建筑环境与设备工程(暖通)毕业设计外文翻译

上传人:j*** 文档编号:70134672 上传时间:2022-04-06 格式:DOC 页数:14 大小:88.50KB
返回 下载 相关 举报
建筑环境与设备工程(暖通)毕业设计外文翻译_第1页
第1页 / 共14页
建筑环境与设备工程(暖通)毕业设计外文翻译_第2页
第2页 / 共14页
建筑环境与设备工程(暖通)毕业设计外文翻译_第3页
第3页 / 共14页
点击查看更多>>
资源描述
南京工程学院 Nanjing Institute Of Technology毕业设计英文资料翻译The Translation Of The English Material Of Graduation Design 学生姓名: 学 号 : 000000000 Name: Number: 000000000 班 级: K暖通091 Class: KNuantong 091 所在学院: 康尼学院 College: Kangni College 专 业: 建筑环境与设备工程 Profession: Building Environment and Equipment Engineering 指导教师: Tutor: 2013年 02月 25日英文:Thermal comfort in the future Excellence and expectationP. Ole Fanger and Jrn ToftumInternational Centre for Indoor Environment and Energy Technical University of DenmarkAbstractThis paper predicts some trends foreseen in the new century as regards the indoor environment and thermal comfort. One trend discussed is the search for excellence, upgrading present standards that aim merely at an “acceptable condition with a substantial number of dissatisfied. An important element in this connection is individual thermal control。 A second trend is to acknowledge that elevated air temperature and humidity have a strong negative impact on perceived air quality and ventilation requirements. Future thermal comfort and IAQ standards should include these relationships as a basis for design. The PMV model has been validated in the field in buildings with HVAC systems that were situated in cold, temperate and warm climates and were studied during both summer and winter. In non-air-conditioned buildings in warm climates occupants may sense the warmth as being less severe than the PMV predicts, due to low expectations. An extension of the PMV model that includes an expectancy factor is proposed for use in non-air-conditioned buildings in warm climates。 The extended PMV model agrees well with field studies in nonair-conditioned buildings of three continents.Keywords: PMV, Thermal sensation, Individual control, Air quality, AdaptationA Search for ExcellencePresent thermal comfort standards (CEN ISO 7730, ASHRAE 55) acknowledge that there are considerable individual differences between peoples thermal sensation and their discomfort caused by local effects, i.e。 by air movement。 In a collective indoor climate, the standards prescribe a compromise that allows for a significant number of people feeling too warm or too cool. They also allow for air velocities that will be felt as a draught by a substantial percentage of the occupants.In the future this will in many cases be considered as insufficient。 There will be a demand for systems that allow all persons in a space to feel comfortable。 The obvious way to achieve this is to move from the collective climate to the individually controlled local climate。 In offices, individual thermal control of each workplace will be common。 The system should allow for individual control of the general thermal sensation without causing any draught or other local discomfort。A search for excellence involves providing all persons in a space with the means to feel thermally comfortable without compromise.Thermal Comfort and IAQPresent standards treat thermal comfort and indoor air quality separately, indicating that they are independent of each other. Recent research documents that this is not true 。 The air temperature and humidity combined in the enthalpy have a strong impact on perceived air quality, and perceived air quality determines the required ventilation in ventilation standards. Research has shown that dry and cool air is perceived as being fresh and pleasant while the same composition of air at an elevated temperature and humidity is perceived as stale and stuffy。 During inhalation it is the convective and evaporative cooling of the mucous membrane in the nose that is essential for the fresh and pleasant sensation. Warm and humid air is perceived as being stale and stuffy due to the lack of nasal cooling. This may be interpreted as a local warm discomfort in the nasal cavity。 