 -4.57 -5.00 -8.26 8.26 4.57 4.57 3.91 -7.33 -8.59 -9.53 -1.96 3.67 4.13 -4.13 -3.67 -1.96 0.67 0.73 0.57 -1.40 -1.64 -1.79 -2.96 2.96 1.64 1.79 1.40 -0.57 -0.67 -0.73 9.26 10.26 -19.32 23.62 -6.21 -6.79 -10.61 10.61 6.21 6.79 -23.62 19.32 -9.26 -10.26 5.13 -3.40 3.40 -5.13 4.3风荷载标准值作用下框架内力计算框架在风荷载下的内力用D值法进行计算,其步骤为:(1)求各柱反弯点处的剪力值(2)求各柱反弯点的高度(3)求各柱的杆端弯矩及梁端弯矩(4)求各柱的轴力和梁剪力框架各柱的杆端弯矩、梁端弯矩按下式计算,中柱 边柱 第i层第m柱所分配的剪力为: ,见表框架柱反弯点位置,标准反弯点高度比,是在各层等高、各跨相等、各层梁和柱线刚度都不变的
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 办公文档


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!