资源描述
La4A1010La4A1011La4A1012La4A2013La4A2014La4A2015La4A2016La4A2017La4A2018La4A2019La4A3020La4A2021La4A2022La4A3023La4A4024La4A5025La4A5026La4A4027La4A4028La4A1029Lb4A1068Lb4A1069Lb4A2070Lb4A2071Lb4A3072Lb4A3073Lb4A3074Lb4A3075Lb4A3076Lb4A3077Lb4A3078Lb4A4079Lb4A4080Lb4A4081Lb4A4082Lb4A4083Lb4A5084Jc4A1133Jc4A1134Lc4A3135Lc4A3136Jd4A1158Jd4A2159Jd4A3160Jd4A2161Jd4A2162Jd4A2163Jd4A2164Jd4A3165Jd4A4166Jd4A3167Jd4A3168Jd4A3169Jd4A3170Jd4A3171Jd4A4172Je4A1226Je4A3227Je4A4228Je4A4229Je4A4230Je4A4231Je4A4232Je4A4233Je4A4234Je4A4235Je4A3236Je4A3237Je4A4238Je4A4239Je4A3240Je4A3241Je4A2242Je4A2243Je4A3244Je4A3245Je4A3246Je4A3247Je4A4248Je4A4249Je4A4250Je4A4251Je4A4252Je4A4253Je4A4254Je4A4255Je4A2256Je4A4257Je4A4258Je4A4259Je4A2260Je4A2261Je4A2262Je4A4263Je4A3264Je4A3265Je4A2266Jf4A3322Jf4A3323Jf4A3324Jf4A4325Jf4A3326Jd4A2327Jf4A3328Jf4A3329Jf4A2330Jf4A2331将将一一根根电电阻阻等等于于R R的的均均匀匀导导线线,对对折折起起来来并并联联使使用用时时,则则电电阻阻变变为为(A)A)。A.A.R/4R/4;B.R/2B.R/2;C.RC.R;D.2RD.2R。阻阻值值分分别别为为R R和和1R1R的的两两只只电电阻阻串串联联后后接接入入电电路路,则则阻阻值值小小的的电电阻阻发发热热量量是是阻阻值值大大的的电电阻阻发发热热量量的的(B)B)倍倍。A.A.1 1;B.B.1/21/2;C.2C.2;D.D.1/31/3。阻阻值值分分别别为为R R和和2R2R的的两两只只电电阻阻并并联联后后接接入入电电路路,则则阻阻值值小小的的电电阻阻发发热热量量是是阻阻值值大大的的电电阻阻发发热热量量的的(A)A)倍倍。A.2A.2;B.4B.4;C.1/2C.1/2;D.1/3D.1/3。三三个个阻阻值值相相等等的的电电阻阻串串联联时时的的总总电电阻阻是是并并联联时时总总电电阻阻的的(B)B)。A.6A.6倍倍;B.9B.9倍倍;C.3C.3倍倍;D.12D.12倍倍。导导体体切切割割磁磁力力线线时时,其其产产生生感感应应电电动动势势的的大大小小与与磁磁场场的的磁磁感感应应强强度度(B)B)。A.A.的的平平方方成成正正比比;B.B.的的一一次次方方成成正正比比;C.C.的的大大小小无无关关;D.D.成成反反比比。载载流流导导体体在在磁磁场场中中所所受受力力的的大大小小与与导导体体有有效效长长度度(C)C)。A.A.的的1/21/2成成正正比比;B.B.无无关关;C.C.成成正正比比;D.D.成成反反比比。三三相相对对称称负负载载星星形形连连接接时时,其其线线电电流流为为相相电电流流的的(B)B)倍倍。A.3A.3;B.1B.1;C.1/2C.1/2;D.1D.1/3/3。磁磁阻阻的的大大小小与与磁磁路路的的长长度度(C C)。A.A.无无关关;B.B.成成反反比比;C.C.成成正正比比;D.D.成成非非线线性性关关系系。由由铁铁磁磁材材料料构构成成的的磁磁通通集集中中通通过过的的路路径径,称称为为(C)(C)。A.A.电电路路;B.B.磁磁链链;C.C.磁磁路路;D.D.磁磁场场。已已知知R=3,XR=3,XL L=15,X=15,Xc c=ll,=ll,将将它它们们串串联联时时,总总阻阻抗抗Z Z等等于于(C)C)。A.29A.29;B.7B.7;C.5C.5;D.3D.30 0表表示示正正弦弦电电路路中中电电容容电电流流的的计计算算式式是是(B B)。A.A.i=u/Xci=u/Xc;B.B.I=UI=UC,C,C.i=u/C.i=u/C C;D.I=D.I=U/CU/C。正正弦弦电电路路中中电电容容元元件件的的无无功功功功率率表表达达式式是是(A)(A)。A.A.Qc=UQc=U2 2CC;B.B.Qc=IQc=I2 2CC;C C.Q.Qc c=X=Xc ci i2 2;D.D.QcQc=U=U2 2/C/C。表表示示正正弦弦电电路路电电感感电电流流的的下下列列计计算算式式中中,正正确确的的是是(B)B)。A.i=u/XA.i=u/XL L;B.I=U/B.I=U/LL;C.I=ULC.I=UL;D.I=UXD.I=UXL L。电电磁磁感感应应过过程程中中,回回路路中中所所产产生生的的电电动动势势是是由由(B)(B)决决定定的的。A.A.通通过过回回路路的的磁磁通通量量;B.B.回回路路中中磁磁通通量量变变化化率率;C.C.回回路路所所包包围围的的面面积积;D.D.回回路路边边长长。某某工工频频正正弦弦电电流流,当当t t=0=0,i i(0)(0)=5A=5A为为最最大大值值,则则该该电电流流解解析析式式是是(C)C)。