The PMV model is the basis for existing thermal comfort standards. It is quite flexible and allows for the determination of a wide range of air temperatures and humidities that result in thermal neutrality for the body as a whole。 But the inhaled air would be perceived as being very different within this wide range of air temperatures and humidities。 An example: light clothing and an elevated air velocity or cooled ceiling, an air temperature of 28C and a relative humidity of 60 may give PMV=0, but the air quality would be perceived as stale and stuffy。 A simultaneous request for high perceived air quality would require an air temperature of 2022C and a modest air humidity. Moderate air temperature and humidity decrease also SBS symptoms and the ventilation requirement, thus saving energy during the heating season。 And even with airconditioning it may be beneficial and save energy during the cooling season.PMV model and the adaptive modelThe PMV model is based on extensive American and European experiments involving over a thousand subjects exposed to wellcontrolled environments。 The studies showed that the thermal sensation is closely related to the thermal load on the effector mechanisms of the human thermoregulatory system。 The PMV model predicts the thermal sensation as a function of activity, clothing and the four classical thermal environmental parameters. The advantage of this is that it is a flexible tool that includes all the major variables influencing thermal sensation. It quantifies the absolute and relative impact of these six factors and can therefore be used in indoor environments with widely differing HVAC systems as well as for different activities and different clothing habits。 The PMV model has been validated in climate chamber studies in Asia as well as in the field, most recently in ASHRAEs worldwide research in buildings with HVAC systems that were situated in cold, temperate and warm climates and were studied during both summer and winter. The PMV is developed for steadystate conditions but it has been shown to apply with good approximation at the relatively slow fluctuations of the environmental parameters typically occurring indoors。 Immediately after an upward stepwise change of temperature, the PMV model predicts well the thermal sensation, while it takes around 20 min at temperature down-steps 。Field studies in warm climates in buildings without airconditioning have shown, however, that the PMV model predicts a warmer thermal sensation than the occupants actually feel。 For such nonairconditioned buildings an adaptive model has been proposed. This model is a regression equation that relates the neutral temperature indoors to the monthly average temperature outdoors. The only variable is thus the average outdoor temperature, which at its highest may have an indirect impact on the human heat balance. An obvious weakness of the adaptive model is that it does not include human clothing or activity or the four classical thermal parameters that have a wellknown impact on the human heat balance and therefore on the thermal sensation. Although the adaptive model predicts the thermal sensation quite well for nonair-conditioned buildings of the 1900s located in warm parts of the world, the question remains as to how well it would suit buildings of new types in the future where the occupants have a different clothing behaviour and a different activity pattern.Why then does the PMV model seem to overestimate the sensation of warmth in nonairconditioned buildings in warm climates? There is general agreement that physiological acclimatization does not play a role。 One suggested explanation is that openable windows in naturally ventilated buildings should provide a higher level of personal control than in air-conditioned buildings. We do not believe that this is true in warm climates。 