bs英国标准】bs en 617547 fibre optic interconnecting devices and passive components — fibre

上传人:ra****d 文档编号:117046187 上传时间:2022-07-07 格式:DOC 页数:31 大小:2.08MB
返回 下载 相关 举报
bs英国标准】bs en 617547 fibre optic interconnecting devices and passive components — fibre_第1页
第1页 / 共31页
bs英国标准】bs en 617547 fibre optic interconnecting devices and passive components — fibre_第2页
第2页 / 共31页
bs英国标准】bs en 617547 fibre optic interconnecting devices and passive components — fibre_第3页
第3页 / 共31页
点击查看更多>>
资源描述
BRITISH STANDARDBS EN61754-7:2008Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7: Type MPO connector familyICS 33.180.20 BS EN 61754-7:2008National forewordThis British Standard is the UK implementation of EN 61754-7:2008. It is identical to IEC 61754-7:2008. It supersedes BS EN 61754-7:2005 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authorityStrategy Committee on 31 October 2008 BSI 2008ISBN 978 0 580 57566 2Amendments/corrigenda issued since publicationDateCommentsEUROPEAN STANDARDEN 61754-7NORME EUROPENNEEUROPISCHE NORM June 2008 ICS 33.180.20Supersedes EN 61754-7:2005English versionFibre optic interconnecting devices and passive components - Fibre optic connector interfaces -Part 7: Type MPO connector family(IEC 61754-7:2008)Dispositifs dinterconnexionet composants passifs fibres optiques - Interfaces de connecteurspour fibres optiques -Partie 7: Famille de connecteurs de type MPO(CEI 61754-7:2008)Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter vonLichtwellenleiter-Steckverbindern - Teil 7: Steckverbinderfamilieder Bauart MPO (IEC 61754-7:2008)This European Standard was approved by CENELEC on 2008-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 61754-7:2008 EForewordThe text of document 86B/2581/CDV, future edition 3 of IEC 61754-7, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61754-7 on 2008-04-01.This European Standard supersedes EN 61754-7:2005.Specific technical changes involve the addition of an aligned key adaptor interface definition to address all existing MPO applicationsThe following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identicalnational standard or by endorsement(dop)2009-01-01 latest date by which the national standards conflictingwith the EN have to be withdrawn(dow)2011-04-01The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning MPO connectors.The IEC and CENELEC take no position concerning the evidence, validity and scope of this patent right.The holder of this patent right has assured the IEC that he/she is willing to negotiate licences under reasonable and non- discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with the IEC. Information may be obtained from:Intellectual Property Department,Nippon Telegraph and Telephone Corporation,20-2 Nishi-shinjuku 3-Chome Shinjukuku, Tokyo 163-14, Japan.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those identified above. IEC and CENELEC shall not be held responsible for identifying any or all such patent rights.Endorsement noticeThe text of the International Standard IEC 61754-7:2008 was approved by CENELEC as a EuropeanStandard without any modification.CONTENTS1Scope . 42Description . 43Interfaces .4Figure 1 MPO connector configurations .5Figure 2 MPO female plug connector angled interface . 6Figure 3 Optical datum target location diagrams . 8Figure 4 Gauge pin. 10Figure 5 Gauge for plug. 11Figure 6 MPO male plug connector angled interface . 12Figure 7 MPO adaptor interface . 14Figure 8 MPO female plug connector flat interface . 16Figure 9 MPO male plug connector flat interface . 18Figure 10 MPO backplane housing interface . 20Figure 11 MPO printed board housing interface . 23Figure 12 MPO aligned key adaptor interface. 26Table 1 Dimensions of the MPO female plug connector angled interface . 7Table 2 Dimensions of the gauge pin . 10Table 3 Dimensions of the gauge for plug . 11Table 4 Dimensions of the MPO male plug connector angled interface . 13Table 5 Dimensions of the MPO adaptor interface . 15Table 6 Dimensions of the MPO female plug connector flat interface . 17Table 7 Dimensions of the MPO male plug connector flat interface . 19Table 8 Dimensions of the MPO backplane housing . 22Table 9 Grade . 23Table 10 Dimensions of the MPO printed board housing interface . 