A.i=52sin(100A.i=52sin(100tt-90)-90);B.i=52sin(100t+90)B.i=52sin(100t+90);C.i=5sin(100t+90)C.i=5sin(100t+90);D.i=5sin(100t)D.i=5sin(100t)。通通电电导导体体在在磁磁场场中中所所受受的的力力是是(C C)。A.A.电电场场力力;B.B.磁磁场场力力;C.C.电电磁磁力力;D.D.引引力力。自自感感系系数数L L与与(D)D)有有关关。A.A.电电流流大大小小;B.B.电电压压高高低低;C.C.电电流流变变化化率率;D D.线线圈圈结结构构及及材材料料性性质质。已已知知某某元元件件的的u u=100=10022sin(sin(tt+30+30)V,i=1002sin(t-60)A,V,i=1002sin(t-60)A,则则该该元元件件为为(B)B)。A.A.电电阻阻;B.B.电电感感;C.C.电电容容;D.D.无无法法确确定定。已已知知R R、L L、C C串串联联电电路路中中,电电流流I I滞滞后后端端电电压压U U,则则下下面面结结论论中中,正正确确的的是是(B)B)。A.XA.XC CXXL L B.XB.Xc cX0,u0,du/dt0du/dt0时时,则则表表明明电电容容器器正正在在(B)B)。B.B.充充电电;非非正正弦弦交交流流电电的的有有效效值值等等于于(B B)。B.B.各各次次谐谐波波有有效效值值平平方方和和的的平平方方根根晶晶体体管管符符号号中中,箭箭头头朝朝外外者者,表表示示它它是是(C)。C.NPN管管晶晶体体管管符符号号中中,箭箭头头朝朝内内者者,表表示示它它是是(D)。D.PNP管管。电电工工仪仪表表的的准准确确度度等等级级以以仪仪表表最最大大(C)误误差差来来表表示示。C.引引用用单单相相半半波波整整流流电电路路中中流流过过二二极极管管的的正正向向电电流流的的平平均均值值与与流流过过负负载载的的电电流流平平均均值值的的关关系系为为(A)。A.两两者者相相等等磁磁电电式式微微安安表表使使用用后后应应将将其其两两个个接接线线端端子子(D)。D.用用导导线线短短接接。某某变变压压器器的的一一、二二次次绕绕组组匝匝数数之之比比等等于于25。二二次次侧侧额额定定电电压压是是400V,则则一一次次侧侧额额定定电电压压是是(A)。A.10000V;普普通通万万用用表表的的交交流流挡挡,测测量量机机构构反反映映的的是是(B)。B.平平均均值值,定定度度是是按按正正弦弦波波的的有有效效值值;。高高压压绝绝缘缘试试验验中中,要要求求直直流流试试验验电电压压在在输输出出工工作作电电流流下下,其其电电压压的的脉脉动动因因数数应应不不大大于于(B)。B.3%;直直流流试试验验电电压压值值指指的的是是直直流流电电压压的的(A)。A.算算术术平平均均值值;B.最最大大值值;C.最最小小值值;D.峰峰值值。运运行行中中的的变变压压器器铁铁心心允允许许(A)。A.一一点点接接地地;B.两两点点接接地地;C.多多点点接接地地;D.不不接接地地。测测量量大大电电容容量量的的设设备备绝绝缘缘电电阻阻时时,测测量量完完毕毕后后为为防防止止电电容容电电流流反反充充电电损损坏坏绝绝缘缘电电阻阻表表,应应(A)。A.先先断断开开绝绝缘缘电电阻阻表表与与设设备备的的连连接接,再再停停止止绝绝缘缘电电阻阻表表;B.先先停停止止绝绝缘缘电电阻阻表表,再再断断开开绝绝缘缘电电阻阻表表与与设设备备的的连连接接;C.断断开开绝绝缘缘电电阻阻表表与与设设备备的的连连接接和和停停止止绝绝缘缘电电阻阻表表同同时时操操作作;D.先先对对设设备备进进行行放放电电,再再进进行行其其他他操操作作。试试品品绝绝缘缘表表面面脏脏污污、受受潮潮,在在试试验验电电压压下下产产生生表表面面泄泄漏漏电电流流,对对试试品品tan和和C测测量量结结果果的的影影响响程程度度是是(C)。A.试试品品电电容容量量越越大大,影影响响越越大大;B.试试品品电电容容量量越越小小,影影响响越越小小;C.试试品品电电容容量量越越小小,影影响响越越大大;D.与与试试品品电电容容量量的的大大小小无无关关。三三相相变变压压器器的的三三相相磁磁路路不不对对称称,正正常常情情况况下下,三三相相空空载载励励磁磁电电流流不不相相等等,三三相相心心柱柱中中的的磁磁通通量量为为(C)。A.两两边边相相相相等等,并并大大于于中中间间相相;B.两两边边相相相相等等,并并小小于于中中间间相相;C.三三相相相相等等;D.三三相相不不相相等等,且且无无规规律律。经经耐耐受受105的的液液体体介介质质浸浸渍渍过过的的纸纸、纸纸板板、棉棉纱纱等等都都属属于于(A)绝绝缘缘。A.A 级级;B.B 级级;C.Y 级级;D.F 级级。电电动动机机的的额额定定功功率率是是指指在在额额定定运运行行状状态态下下(C)。A.从从电电源源输输入入的的电电功功率率;B.电电动动机机的的发发热热功功率率;C.电电动动机机轴轴输输出出的的机机械械功功率率;D.电电动动机机所所消消耗耗的的功功率率。电电动动机机铭铭牌牌上上的的温温升升是是指指(D)。A.电电动动机机工工作作的的环环境境温温度度;B.电电动动机机的的最最髙髙工工作作温温度度;C.电电动动机机的的最最低低工工作作温温度度;D.电电动动机机绕绕组组最最高高允允许许温温度度和和环环境境温温度度之之差差值值。异异步步电电动动机机转转子子的的转转速速与与旋旋转转磁磁场场的的关关系系是是(A)(A)。A.转转子子转转速速小小于于磁磁场场转转速速;B.转转子子转转速速大大于于磁磁场场转转速速;C.