《福特公司APQP教程》PPT课件.ppt

上传人:za****8 文档编号:13501321 上传时间:2020-06-19 格式:PPT 页数:44 大小:2.83MB
返回 下载 相关 举报
《福特公司APQP教程》PPT课件.ppt_第1页
第1页 / 共44页
《福特公司APQP教程》PPT课件.ppt_第2页
第2页 / 共44页
《福特公司APQP教程》PPT课件.ppt_第3页
第3页 / 共44页
点击查看更多>>
资源描述
1,Use of Ford APQP Status Report,Tong Lei Supplier Technical Assistance Ford Motor Company,2,Use of Ford APQP Status Report,APQP Overview Introduction to Ford APQP Status Reporting System How to use Ford APQP Status Reporting System Q issue sourcing agreement. PR Product Readiness. 2D drwgs/3D model/DFMEA received by supplier. CP Confirmation Prototype. Prototype parts built; “DV” test started. ESO Engineering Sign Off. “DV” test completed; PSW/LS PSW/Launch Sign. PSW and functional sign-off completed. SJ1 Supplier Job 1. Supplier ships out first production shipment. IPD In Plant Date. Parts received at Ford plant(s).,23,Two Systems, One Objective Flawless Launch!,APQP feeds EMLP,EMLP (Championed by Ford PD),APQP (Championed by Supplier),24,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,APQP for EM Re-sourcing uses 7 EMLP milestones (for re-sourcing programs); APQP v3.2 uses 12 FPDS milestones (for new programs).,25,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,FPDS Milestones Remain for Reference,EMLP Milestones Added,26,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,APQP for EM Re-sourcing uses 7 EMLP milestones (for re-sourcing programs); APQP v3.2 uses 12 FPDS milestones (for new programs). APQP for EM eliminates New Program specific requirements, which are not required for Re-sourcing Programs, from APQP v3.2. Maintains original APQP requirements as guideline.,27,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,Eliminates New Program specific requirements,Maintains original APQP requirements as guideline,28,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,APQP for EM Re-sourcing uses 7 EMLP milestones (for re-sourcing programs); APQP v3.2 uses 12 FPDS milestones (for new programs). APQP for EM eliminates New Program specific requirements, which are not required for Re-sourcing Programs, from APQP v3.2. Maintains original APQP requirements as guideline. Checklist includes additional EMLP unique Supplier responsible requirements for the 23 elements. (At bottom of the checklist for each element.),29,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,Additional EMLP unique Supplier responsible requirements,30,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,APQP for EM Re-sourcing uses 7 EMLP milestones (for re-sourcing programs); APQP v3.2 uses 12 FPDS milestones (for new programs). APQP for EM eliminates New Program specific requirements, which are not required for Re-sourcing Programs, from APQP v3.2. Maintains original APQP requirements as guideline. Checklist includes additional EMLP unique Supplier responsible requirements for the 23 elements. (At bottom of the checklist for each element.) Worksheet of “Action Plan” has been added to APQP for EM, to reduce “copies and pastes” of action plans from 23 elements to the summary sheet.,31,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,Sheet of “Action Plan” has been added.,32,APQP for Emerging Market Re-sourcing vs. Ford APQP v3.2,APQP for EM Re-sourcing uses 7 EMLP milestones (for re-sourcing programs); APQP v3.2 uses 12 FPDS milestones (for new programs). APQP for EM eliminates New Program specific requirements, which are not required for Re-sourcing Programs, from APQP v3.2. Maintains original APQP requirements as guideline. Checklist includes additional EMLP unique Supplier responsible requirements for the 23 elements. (At bottom of the checklist for each element.) Worksheet of “Action Plan” has been added to APQP for EM, to reduce “copies and pastes” of action plans from 23 elements to the summary sheet. For forward model (new) programs, Ford APQP v3.2 should be used.,33,Complete APQP Status Report For EM Re-sourcing programs,Complete Information Sheet,Input milestone dates. Should be same as timing plan.,Input Part Number and PPAP information.,Input team information, for both supplier and Ford.,Input program change history, if any.,34,Complete APQP Status Report For EM Re-sourcing programs - continue,Complete Program Information on sheet of “APQP Status Report (linked)”.,35,Complete APQP Status Report For EM Re-sourcing programs - continue,Review status of 23 elements. Next slide uses status review of element 11, drawing and specs, at PR as an example.,36,Sample Check sheet at PR,Light Gray shaded cells: Review expectation at these milestones.,If R or Y, this issue requires corrective action,If R or Y, review at next milestone (until its G), even if “Finish Target” date is passed.,Overall status is worst rating of all expectations. Manual input is NOT required.,Record identified issue and corrective action here.,Status Can be updated continuously until Milestone Date is met,Prior Milestone Status is Frozen,Input actual start and finish dates for each expectation.,37,Rating and Assessment G/Y/R Status,38,Complete APQP Status Report For EM Re-sourcing programs - continue,Complete the summary sheet on “APQP Status Report (linked)”.,Auto-linked to the overall status of the checksheet for this element.,Overall status is worst rating of all elements. Manual input is NOT required.,39,Complete APQP Status Report For EM Re-sourcing programs - continue,Complete action plan on summary sheet.,Do not input action plans on the bottom part of “APQP Status Report (linked)”.,40,Complete APQP Status Report For EM Re-sourcing programs - continue,Complete action plan on summary sheet - continue.,Header information is linked from “APQP Status Report (linked)” sheet.,Copy and paste action plans for all R and Y issues from 23 elements.,Input Element #.,41,APQP Status Report,Supplier must submit Status Report to the CSO STA every month, and two weeks before each milestone. STA Site Engineer verifies supplier APQP status and report-outs meet milestone timing. Ford Cross functional team must hold regular APQP reviews (minimum at each milestones) with Supplier to evaluate overall program health. Supplier must maintain evidence book for each element. Submit supporting documentation upon request.,42,Use of Ford APQP Status Report,Q&A,43,APQP Reference Information,Obtain a copy of APQP Status Reporting System for EM from your STA. Download APQP Status Reporting Guideline from FSN Website at: or the Ford Intranet at (for Ford employee only): Ford APQP Status Report v3.2 (for new programs) can also be obtained by using above links.,44,Use of Ford APQP Status Report,Thank You!,
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 图纸专区 > 课件教案


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!