Although an openable window sometimes may provide some control of air temperature and air movement, this applies only to the persons who work close to a window。 What happens to persons in the office who work far away from the window? We believe that in warm climates airconditioning with proper thermostatic control in each space provides a better perceived control than openable windows.Another factor suggested as an explanation to the difference is the expectations of the occupants。 We think this is the right factor to explain why the PMV overestimates the thermal sensation of occupants in nonairconditioned buildings in warm climates。 These occupants are typically people who have been living in warm environments indoors and outdoors, maybe even through generations。 They may believe that it is their “destiny” to live in environments where they feel warmer than neutral。 This may be expressed by an expectancy factor, e。 The factor e may vary between 1 and 0.5. It is 1 for air-conditioned buildings。 For nonairconditioned buildings, the expectancy factor is assumed to depend on the duration of the warm weather over the year and whether such buildings can be compared with many others in the region that are air-conditioned。 If the weather is warm all year or most of the year and there are no or few other air-conditioned buildings, e may be 0。5, while it may be 0.7 if there are many other buildings with air-conditioning。 For nonair-conditioned buildings in regions where the weather is warm only during the summer and no or few buildings have air-conditioning, the expectancy factor may be 0。7 to 0。8, while it may be 0。8 to 0.9 where there are many airconditioned buildings. In regions with only brief periods of warm weather during the summer, the expectancy factor may be 0。9 to 1。 Table 1 proposes a first rough estimation of ranges for the expectancy factor corresponding to high, moderate and low degrees of expectation.ExpectationClassification of buildingsExpectancyfactor, eHighNonairconditioned buildings located in regions where air-conditioned buildings are common。 Warm periods occurring briefly during the summer season。0。9 1.0ModerateNon-airconditioned buildings located in regions with some air-conditioned buildings。 Warm summer season.0。7 - 0.9LowNon-airconditioned buildings located in regions with few airconditioned buildings。 Warm weather during all seasons。0.5 - 0。7Table 1。 Expectancy factors for nonair-conditioned buildings in warm climates.A second factor that contributes to the difference between the PMV and actual thermal sensation in nonair-conditioned buildings is the estimated activity。 In many field studies in offices, the metabolic rate is estimated on the basis of a questionnaire identifying the percentage of time the person was sedentary, standing, or walking. This mechanistic approach does not acknowledge the fact that people, when feeling warm, unconsciously tend to slow down their activity. They adapt to the warm environment by decreasing their metabolic rate。 The lower pace in warm environments should be acknowledged by inserting a reduced metabolic rate when calculating the PMV.To examine these hypotheses further, data were downloaded from the database of thermal comfort field experiments. Only quality class II data obtained in nonairconditioned buildings during the summer period in warm climates were used in the analysis. Data from four cities (Bangkok, Brisbane, Athens, and Singapore) were included, representing a total of more than 3200 sets of observations . The data from these four cities with warm climates were also used for the development of the adaptive model.For each set of observations, recorded metabolic rates were reduced by 6。7 for every scale unit of PMV above neutral, i。e. a PMV of 1.5 corresponded to a reduction in the metabolic rate of 10%。 Next, the PMV was recalculated with reduced metabolic rates using ASHRAEs thermal comfort tool 。 