转转子子转转速速等等于于磁磁场场转转速速;D.转转子子转转速速与与磁磁场场转转速速无无关关。控控制制三三相相异异步步电电动动机机正正、反反转转是是通通过过改改变变(D)实实现现的的。A.电电流流大大小小;B.电电流流方方向向;C.电电动动机机结结构构;D.电电源源相相序序。对对GIS进进行行耐耐压压试试验验,不不允允许许使使用用(D)。D.直直流流电电压压。额额定定电电压压为为110kV及及以以下下的的油油浸浸式式变变压压器器,电电抗抗器器及及消消弧弧线线圈圈应应在在充充满满合合格格油油,静静置置一一定定时时间间后后,方方可可进进行行耐耐压压试试验验。其其静静置置时时间间如如无无制制造造厂厂规规定定,则则应应是是(C)。C.24h;若若设设备备组组件件之之一一的的绝绝缘缘试试验验值值为为tan1=5%,C1=250pF;而而设设备备其其余余部部分分绝绝缘缘试试验验值值为为tan2=0.4%,C2=10000pF,则则设设备备整整体体绝绝缘缘试试验验时时,其其总总的的tan值值与与(B)接接近近。B.0.5%;R、L、C串串联联电电路路处处于于谐谐振振状状态态时时,电电容容C两两端端的的电电压压等等于于(A)。A.电电源源电电压压与与电电路路品品质质因因数数Q的的乘乘积积;R、L、C并并联联电电路路处处于于谐谐振振状状态态时时,电电容容C两两端端的的电电压压等等于于(D)。D.电电源源电电压压。正正弦弦交交流流电电路路发发生生串串联联谐谐振振时时,电电路路中中的的电电流流与与电电源源电电压压间间的的相相位位关关系系是是(A)。A.同同相相位位正正弦弦交交流流电电路路发发生生并并联联谐谐振振时时,电电路路的的总总电电流流与与电电源源电电压压间间的的相相位位关关系系是是(B)。B.同同相相位位TYD220/3电电容容式式电电压压互互感感器器,其其额额定定开开路路的的中中间间电电压压为为13kV,若若运运行行中中发发生生中中间间变变压压器器的的短短路路故故障障,则则主主电电容容C1承承受受的的电电压压将将提提高高约约(B)。B.10%;发发电电机机的的调调整整特特性性曲曲线线是是指指在在保保持持转转速速、负负载载功功率率因因数数和和端端电电压压不不变变的的条条件件下下(C)的的关关系系曲曲线线。C.转转子子电电流流和和定定子子电电流流对对330kV及及以以下下变变压压器器的的油油中中溶溶解解气气体体分分析析,发发现现乙乙炔炔含含量量超超过过(B)体体积积分分数数时时,应应引引起起注注意意。B.510-6;当当球球间间距距不不大大于于球球半半径径时时,常常用用的的测测量量球球隙隙是是典典型型的的(B)电电场场间间隙隙。B.稍稍不不均均匀匀;表表征征SF6气气体体理理化化特特性性的的下下列列各各项项中中,(C)项项是是错错的的。C.可可燃燃变变压压器器空空载载试试验验中中,额额定定空空载载损损耗耗P0及及空空载载电电流流I0计计算算值值和和变变压压器器额额定定电电压压UN与与试试验验施施加加电电压压U0比比值值(UN/U0)之之间间的的关关系系,在在下下述述各各项项描描述述中中,(D)项项最最准准确确(其其中中,U0的的取取值值范范围围在在0.11.05倍倍UN之之间间)。A.P0、I0与与(UN/U0)成成正正比比;B.P0与与(UN/U0)成成正正比比;I0与与(UN/U0)成成正正比比;C.P0与与(UN/U0)n成成比比例例;I0与与(UN/U0)m成成比比例例,而而n=1.92.0;m=12;D.当当(UN/U0)=1.0时时,P0及及I0的的计计算算值值等等于于试试验验测测得得值值。在在变变压压器器负负载载损损耗耗和和空空载载损损耗耗测测量量的的参参数数中中,(C)项项参参数数受受试试验验电电源源频频率率的的影影响响可可忽忽略略不不计计。C.绕绕组组电电阻阻损损耗耗和和短短路路阻阻抗抗的的电电阻阻分分量量;高高压压断断路路器器断断口口并并联联电电容容器器的的作作用用是是(B)。B.均均压压测测量量发发电电机机转转子子绕绕组组绝绝缘缘电电阻阻时时,绝绝缘缘电电阻阻表表“L”端端子子引引线线接接于于转转子子滑滑环环上上,“E”端端子子引引线线接接于于(A)。A.转转子子轴轴上上采采用用单单相相电电源源自自低低压压侧侧加加压压,对对YNd11三三相相变变压压器器进进行行空空载载试试验验时时,由由于于磁磁路路不不对对称称,正正常常情情况况下下,三三相相之之间间各各相相空空载载损损耗耗大大小小的的关关系系是是(C)。C.Pca/(1.31.5)=Pab=Pbc;c。变变压压器器绝绝缘缘普普遍遍受受潮潮以以后后,绕绕组组绝绝缘缘电电阻阻、吸吸收收比比和和极极化化指指数数(A)。A.均均变变小小有有n个个试试品品并并联联在在一一起起测测量量直直流流泄泄漏漏电电流流,测测得得值值为为I,则则流流过过每每个个试试品品的的泄泄漏漏电电流流必必(A)。A.A.不不大大于于I;I;试试品品电电容容量量约约15000pF,使使用用西西林林电电桥桥,施施加加10kV测测量量其其tan时时,电电桥桥分分流流器器位位置置宜宜选选定定在在(C)挡挡位位置置。C.0.06;用用额额定定电电压压10kV的的试试验验变变压压器器,测测量量电电容容量量为为20000pF试试品品的的tan时时,在在下下列列试试验验变变压压器器容容量量中中最最小小可可选选择择(B)kVA。B.1.0;有有n个个试试品品的的介介质质损损耗耗因因数数分分别别为为tan1、tan2、tan3、tann,若若将将它它们们并并联联在在一一起起测测得得的的总总tan值值必必为为tan1、tann中中的的(D)。A.最最大大值值;B.最最小小值值;C.平平均均值值;D.