25Table 11 Dimensions of the MPO aligned key adaptor interface . 27FIBRE OPTIC INTERCONNECTINGDEVICES AND PASSIVE COMPONENTS FIBRE OPTIC CONNECTOR INTERFACES Part 7: Type MPO connector family1ScopeThis part of IEC 61754 defines the standard interface dimensions for type MPO family of connectors.2DescriptionThe parent connector for type MPO connector family is a multiway plug connector charac- terized by a rectangular ferrule normally 6,4 mm 2,5 mm which utilizes two pins of 0,7 mm diameter as its alignment. It is applicable to a joint of multiple fibres up to 12 fibres by arraying them between two pin-positioning holes in the ferrule. Furthermore, it is capable of joining up to24 fibres by arraying them with a two layer arrangement. The connector includes a push-pull coupling mechanism and a ferrule spring loaded in the direction of the optical axis. The connector has a single male key which may be used to orient and limit the relative position between the connector and the component to which it is mated.Connector interfaces are configured using a female plug without pins, a male plug with pins fixed and an adaptor as shown in Figure 1. The female plug is intermateable with the male plug.Moreover, connector interfaces between the female plug and the male plug are configured by applying a backplane housing and a printed board housing instead of the adaptor.3InterfacesThis standard contains the following standard interfaces:Interface 7-1:MPO female plug connector angled interface Push/pull consisting of: Interface 7-1-1 for 2 to 12 fibresInterface 7-1-2 for 16 to 24 fibresInterface 7-2:MPO male plug connector angled interface Push/pull consisting of: Interface 7-2-1 for 2 to 12 fibresInterface 7-2-2 for 16 to 24 fibresInterface 7-3:MPO adaptor interface Push/pullInterface 7-4:MPO female plug connector flat interface Push/pull consisting of: Interface 7-4-1 for 2 to 12 fibresInterface 7-4-2 for 16 to 24 fibresInterface 7-5:MPO male plug connector flat interface Push/pull consisting of: Interface 7-5-1 for 2 to 12 fibresInterface 7-5-2 for 16 to 24 fibresInterface 7-6: MPO backplane housing interface Self-retainingInterface 7-7: MPO printed board housing interface Self-retainingInterface 7-8: MPO adaptor interface Push/pull, aligned key configurationThe following standards are intermateable:Female plugs7-1-1Adaptors/housings7-3Male plugs7-2-17-1-27-37-2-27-4-17-3 and 7-87-5-17-4-27-3 and 7-87-5-27-1-17-6 and 7-77-2-17-1-27-6 and 7-77-2-27-4-17-6 and 7-77-5-17-4-27-6 and 7-77-5-2NOTE Connector interfaces among 2 to 12 fibres will intermate and will correctly align the lower defined numbers of optical datum targets. Also connector interfaces among 16 to 24 fibres will intermate and will correctly align the lower defined numbers of optical datum targets.Female plugAdaptorMale plugBackplane housingPrinted board housingIEC 1065/2000Figure 1 MPO connector configurationsZRQ PKIOAC DEFGHSJN ACABYLAACoupling sleeveMTUXPin-holesSee Figure 3ADIEC 395/08Figure 2 MPO female plug connector angled interfaceTable 1 Dimensions of the MPO female plug connector angled interfaceReferenceDimensionsNotesMinimumMaximumA C D E F G H IJ K L M N O P Q R S T UAA AB ACAD0,699 mm4,597 mm6,3 mm8,34 mm9,49 mm10,85 mm12,19 mm8,8 mm7,9 mm1,4 mm0,2 mm2,4 mm2,8 mm4,89 mm5,59 mm5,7 mm2,9 mm2,4 mm427,50,701 mm4,603 mm6,5 mm8,54 mm9,59 mm11,05 mm12,59 mm9,2 mm8,1 mm0,8 mm2,6 mm3,0 mm4,99 mm5,69 mm7,7 mm3,1 mm0,8 mm2,5 mm4545458,51234 and 5NOTE 1 Each pin-hole must accept a gauge pin as shown in Figure 4 to a depth of 5,5 mm with a maximum force of 1,7 N. In addition, two pin-holes of a plug must accept a gauge as shown in Figure 5 to a depth of 5,5 mm with a maximum force of 3,4 N.NOTE 2 Dimension C is defined as the distance between two pin-hole centres.NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is movable by a certain axial compression force, and therefore dimension I is variable. Ferrule compression force must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm.NOTE 4 Coupling sleeve must be movable by a certain axial compression force. Dimension L is given for a coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N when a position of the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the left of datum Z.NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve, when