资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,*,Slide,*,WELCOME,欢 迎,Introduction of Pluvia,GEBERIT Pluvia Rain Drainage System Introduction,吉博力Pluvia屋面雨水排放系统介绍,Water水,Air空气,Conventional system传统式系统,Only water只有水,Siphonic system虹吸系统,最大流速可达10m/s,Pluvia History,From a family company to the leader of plumbing company,especially on Pluvia,1874,1973,2003,从一个家族企业发展到现在的管道行业的领先者,尤其在虹吸雨水系统方面,1956,Start of Pluvia,7,+New type Outlet,Start,to use HDPE,Foundation of,Geberit,434,88,235,122,Sales of Pluvia System in Geberit Group,Building Drainage,Systems,建筑排水系统,(含虹吸雨水排放系统),Sales of Geberit Group in 2002:MRMB 9000,吉博力集团2002年销售:90亿人民币,Pluvia System:15%,虹吸系统占,15%,As the system supplier,Geberit give the completed products and service,作为系统供应商,吉博力提供完整的产品系列和服务,Company,introduction,Products and Service Geberit can supply,Geberit support吉博力的支持,Geberit Siphonic Outlets,吉博力虹吸式雨水斗,Pluvia DLS software虹吸系统计算软件,Geberit special HDPE drainage system,吉博力专用HDPE排水管道系统,Geberit Fasten System,吉博力固定系统,Technical consultants技术咨询,Geberit Siphonic Outlets,Type 1,:112 l/s,1型雨水斗,流量:112升/秒,Fit for All kinds of Roof适用于任何类型的屋面,Material:PP/HDPE,材质:聚丙烯/高密度聚乙烯,Size of Connecting Pipe:,56,连接管尺寸:,56,Maximum damming height:32mm,最大斗前水深:32mm,12 l/s type Siphonic Outlets,359.551.00.1,(不含接触片,需另外配接触片),359.571.00.1,(含520 x520不锈钢接触片)粘接,适用于沥青防水材料类型的混凝土平屋面,适用于不知防水材料类型的混凝土平屋面,配359.551.00.1的接触片(320 x320),359.554,不锈钢,359.555,铜质,359.556,铝质,以上适用于金属屋面,配359.551.00.1的接触片(520 x520),359.560,不锈钢,以上适用于混凝土屋面,12 l/s type Siphonic Outlets,359.636.00.1,(含320 x320,不锈钢,接触片)焊接,适用于不锈钢天沟的屋面,359.637.00.1,(含320 x320,铜质,接触片)焊接,适用于铜质天沟的屋面,359.638.00.1,(含320 x320,铝质,接触片)焊接,适用于铝质天沟的屋面,Geberit Siphonic Outlets,Type 2,:825 l/s,2型雨水斗,流量:825升/秒,Fit for Bitumen Flat or Stainless Gutter Roof 适用于沥青防水层混凝土或不锈钢天沟屋面,Material:,Peraluman/HDPE,材质:铝锰合金/高密度聚乙烯,Size of Connecting Pipe:90连接管尺寸:90,Maximum damming height:55mm,最大斗前水深:55mm,25 l/s type Siphonic Outlets,359.573.00.1,(含520 x520不锈钢接触片)粘接,适用于沥青防水材料类型的混凝土平屋面,359.544.00.1,(含320 x320,不锈钢,接触片)焊接,适用于不锈钢材质天沟的屋面,25 l/s type Siphonic Outlets,Fit for Any other material Roof need special treatment,其它材质的屋面装大斗,需特别处理,例如上图:,Requirment of Overflow,中国给排水规范规定:溢流口同雨水系统的排水量之和不小于重现期为50年的暴雨强度。,即:溢流量 50年的暴雨强度雨水系统的设计排水量,溢流口数量溢流量/单个溢流口排水量,一般情况下,天沟的溢流口设在天沟两端,如计算的溢流口数量大于2,需考虑用溢流管来实现溢流;在设置溢流口出现困难时,也可考虑溢流管来代替溢流口,甚至考虑另设一套虹吸溢流装置来保证系统的安全性。,Easy Way to settle the Gutter and Overflow,溢流口,至少450,至少350,至少50,至少50,大斗至少:110,小斗至少:80,单位:mm,大斗至少:150,小斗至少:150,吉博力天沟,溢流尺寸图,溢流口高度,天沟宽度,天沟高度,排水量,升/秒,虹吸系统,必需,设置溢流装置,以确,保系统的安全性,溢流装置的设置,应充分考虑高效的原则。