某某介介于于最最大大值值与与最最小小值值之之间间的的值值。交交流流耐耐压压试试验验会会对对某某些些设设备备绝绝缘缘形形成成破破坏坏性性的的积积累累效效应应,而而在在下下列列各各类类设设备备中中,(C)却却几几乎乎没没有有积积累累效效应应。A.变变压压器器和和互互感感器器;B.电电力力电电容容器器和和电电力力电电缆缆;C.纯纯瓷瓷的的套套管管和和绝绝缘缘子子;D.发发电电机机和和调调相相机机。电电容容分分压压器器的的主主电电容容为为C1,分分压压电电容容为为C2,则则电电容容分分压压器器的的分分压压比比K=U1/U2=(A)。A.(C1+C2)/C1;B.(C1+C2)/C2;C.C1/(C1+C2);D.C2/(C1+C2)。对对电电容容型型绝绝缘缘结结构构的的电电流流互互感感器器进进行行(D)时时,不不可可能能发发现现绝绝缘缘末末屏屏引引线线在在内内部部发发生生的的断断线线或或不不稳稳定定接接地地缺缺陷陷。D.次次绕绕组组直直流流电电阻阻测测量量及及变变比比检检查查试试验验。下下列列各各种种因因素素中中,(C)与与变变压压器器高高压压绕绕组组直直流流电电阻阻的的测测得得值值无无关关。C.高高压压绕绕组组主主绝绝缘缘的的tan值值,直直流流泄泄漏漏电电流流和和绝绝缘缘电电阻阻值值超超标标;用用倒倒相相法法消消除除外外电电场场对对tan测测量量的的干干扰扰,需需先先在在试试验验电电源源正正、反反相相两两种种极极性性下下,测测得得两两组组数数据据:C1 1、tan1和和C2、tan2,然然后后按按公公式式(C)计计算算出出试试品品的的实实际际tan。C.tan=(C1tan1+C2tan2)/(C1+C2);交交流流无无间间隙隙金金属属氧氧化化物物避避雷雷器器的的额额定定电电压压是是指指(C)。A.其其安安装装地地点点的的电电网网额额定定相相电电压压;B.其其安安装装地地点点的的电电网网额额定定线线电电压压;C.施施加加到到避避雷雷器器端端子子间间的的最最大大允允许许工工频频电电压压有有效效值值,它它表表明明避避雷雷器器能能在在按按规规定定确确定定的的暂暂时时过过电电压压下下正正确确地地工工作作,但但它它不不等等于于电电网网的的额额定定电电压压;D.允允许许持持久久地地施施加加在在避避雷雷器器端端子子间间的的工工频频电电压压有有效效值值。交交流流无无间间隙隙金金属属氧氧化化物物避避雷雷器器在在通通过过直直流流1mA参参考考电电流流吋吋,测测得得的的避避雷雷器器端端子子间间的的直直流流电电压压平平均均值值称称为为该该避避雷雷器器的的(A)。A.直直流流1mA参参考考电电压压;B.工工频频参参考考电电压压;C.额额定定电电压压;D.持持续续运运行行电电压压。允允许许持持久久地地施施加加在在交交流流无无间间隙隙金金属属氧氧化化物物避避雷雷器器端端子子间间的的工工频频电电压压有有效效值值称称为为该该避避雷雷器器的的(B)。A.额额定定电电压压;B.持持续续运运行行电电压压;C.工工频频参参考考电电压压;D.允允许许运运行行电电压压。下下列列介介质质中中,(A)是是亲亲水水性性物物质质。A.电电瓷瓷;B.聚聚乙乙烯烯;C.石石蜡蜡;D.绝绝缘缘纸纸。四四只只灯灯泡泡分分别别与与R、C、L及及RLC串串联联后后,组组成成四四条条支支路路再再并并联联接接入入电电源源。当当电电源源频频率率增增加加时时,与与(B)串串联联的的灯灯泡泡亮亮度度增增大大。A.R;B.C;C.L;D.R、L、C。绝绝缘缘油油在在电电弧弧作作用用下下产产生生的的气气体体大大部部分分是是(B)。B.氢氢、乙乙炔炔;变变压压器器进进水水受受潮潮时时,油油中中溶溶解解气气体体色色谱谱分分析析含含量量偏偏高高的的气气体体组组分分是是(C)。C.氢氢气气;下下述述变变压压器器绝绝缘缘预预防防性性试试验验项项目目,对对发发现现绕绕组组绝绝缘缘进进水水受受潮潮均均有有一一定定作作用用,而而较较为为灵灵敏敏、及及时时、有有效效的的是是(D)。D.测测定定油油中中微微量量水水分分。35kV及及以以上上少少油油断断路路器器直直流流泄泄漏漏电电流流一一般般要要求求不不大大于于(B)A。B.10无无间间隙隙金金属属氧氧化化物物避避雷雷器器在在75%直直流流1mA参参考考电电压压下下的的泄泄漏漏电电流流应应不不大大于于(C)A。C.50电电力力设设备备的的接接地地电电阻阻试试验验周周期期是是不不超超过过(D)年年。D.6。电电气气设设备备外外绝绝缘缘形形成成的的电电容容,在在高高电电压压作作用用下下的的能能量量损损耗耗是是(D)。D.介介质质损损耗耗。直直流流单单臂臂电电桥桥主主要要用用来来测测量量(A)左左右右的的中中值值电电阻阻。A.110M;用用QJ23型型直直流流单单臂臂电电桥桥测测量量500的的电电阻阻时时,电电桥桥比比例例臂臂应应选选择择在在(C)挡挡位位置置。C.0.1;测测量量电电动动机机励励磁磁回回路路的的整整流流电电流流时时,应应选选用用(A)式式仪仪表表。A.磁磁电电稳稳压压管管在在稳稳定定范范围围内内允允许许流流过过管管子子的的最最大大电电流流称称为为稳稳压压管管的的(C)电电流流。C.最最大大稳稳定定;晶晶体体管管电电路路中中,若若用用RC移移相相网网络络倒倒相相180,则则至至少少要要用用(C)RC移移相相网网络络。C.三三节节;绕绕组组绝绝缘缘耐耐热热等等级级为为B级级的的电电机机,运运行行时时,绕绕组组绝绝缘缘最最热热点点温温度度不不得得超超过过(D)。D.130C。高高频频阻阻波波器器的的作作用用是是(C)。C.阻阻止止高高频频电电流流向向变变电电站站母母线线分分流流;零零序序电电流流保保护护灵灵敏敏度度高高,动动作作时时间间短短,所所以以(B)。