it is separate from an adaptor. W hen the coupling sleeve is moved for unlocking, a position of the coupling sleeve endface must be larger than 2,0 mm in the left direction from the datum Z.0,1250,125X0,1250,3750,375X0,1250,1250,3750,6250,8750,3750,6250,875YYYX0,1250,125Two fibresFour fibresEight fibres0,1250,3750,6250,3750,6250,8751,1250,8751,1250,1250,1250,3750,6250,8751,1251,3750,3750,6250,8751,1251,375Y YXTen fibresTwelve fibresIEC 1594/04XFigure 3 Optical datum target location diagrams (1 of 2)0,2500,2500,1250,125X0,2500,2500,3750,6250,8750,3750,6250,8750,1250,1250,3750,6250,8751,1250,3750,6250,8751,125YYXSixteen fibres0,1250,1250,2500,250Twenty fibres0,3750,6250,8751,1251,3750,3750,6250,8751,1251,375YXTwenty four fibresIEC 1595/04NOTE The optical datum target location diagram is shown in the figure. Here, datum X is defined as the line passing through two pin-hole centres, and datum Y is defined as the line perpendicular to datum X and passing through the midpoint of two pin-hole centres.Figure 3 (2 of 2)BAABBBCB0,0005IEC 1596/04Figure 4 Gauge pinTable 2 Dimensions of the gauge pinReferenceDimensionsmmNotesMinimumMaximumA BBA BBBC0,698 510,80,20,26,00,699 011,20,40,512NOTE 1 Surface roughness Rz = 0,1 m for the length of dimension BC. NOTE 2 Typical dimensions.0,001WBAADCWBBUBC0,000 5IEC 396/08Figure 5 Gauge for plugTable 3 Dimensions of the gauge for plugReferenceDimensionsmmNotesMinimumMaximumA C D UBA BBBC0,698 54,599 56,32,40,20,26,00,699 04,600 56,52,50,40,56,5For two pins, 122NOTE 1 Surface roughness Rz = 0,1 m. NOTE 2 Typical dimensions.Z0,002 WKI JACAC DEFGHABR Q PSGuide-pinO NYLAA Coupling sleeveMWGuide-pinSee Figure 3BAUBBTADCAXIEC 397/08Figure 6 MPO male plug connector angled interfaceTable 4 Dimensions of the MPO male plug connector angled interfaceReferenceDimensionsNotesMinimumMaximumA C D E F G H IJ K L M N O P Q R S T UAA AB AC AD BA BB CA0,697 mm4,597 mm6,3 mm8,34 mm9,49 mm10,85 mm12,19 mm8,8 mm7,9 mm1,4 mm0,2 mm2,4 mm2,8 mm4,89 mm5,59 mm5,7 mm2,9 mm2,4 mm427,50,2 mm0,2 mm1,6 mm0,699 mm4,603 mm6,5 mm8,54 mm9,59 mm11,05 mm12,59 mm9,2 mm8,1 mm0,8 mm2,6 mm3,0 mm4,99 mm5,69 mm7,7 mm3,1 mm0,8 mm2,5 mm4545458,50,4 mm0,5 mm3,3 mm1234 and 56NOTE 1 Each guide pin must be retained with a minimum force of 19,6 N. Surface roughness Rz must be below 0,5 m.NOTE 2 Dimension C is defined as the distance between two guide-pin centres.NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is movable by a certain axial compression force, and therefore the dimension I is variable. Ferrule compression force must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm.NOTE 4 Coupling sleeve must be movable by a certain axial compression force. Dimension L is given for a coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N when a position of the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the left of datum Z.NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve, when it is separate from an adaptor. W hen the coupling sleeve is moved for unlocking, a position of the coupling sleeve endface must be larger than 2,0 mm in the left direction from the datum Z.NOTE 6 The top shape of guide-pin may be a round shape that is symmetrical about the guide-pin axis with a minimum radius of 0,15 mm.RPOXNZISHWVAABFEBBKVAAAKeyways opposedLMSection A-ASection B-BIEC 398/08Figure 7 MPO adaptor interfaceTable 5 Dimensions of the MPO adaptor interfaceReferenceDimensions mmNotesMinimumMaximumE F H I K LM N O P R S V W XAA AB8,54 mm9,6 mm12,6 mm8,2 mm01,6 mm2,4 mm5,0 mm5,7 mm7,8 mm3,4 mm0,95 mm11,8 mm3,4 mm45458,74 mm9,7 mm8,4 mm1,39 mm0,1 mm2,0 mm2,6 mm5,1 mm5,9 mm3,6 mm1,15 mm12,2 mm48501NOTE 1 Dimension L is the distance from datum Z to a latch-ledge end. The latch-ledge end may be located to the right or to the left of datum Z.R ZQXP KI OJNACAC DEFGH SABYAA LCoupling sleeveMUPin-holesSee Figure 3IEC 399/08Figure 8 MPO female plug connector flat interfaceTable 6 Dimensions of t
展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 商业管理 > 商业计划


copyright@ 2023-2025  zhuangpeitu.com 装配图网版权所有   联系电话:18123376007

备案号:ICP2024067431-1 川公网安备51140202000466号


本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。装配图网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知装配图网,我们立即给予删除!