,Draft settle of the Gutter and Overflow:,查表初定天沟和溢流口尺寸,Detail Requirment of Gutter,Calculation of the Gutter:,天沟的计算(满宁公式):,确定同一条天沟内的最大排水量Q,1,确定允许的天沟尺寸:宽b和高H,然后计算其流通面积S=bxH,根据满宁公式确定其天沟的流速:,v=1/nxR,2/3,xI,1/2,计算单位:IU,n:根据天沟材料粗糙度确定,一般小于0.025,可取0.025,R:水力半径,矩形R=bxH/(b+2xH),I:天沟的坡度,一般可取0.005,验算实际排水量Q,2,是否大于其最大排水量,如是即可。,Q,2,=Sxv,Q,1,Requirment of Overflow,Calculation the flow quantity of the Single Overflow:,单个溢流口排水量的计算:,根据溢流口流量公式确定其单个溢流口排量:,q=mxbx(2xg),1/2,xH,1,3/2,计算单位:IU,m:流量系数,一般可取320,b:溢流口宽度,g:重力加速度,一般取9.81,H,1,:口前堰上水深,Connection to the Roof,(1),(2),(4),(3),(5),(6),沥青屋面雨水斗的防水处理,Fasten System of Pluvia,方钢,M10螺杆,三角,楔,方钢夹,虹吸管卡,方钢连接夹,吉博力虹吸系统固定装置:,Fasten System of Pluvia,横管固定系统各点间距表,Fasten System of Pluvia,横管固定系统(不采用方钢)各点间距表,Fasten System of Pluvia,方钢,方钢连接夹,方钢夹,方钢角部连接夹,虹吸管卡,三角,楔,Fasten System of Pluvia,固定点连接方法,立管固定系统各点间距表,检修口的设置没有特别要求,考虑到虹吸系统的自净功能,原则上不需要设置检修口,但根据中国给排水习惯做法,在立管上离底楼低平上一米处设置检修口。,Manhole of Pluvia,Near the Outlets,在雨水斗处,Pipe routing of Pluvia System,虹吸系统的管道走向,在雨水斗处宜走一段横管,如图所示,主要考虑:,增加管道的扰性,减小对建筑的影响。,方便方钢的使用,使整个系统的方钢系统连为整体。,Pipe routing of Pluvia System,Layout of these Outlets,雨水斗的布置,雨水斗的布置应尽可能均匀,以减小因不均匀布置引起的对天沟尺寸的要求。,在一些雨水斗不能均匀布置的场所,应充分考虑天沟的尺寸适当放大。,相邻两个雨水斗之间距离不大于20m。,溢流口的布置不宜过多,以方便工程的实际操作。,雨水斗的布置对天沟的影响,溢流口的布置对天沟的影响,Q,max,Pipe routing of Pluvia System,Stack pipe of Pluvia system,立管的布置,虹吸系统的管道走向,立管的布置原则:,最好布置在管道井内,如不行宜布置在楼梯间等偏僻的角落。,尽可能同各雨水斗的距离近一些,主要考虑经济性问题。,Pipe routing of Pluvia System,Underground pipe of Pluvia,地下埋管的布置,虹吸系统的管道走向,地下埋管,的布置原则:,尽可能布置得短一些,管径不宜过大,不光是经济上得考虑,如管径过大,会演变成重力系统,需要一定的管坡度。,出口流速宜控制在小于34米/秒,过大会影响以后的重力系统。,过渡的水井宜用混凝土制成,连接的重力系统需按传统给排水系统设计,以确定可以排放虹吸系统的排雨量。,Pluvia,虹吸式,Conventional,传统重力式,Pipe routing of Pluvia System,Pipes penetrating through extension seams,管道穿越伸缩缝,1.建筑12.建筑23.伸缩缝,4.吉博力方钢5.吉博力管道6.固定管卡,预期S吉博力管径 伸缩腿长,20-40mm125-160/200-3151.0m/1.0m,40-60mm125-160/200-3151.0m/1.5m,60-80mm125-160/200-3151.5m/1.7m,S1=,S+10(mm),S2=0,;,DL(伸缩腿长)10*,S*,Otherness Sales between Geberit and these competitors,The Characteristic of Geberit Pluvia system:,吉博力Pluvia系统的特点:,具有30多年的实际操作经验,是给排水行业的市场领导者,占有垄断性的市场份额。,采用独特的吉博力强制式虹吸雨水斗,有气液分离装置,且已发展到了第8代,是真正意义上的虹吸系统,采用特有双相流方式计算,过程中不光考虑管道的延程阻力,也考虑了局部阻力,实现了精确计算,且具备国际权威机构对系统的认证。,在技术上扫清了采用具备了多种优势的HDPE管道的障碍,坚持采用唯一专用HDPE管材。,欧洲行业标准的制定者之一,现在中国帮助制订中国行业标准,提高行业质量。,The control of Pluvia calculation,How to control the calculation of Pluvia system?(1),如何控制Pluvia系统的计算?(1),控制雨水斗的排水量,首先根据项目选雨水斗型号,根据雨水斗数量确定单个雨水斗的排量,假定每个雨水斗的排量是相等的,在计算后验证实际的排量同假定的排量比较,在一定范围内可以被认为是许可的。(泰
展开阅读全文