A.在在电电力力系系统统得得到到广广泛泛应应用用;B.在在110kV及及以以上上中中性性点点直直接接接接地地系系统统中中得得到到广广泛泛应应用用;C.在在系系统统运运行行中中起起主主导导作作用用;D.电电力力系系统统不不太太适适用用。变变压压器器绕绕组组匝匝间间绝绝缘缘属属于于(B)。B.纵纵绝绝缘缘;。一一个个10V的的直直流流电电压压表表表表头头内内阻阻10k,若若要要将将其其改改成成250V的的电电压压表表,所所需需串串联联的的电电阻阻应应为为(B)。B.240k;在在铸铸铁铁工工件件上上攻攻M10螺螺纹纹,需需钻钻底底孔孔直直径径为为(C)mm。C.8.9;用用游游标标卡卡尺尺(A)测测出出工工件件尺尺寸寸。A.可可直直接接;B.可可间间接接;C.并并通通过过计计算算可可;D.不不能能。内内径径千千分分尺尺用用来来测测量量工工件件的的(D)尺尺寸寸。D.内内径径和和槽槽宽宽。La4B1018La4B1019La4B2020La4B2021La4B2022La4B2023La4B3024La4B3025La4B3026La4B3027La4B3028La4B3029La4B3030Lb4B3031La4B3032Lb4B2076Lb4B2077Lb4B2078Lb4B3079Lb4B3080Lb4B3081Lb4B3082Lb4B3083Lb4B3084Lb4B3085Lb4B3086Lb4B3087Lb4B3088Lb4B4089Lb4B4090Lb4B4091Lb4B4092Lb4B5093Lb4B5094Lb4B5095Lc4B3132Lc4B4133Lc4B5134Lc4B2135Lc4B5136Jd4B1196Jd4B1197Jd4B2198Jd4B2199Jd4B2200Jd4B3201Jd4B3202Jd4B3203Jd4B3204Jd4B4205Jd4B3206Jd4B4207Jd4B3208Jd4B3209Jd4B3210Jd4B3211Jd4B3212Jd4B3213Jd4B5214Je4B3291Je4B3292Je4B3293Je4B3294Je4B3295Je4B3296Je4B3297Je4B3298Je4B4299Je4B4300Je4B3301Je4B4302Je4B3303Je4B5304Je4B4305Je4B3306Je4B3307Je4B4308Je4B4309Je4B3310Je4B5311Je4B4312Je4B4313Je4B3314Je4B3315Je4B4316Je4B5317Je4B3318Je4B3319Je4B3320Je4B3321Je4B3322Je4B3323Jf4B3369Jf4B3370Jf4B4371Jf4B4372正弦交流电的三要素是最大值、初相位、角频率。(V)正弦交流电的有效值等于3倍最大值。(X)容抗随频率的升髙而增大,感抗随频率的下降而增大。(X)几个电阻串联后的总电阻等于各串联电阻的总和。(V)几个电阻并联后的总电阻等于各并联电阻的倒数和。(X)描述磁场的磁力线,是一组既不中断又互不相交,却各自闭合,既无起点又无终点的回线。(V)在纯电阻负载的正弦交流电路中,电阻消耗的功率总是正值,通常用平均功率表示,平均功率的大小等于瞬时功率最大值的一半。(V)交流电的频率越高,则电容器的容抗越大;电抗器的感抗越小。(X)容性无功功率与感性无功功率两者的表达形式相同,性质也相同。(X)在交流电压下,两种不同介电系数的绝缘介质串联使用时,介电系数小的介质上承受的电压高。(V)介质的绝缘电阻随温度升高而减少,金属材料的电阻随温度升高而增加。(V)在边长为1cm的正方体电介质两对面上量得的电阻值,称为该电介质的表面电阻率。(X)基尔霍夫第二定律(电压定律)指明的是:电路中,沿任一回路循一个方向,在任一时刻其各段的电压代数和恒等于零。(V)在串联电路中,流过各串联元件的电流相等,各元件上的电压则与各自的阻抗成正比。(V)通过一个线圈的电流越大,产生的磁场越强,穿过线圈的磁力线也越多。(V)大气过电压可分为直接雷击、雷电反击和感应雷电过电压。(V)气体间隙的击穿电压与多种因素有关,但当间隙距离一定时,击穿电压与电场分布、电压种类及棒电极极性无关。(X)良好的设备绝缘其泄漏电流与外施直流电压的关系是近似的线性关系。(V)正弦电压 u=141.4sin(t-30)的相量为 141.4/-30。(X)在交流或冲击电压作用下,各层绝缘所承受的电压大小与各层绝缘的电容成反比,即各绝缘层中的电场强度是和各层绝缘材料的介电常数成反比的。(V)橡塑绝缘类电力电缆,不包含交联聚乙烯绝缘电力电缆。(X)有电感L或电容C构成的电路中,从一个稳定状态换到另一个稳定状态,总是要产生过渡过程的。(V)串联谐振的特点是:电路总电流达到最小值,电路总阻抗达到最大值,在理想情况下(R=0),总电流可达到零。(X)并联谐振的特点是:电路的总阻抗最小,即Z=R,电路中电流最大,在电感和电容上可能出现比电源电压高得多的电压。(X)周部放电起始电压是指试验电压从不产生局部放电的较低电压逐渐增加至观测的局部放电量大于某一规定值时的最低电压。(V)根据直流泄漏电流测量值及其施加的直流试验电压值,可以换算出试品的绝缘电阻值。(V)电容C通过电阻R放电的时间常数t=RC。(V)当有机绝缘材料由中性分子构成时,不存在偶极子极化,这类材料主要是电导损耗,其tan小。(V)由于静电感应使导体出现感应电荷。感应电荷分布在导体的表面,其分布情况取决于导体表面的形状,导体表面弯曲度愈大的地方,聚集的电荷愈多;较平坦的地方聚集的电荷就少。导体尖端由于电荷密集,电场强度很强,故容易形成“尖端放电”现象。