The resulting PMV values were then adjusted for expectation by multiplication with expectancy factors estimated to be 0。9 for Brisbane, 0.7 for Athens and Singapore and 0。6 for Bangkok. As an average for each building included in the field studies, Figure 1 and Table 2 compare the observed thermal sensation with predictions using the new extended PMV model for warm climates。Comparison of observed mean thermal sensation with predictions made using the new extension of the PMV model for nonair-conditioned buildings in warm climates。 The lines are based on linear regression analysis weighted according to the number of responses obtained in each building.CityExpectancyfactorPMV adjusted toproper activityPMV adjustedfor expectationObservedmean voteBangkok0.62.01.21.3Singapore0。71.20.80。7Athens0。71。00.70.7Brisbane0。90。90。80。8Table 2. Non-airconditioned buildings in warm climates。 Comparison of observed thermal sensation votes and predictions made using the new extension of the PMV model。The new extension of the PMV model for nonair-conditioned buildings in warm climates predicts the actual votes well. The extension combines the best of the PMV and the adaptive model. It acknowledges the importance of expectations already accounted for by the adaptive model, while maintaining the PMV models classical thermal parameters that have direct impact on the human heat balance. It should also be noted that the new PMV extension predicts a higher upper temperature limit when the expectancy factor is low. People with low expectations are ready to accept a warmer indoor environment。 This agrees well with the observations behind the adaptive model.Further analysis would be useful to refine the extension of the PMV model, and additional studies in non-air-conditioned buildings in warm climates in different parts of the world would be useful to further clarify expectation and acceptability among occupants。 It would also be useful to study the impact of warm office environments on work pace and metabolic rate.ConclusionsThe PMV model has been validated in the field in buildings with HVAC systems, situated in cold, temperate and warm climates and studied during both summer and winter. In non-airconditioned buildings in warm climates, occupants may perceive the warmth as being less severe than the PMV predicts, due to low expectations.An extension of the PMV model that includes an expectancy factor is proposed for use in non-air-conditioned buildings in warm climates。The extended PMV model agrees well with field studies in non-airconditioned buildings in warm climates of three continents。Thermal comfort and air quality in a building should be considered simultaneously. A high perceived air quality requires moderate air temperature and humidity。AcknowledgementFinancial support for this study from the Danish Technical research Council is gratefully acknowledged。ReferencesAndersson, L。O., Frisk, P., Lfstedt, B。, Wyon, D.P。, (1975), Human responses to dry, humidified and intermittently humidified air in large office buildings。 Swedish Building Research Document Series, D11/75.ASHRAE 551992: Thermal environmental conditions for human occupancy. American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc.Baker, N. and Standeven, M. (1995), A Behavioural Approach to Thermal Comfort Assessment in Naturally Ventilated Buildings. Proceedings from CIBSE National Conference, pp 76-84。Brager G。S., de Dear R。J. (1998), Thermal adaptation in the built environment: a literature review。 Energy and Buildings, 27, pp 83-96。Cena, K.M. (1998), Field study of occupant comfort and office thermal environments in a hotarid climate。 (Eds. Cena, K。 and de Dear, R。). Final report, ASHRAE 921RP, ASHRAE Inc。, Atlanta。de Dear, R。, Fountain, M。, Popovic, S。, Watkins, S。, Brager, G。, Arens, E。, Benton, C., (1993a), A field study of occupant comfort and office thermal environments in a hot humid climate. Final report, ASHRAE 702 RP, ASHRAE Inc., Atlanta。