(V)若某交流电波形的波形因数不等于1.11、波顶因数不等于1.414时,则该交流电为非正弦交流电。(V)R、L、C并联电路在谐振频率附近呈现高的阻抗值,因此当电流一定时,电路两端将呈现高电压。(X)在R、L、C串联电路中,当发生串联谐振时,电路呈现出纯电阻性质,也就是说电路中的感抗和容抗都等于零。(X)交流电桥平衡的条件是两组对边桥臂阻抗绝对值的乘积相等。(X)某部分电路的端电压瞬时值为u,电流的瞬时值为I;并且两者有一致的正方向时,其瞬时功率p=ui,则当p0时,表示该电路向外部电路送出能量;pXL,即XC2XL时,击穿后电流增大;当XC-XLXL,即XCXL,因此击穿后电流增大,电流表指示上升,但有时因试品电容量很大或试验变压器漏抗很大时,也可能出现XC2XL的情况,这时电流表指示就会不变或下降,这种情况属非正常的,除非有特殊必要(例如用串联谐振法进行耐压试验)一般应避免。对有载调压开关应做哪些试验?带电前应做哪些检査调试?答:有载调压开关,应进行以下电气试验:(1)拍摄开关切换过程的录波图,检查切换是否完好,符合规定程序。(2)检查过渡电阻的阻值,偏差一般不应超出设计值的10%。(3)检查每一挡位上,从进到出回路的完好性,其回路接触电阻应不大于出厂标准,一般小于500。有载调压开关带电前,应进行如下检查调试:(1)挡位要一致。远方指示,开关本体(顶盖上)指示,操动机构箱上的指示,必须指示同一挡位。(2)手摇调整两个完整的调压循环,从听到切换声,到看到挡位显示数对中,对摇动的圈数而言,升挡和降挡都是对称的,例如从6到7挡,从听见切换声到挡位数7挡中的手摇圈数,应当与从7到6挡时的相应圈数完全对称,最多不要超过半圈。(3)电动调整两个完整的调压循环,不应有卡涩、滑挡的现象,调到始端或终端时,闭锁装置能有效制动。(4)进行油压试验,外观无渗漏,有载调压开关储油柜的油位不得有与变压器储油柜趋平的现象。上述检查调试完好后,再与变压器一起进行有关的试验,如直流电阻、绝缘试验、变比、接线组别等,然后方可投入系统准备带电调试。做GIS交流耐压试验时应特别注意什么?答:做GIS交流耐压试验时应特别注意以下几方面:(1)规定的试验电压应施加在每一相导体和金属外壳之间,每次只能一相加压,其他相导体和接地金属外壳相连接。(2)当试验电源容量有限时,可将GIS用其内部的断路器或隔离开关分断成几个部分分别进行试验,同时不试验的部分应接地,并保证断路器断口,断口电容器或隔离开关断口上承受的电压不超过允许值。(3)GIS内部的避雷器在进行耐压试验时应与被试回路断开,GIS内部的电压互感器、电流互感器的耐压试验应参照相应的试验标准执行。怎样根据变压器直流电阻的测量结果对变压器绕组及引线情况进行判断?答:应依据下述标准进行判断:(1)1600kVA以上变压器,各相绕组电阻相互间的差别不应大于三相平均值的2%,无中性点引出的绕组,线间差别不应大于三相平均值的1.0%。(2)1600kVA及以下变压器,相间差别一般不大于三相平均值的4%,线间差别一般不大于三相平均值的2%。(3)与以前相同部位测得值(换算到同一温度下)比较其变化不应大于2%。如果测算结果超出标准规定,应查明原因。一般情况下,三相电阻不平衡的原因有以下几种:(1)分接开关接触不良。分接开关接触不良,反映在一二个分接处电阻偏大,而且三相之间不平衡。这主要是分接开关不清洁,电锻层脱落,弹簧压力不够等。固定在箱盖上的分接开关,也可能是在箱盖紧固以后,使开关受力不均造成接触不良。(2)焊接不良。由于引线和绕组焊接处接触不良,造成电阻偏大;多股并联绕组,其中有一二股没有焊上,这时一般电阻偏大较多。(3)三角形联结绕组,其中一相断线,测出的三个线端电阻都比设计值相差得多,其关系为2:1:1。此外,变压器套管的导电杆和绕组连接处,由于接触不良也会引起直流电阻增加。为什么要特别关注油中乙炔的含量?答:乙炔(C2H2)是变压器油高温裂解的产物之一。其他还有一价键的甲烷、乙烷,还有二价键的乙烯、丙烯等。乙炔是三价键的烃,温度需要高达千摄氏度以上才能生成。这表示充油设备的内部故障温度很高,多数是有电弧放电了,所以要特别重视。电力变压器装有哪些继电保护装置?答:(1)电力变压器装设的主保护有:瓦斯保护(反应变压器本体内部故障);差动保护(反应变压器各侧电流互感器以内的故障)。(2)电力变压器装设的后备保护有:复合电压闭锁过电流保护;负序电流保护;低阻抗保护;零序过电流保护;零序过电压保护;过负荷保护;超温、超压保护;冷却系统保护;其他专门保护。具体装设那种保护,要按照继电保护规程、规定,视变压器的容量、电压在电网中的作用而合理选配。变电站装设限流电抗器的主要目的是什么?答:其主要目的是:当线路或母线发生故障时,使短路电流限制在断路器允许的开断范围内,通常要限制在31.5kA以下,以便选用轻型断路器。如何填写电力设备预防性试验报告?答:填写电力设备预防性试验报告时,一般应包括下列内容:(1)按报告格式填写设备铭牌、技术规范。(2)填写试验时间、温度、湿度、压力,对变压器还要写明上层油温。(3)填写试验结果,必要时将绝缘电阻、直流电阻、介质损耗因数tanSN,所以试验变压器容量不合适。答:试验变压器额定容量略小于试验所需容量,一般不宜采用。一台SFL-20000/110变压器,电压110/10.5kV联结组别为YNd11,在110kV侧加压测零序阻抗,测量时零序电压U0=240V,零序电流I0=13.2A,试计算零序阻抗值Z0。解:YNd11变压器零序阻抗由下式计算 Z0=3U0/I0=3240/13.2=54.55()答:该变压器的零序阻抗为54.55。一台QF252型25000kW同步调相机,转子额定电压UN=182V,转子额定电流IN=375A,测量转子在膛内时的交流阻抗试验电压U=120V,回路电流I=4.52A,试计算其在试验电压下的交流阻抗值Z。解:试验电压下的交流阻抗值 Z=U/I=120/4.52=26.55()答:在试验电压下的交流阻抗为26.55。一台SFL1-10000/110的变压器,铭牌标有:P0=14kW,Pk=72kW,YNd11,试求当该变压器供给=90%额定负载且其功率因数cos为0.9(滞后)时的效率。解:已知=90%=0.9 cos=0.9 P0=14kW,Pk=72kW变压器输出有功功率P2为 P2=SNcos=0.9100000.9=8100(kW)变压器线圈损耗Pk为 Pk=2Pk=0.9272=58.32(kW)变压器输入有功功率P1为 P1=P2+P0+Pk=8100+14+58.32=8172.32(kW)=P2/P1100%=8100/8172.32100%99%答:当该变压器供给90%额定负载且其功率因数cos=0.9(滞后)时的效率为99%。设有三台三相变压器并列运行,其额定电压均为35/10.5kV,其他规范如下:(1)容量SN1:1000kVA;阻抗电压Uk1%:6.25;(2)容量SN2:1800kVA;阻抗电压Uk2%:6.6;(3)容量SN3:2400kVA;阻抗电压Uk3%:7.0;当总负载为4500kVA时,各变压器所供给的负载P1、P2、P3各是多少?解:因各变压器阻抗电压不同,每台变压器的负载分配可按下式计算 Pi=P/(P1/Uk1%+P2/Uk2%+P3/Uk3%)P1/Uki%P1=4500/(1000/6.25+1800/6.6+2400/7.0)1000/6.25 =928.3928(kVA)P2=4500/(1000/6.25+1800/6.6+2400/7.0)1800/6.6 =1582.31582(kVA)P3=4500/(1000/6.25+1800/6.6+2400/7.0)2400/7.0 =1989.31989(kVA)答:各变压器所供给的负载为:928kVA、1582kVA、1989kVA。Lb4F3002Lb4F4003Lb4F4004Lb4F3010Lb4F3012Lb4F4013Lb4F5019Lb4F5020Je4F3029Je4F3030Je4F3031为什么测量大电容量、多元件组合的电力设备绝缘的tan,对反映局部缺陷并不灵敏?答:对小电容量电力设备的整体缺陷,tan确有较高的检测力,比如纯净的变压器油耐压强度为250kV/Cm;坏的变压器油是25kV/cm;相差10倍。但测量介质损耗因数时,tan(好油)=0.01%,tan(坏油)=10%,要相差1000倍。可见介质损耗试验灵敏得多。但是,对于大容量、多元件组合的设备,如发电机、变压器、电缆、多油断路器等,实际测量的总体设备介质损耗因数tanx则是介于各个元件的介质损耗因数的最大值与最小值之间。这样,对于局部的严重缺陷,测量tanx反映并不灵敏。从而有可能使隐患发展为运行故障。鉴于上述情况,对大容量、多元件组合体的电力设备,测量tan 必须解体试验,才能从各元件的介质损耗因数值的大小上检验其局部缺陷。为什么变压器空载试验能发现铁心的缺陷?答:空载损耗基本上是铁心的磁滞损耗和涡流损失之和,仅有很小一部分是空载电流流过线圈形成的电阻损耗。因此,空载损耗的增加主要反映铁心部分的缺陷。如硅钢片间的绝缘漆质量不良,漆膜劣化造成硅钢片间短路,可能使空载损耗增大10%15%;穿心螺栓、轭铁梁等部分的绝缘损坏,都会使铁心涡流增引起局部发热,也使总的空载损耗增加。另外制造过程中选用了比设计值厚的或质量差的硅钢片以及铁心磁路对接部位缝隙过大,也会使空载损耗增大。因此,测得的损失情况可反映铁心的缺陷。为什么绝缘油内稍有一点杂质,它的击穿电压会下降很多?答:以变压器油为例来说明这种现象。在变压器油中,通常含有气泡(一种常见杂质),而变压器油的介电系数比空气高2倍多,由于电场强度与介电常数是成反比的,再加上气泡使其周围电场畸变,所以气泡中内部电场强度也比变压器油髙2倍多,气泡周边的电场强度更髙了。而气体的耐电强度比变压器油本来就低得多。所以,在变压器油中的气泡就很容易游离。气泡游离之后,产生的带电粒子再撞击油的分子,油的分子又分解出气体,由于这种连锁反应或称恶性循环,气体增长将越来越快,最后气泡就会在变压器油中沿电场方向排列成行,最终导致击穿。如果变压器油中含有水滴,特别是含有带水分的纤维(棉纱或纸类),对绝缘油的绝缘强度影响最为严重。杂质虽少,但由于会发生连锁反应并可以构成贯通性缺陷,所以会使绝缘油的放电电压下降很多。SF6气体中混有水分有何危害?答:SF6气体中混有水分,造成的危害有两个方面:(1)水分引起化学腐蚀,干燥的SF6气体是非常稳定的,在温度低于500时一般不会自行分解,但是在水分较多时,200以上就可能产生水解:2SF6+6H2O2SO2+12HF+O2,生成物中的HF具有很强的腐蚀性,且焉对生物肌体有强烈腐蚀的剧毒物,SO2遇水生成硫酸,也有腐蚀性。水分的危险,更重要的是在电弧作用下,SF6分解过程中的反应。在反应中的最后生成物中有SOF2、SO2F4、SOF4、SF4和HF,都是有毒气体。(2)水分对绝缘的危害。水分的凝结对沿面绝缘也是有害的,通常气体中混杂的水分是以水蒸气形式存在,在温度降低时可能凝结成露水附着在零件表面,在绝缘件表面可能产生沿面放电(闪络)而引起事故。为什么变压器的二次电流变化时,一次电流也随着变化?