de Dear, R., Ring, J。W。, Fanger, P.O. (1993b), Thermal sensations resulting from sudden ambient temperature changes。 Indoor Air, 3, pp 181-192.de Dear, R。 J., Leow, K. G. and Foo, S.C。 (1991), Thermal comfort in the humid tropics: Field experiments in airconditioned and naturally ventilated buildings in Singapore. International Journal of Biometeorology, vol. 34, pp 259265.de Dear, R。J。 (1998), A global database of thermal comfort field experiments. ASHRAE Transactions, 104(1b), pp 11411152.de Dear, R。J. and Auliciems, A。 (1985), Validation of the Predicted Mean Vote model of thermal comfort in six Australian field studies。 ASHRAE Transactions, 91(2), pp 452- 468.de Dear, R。J., Brager G.S。 (1998), Developing an adaptive model of thermal comfort and preference。 ASHRAE Transactions, 104(1a), pp 145-167。de Dear, R。J., Leow, K.G。, and Ameen, A。 (1991), Thermal comfort in the humid tropics - Part I: Climate chamber experiments on temperature preferences in Singapore。 ASHRAE Transactions 97(1), pp 874-879。Donini, G。, Molina, J., Martello, C., Ho Ching Lai, D。, Ho Lai, K., Yu Chang, C., La Flamme, M., Nguyen, V。H。, Haghihat, F。 (1996), Field study of occupant comfort and office thermal environments in a cold climate. Final report, ASHRAE 821 RP, ASHRAE Inc。, Atlanta.Fang, L., Clausen, G., Fanger, P.O。 (1999), Impact of temperature and humidity on chemical and sensory emissions from building materials. Indoor Air, 9, pp 193201.Fanger, P。O。 (1970), Thermal comfort。 Danish Technical Press, Copenhagen, Denmark.Fouintain, M。E. and Huizenga, C。 (1997), A thermal sensation prediction tool for use by the profession。 ASHRAE Transactions, 103(2), pp 130-136.Humphreys, M.A。 (1978), Outdoor temperatures and comfort indoors。 Building Research and Practice, 6(2), pp 92105。Krogstad, A.L。, Swanbeck, G。, Barregrd, L。, et al. (1991), Besvr vid kontorsarbete med olika temperaturer i arbetslokalen en prospektiv underskning (A prospective study of indoor climate problems at different temperatures in offices), Volvo Truck Corp。, Gteborg, Sweden。Tanabe, S。, Kimura, K., Hara, T. (1987), Thermal comfort requirements during the summer season in Japan. ASHRAE Transactions, 93(1), pp 564-577。Toftum, J., Jrgensen, A。S。, Fanger, P。O。 (1998), Upper limits for air humidity for preventing warm respiratory discomfort. Energy and Buildings, 28(3), pp 15-23。中文:未来的热舒适性-优越性和期望值Fanger和Jrn Toftum国际室内环境中心和丹麦能源科技大学摘要本文预测了一些在新世纪中可以预见的热舒适性以及室内环境的发展趋势。讨论了探究优越性的一种趋势,提升现在只为达到一个“可接受”的条件且又有许多令人不满意的标准。在这一点上独立的热控制是一个要素。第二种趋势是承认空气温度和湿度的上升对感知到的空气质量和通风要求有着很大的负面影响.作为设计的基础,未来热舒适性和室内空气品质的标准应该包括这些关系.预测平均评价模型已经在处于寒冷、温暖以及炎热的气候条件下配备暖通空调系统的建筑中得到验证,而且研究贯穿了夏季和冬季.处于炎热气候条件下非空调建筑内的居住者由于他们较低的期望值,感受到的温度可能不像预测平均评价中预测的那么高。涵盖了期望因素的预测平均评价拓展模型被提议在炎热气候条件下非空调建筑中运用.预测平均评价拓展模型与在三大洲的非空调建筑中的实地研究十分匹配。关键词:预测平均评价模型,热感受,单独控制,空气品质,适应性一项追求优越性的研究目前的热舒适性标准(欧洲标准化委员会 ISO 7730, 美国采暖、制冷与空调工程师学会 55)承认人们的热感受和他们由于局部作用(也就是空气流动)产生的不舒适感之间存在着相当大的个体差异.在一个集体性的室内气候中,这些标准考虑到相当多的人感觉太热或太冷,做了一个折衷。这些标准也考虑到了大多数居住者因为空气流动而感受到吹风感.未来,在很多情况下这将被认为是不足的。将会有一种让空间内所有的人都感觉舒适的系统需求。实现这种需求最显著的方式是从整体气候转移到独立控制的局部气候中去.在办公室中,对每个工作场所的独立热控制将会得到普及。这个系统应该考虑到整体热感觉的单独控制而不会引起任何吹风感或着其他局部不舒适的感觉。这项追求优越性的研究涉及到为空间内的所有人提供热舒适感,而不是让他们妥协。热舒适性与室内空气品质现有的标准将热舒适性和室内空气品质区别对待,这表明它们是相互独立的。最近的研究认为这是不正确的。由空气的温度和湿度决定的焓值对可感知的空气品质有着很大的影响,在通风标准中可感知的空气品质决定了必要的通风量。研究已经表明干燥、凉爽的空气让人觉得清新和舒适,但是将相同成分空气的温度和湿度提高却让人觉得不新鲜和闷热。吸入空气是对鼻粘膜的对流和蒸发冷却,鼻粘膜对于新鲜和愉悦感是必不可少的。由于缺少鼻黏膜的冷却,炎热、潮湿的空气被认为是不新鲜和闷热的。这可以理解为鼻腔的局部热不舒适感。预测平均评价模型是目前热舒适性标准的基础。总的来说,它是相当灵活的,并且考虑到了对空气温湿度大范围的测定导致的人体热中性。但是,在这个大范围的空气温湿度中,吸入的空气会被看成是十分不同的。举个例子:轻薄的衣服,提高空气流速,冷却的顶棚和空气温度为28,相对湿度为60,预测平均评价将为0。除此之外,空气的品质也会被认为是不新鲜和闷热的。高品质的空气需要气温在2022之间,而且空气的湿度适中。适中的空气温度和湿度减少了病态建筑综合症和通风需求,因此在供暖季节中节约了能源.它甚至可能对空调有益,空调季节节能。预测平均评价模型和适应性模型预测平均评价模型建立在大量的美国和欧洲实验的基础上,涉及到超过1000名处于良好受控环境中的被测试者.研究表明热感觉与作用于人体体温调节系统效应机理上的热负荷有着紧密的联系。预测平均评价模型根据活动、衣服以及四个经典热环境参数来预测热感受。
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 生活休闲 > 励志创业


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!