答:变压器负载(变压器二次侧接上负载)时,二次侧有了电流2,该电流建立的二次磁动势式2=2N2也作用于主磁路上,它会使主磁通少发生改变,电动势E1也随之发生改变,从而打破了原来的平衡状态,而在外施电压U1不变的前提下,主磁通应不变(因U1E1),因此,由I1建立的一次磁动势和二次磁动势的合成磁动势所产生的主磁通将仍保持原来的值,所以二次电流变化,一次电流也随着变化。真空断路器灭弧原理是什么?答:真空断路器的灭弧原理是:同任何一种髙压开关一样,熄灭电弧都要靠灭弧室。灭弧室是髙压开关的心脏。当开关的动触头和静触头分开的时候,在高电场的作用下,触头周围的介质粒子发生电离、热游离、碰撞游离,从而产生电弧。如果动、静触头处于绝对真空之中,当触头开断时由于没有任何物质存在,也就不会产生电弧,电路就很容易分断了。但是绝对真空是不存在的,人们只能制造出相当高的真空度。真空断路器的灭弧室的真空度已做到1.310-21.310-4Pa(10-410-6mm汞柱)以上,在这种高真空中,电弧所产生的微量离子和金属蒸汽会极快地扩散,从而受到强烈的冷却作用,一旦电流过零熄弧后,真空间隙介电强度恢复速度也极快,从而使电弧不再重燃。这就是真空断路器利用高真空来熄灭电弧并维持极间绝缘的基本原理。工频耐压试验接线中球隙及保护电阻有什么作用?答:在现场对电气设备Cx进行工频耐压试验,常按图F-1接线(R1为保护电阻,R2为球隙保护电阻,F为球隙)。球隙由一对铜球构成,并联在被试品CX上,其击穿电压为被试品耐压值的1.11.2倍,接上被试品进行加压试验过程中,当因误操作或其他原因出现过电压时球隙就放电,避免被试品因过电压而损坏。当球隙放电时,若流过的电流较大,会使铜球烧坏,因此在球隙上串一电阻R2(按1/v来选)以减少流过球隙的电流。R2还有一个重要作用,就是起阻尼作用,在加压试验中,如球隙击穿放电,电源被自动断开后,由于被试品Cx(相当于一个电容器)已充电,因此电容中的电能通过连线和球隙及大地形成回路(见图F-1)放电。因为连线中存在电感L,所以电容中的电能CU2/2,转为电感中的磁能LI2/2,电能与磁能之间的变换会形成振荡,可能产生过电压,损坏被试品,串上R2后可使振荡很快衰减下来,降低振荡过电压,因此,R2也称阻尼电阻。R1的作用是当被试品Cx击穿时,限制试验变压器输出电流,限制电磁振荡过电压,避免损坏仪器设备。在工频耐压试验中,被试品局部击穿,为什么有时会产生过电压?如何限制过电压?答:若被试品是较复杂的绝缘结构,可认为是几个串联电容,绝缘局部击穿就是其中一个电容被短接放电,其等值电路如图F-2所示。图F-2中E为归算到试验变压器高压侧的电源电动势,L为试验装置漏抗。当一个电容击穿,它的电压迅速降到零,无论此部分绝缘强度是否自动恢复,被试品未击穿部分所分布的电压已低于电源电动势,电源就要对被试品充电,使其电压再上升。这时,试验装置的漏抗和被试品电容形成振荡回路,使被试品电压超过高压绕组的电压,电路里接有保护电阻,一般情况下,可限制这种过电压。但试验装置漏抗很大时,就不足以阻尼这种振荡。这种过电压一般不高,但电压等级较高的试验变压器绝缘裕度也不大,当它工作在接近额定电压时,这种过电压可能对它有危险,甚至击穿被试品。一般被试品并联保护球隙,当出现过电压时,保护球隙击穿,限制电压升髙。为什么用绝缘电阻表测量大容量绝缘良好设备的绝缘电阻时,其数值随时间延长而愈来愈高?答:用绝缘电阻表测量绝缘电阻实际上是给绝缘物上加上一个直流电压,在此电压作用下,绝缘物中产生一个电流i,所测得的绝缘电阻R1=U/i。由研究和试验分析得知,在绝缘物上加直流后,产生的总电流i由三部分组成:电导电流、电容电流和吸收电流。测量绝缘电阻时,由于绝缘电阻表电压线圈的电压是固定的,而流过绝缘电阻表电流线圈的电流随时间的延长而变小,故兆欧表反映出来的电阻值愈来愈髙。设备容量愈大,吸收电流和电容电流愈大,绝缘电阻随时间升高的现象就愈显著。为什么要测量电力设备的吸收比?答:对电容量比较大的电力设备,在用绝缘电阻表测其绝缘电阻时,把绝缘电阻在两个时间下读数的比值,称为吸收比。按规定吸收比是指60s与15s时绝缘电阻读数的比值,它用下式表示 K=R60/R15测量吸收比可以判断电力设备的绝缘是否受潮,这是因为绝缘材料干燥时,泄漏电流成分很小,绝缘电阻由充电电流所决定。在摇到15s时,充电电流仍比较大,于是这时的绝缘电阻R15就比较小;摇到60s时,根据绝缘材料的吸收特性,这时的充电电流已经衰减,绝缘电阻R60就比较大,所以吸收比就比较大。而绝缘受潮时,泄漏电流分量就大大地增加,随时间变化的充电电流影响就比较小,这时泄漏电流和摇的时间关系不明显,这样R60和R15就很接近,换言之,吸收比就降低了。这样,通过所测得的吸收比的数值,可以初步判断电力设备的绝缘受潮。吸收比试验适用于电机和变压器等电容量较大的设备,其判据是,如绝缘没有受潮K1.3。而对于容量很小的设备(如绝缘子),摇绝缘电阻只需几秒钟的时间,绝缘电阻的读数即稳定下来,不再上升,没有吸收现象。因此,对电容量很小的电力设备,就用不着做吸收比试验了。测量吸收比时,应注意记录时间的误差,应准确或自动记录15s和60s的时间。对大容量试品,国内外有关规程规定可用极化指数R10min/R1min来代替吸收比试验。对电力设备进行绝缘强度试验有什么重要意义?答:电力设备在正常的运行过程中,不仅要承受额定电压的长期作用,还要耐受各种过电压,如工频过电压、雷电过电压、操作过电压。为了考核设备承受过电压的能力,人为模拟各种过电压,对设备的绝缘进行试验以检验其承受能力。这就是所谓绝缘强度试验,亦称耐压试验。为了简化,现场常用等效的交、直流耐压来代替试验设备较为复杂的冲击试验,同时也考核了设备在工作电压下的绝缘裕度。
展开阅读全文